Precision Balance Assessment in Parkinson’s Disease: Utilizing Vision-Based 3D Pose Tracking for Pull Test Analysis

Nina Ellrich, Kasimir Niermeyer, D. Peto, Julian Decker, Urban M. Fietzek, S. Katzdobler, Günter U. Höglinger, Klaus Jahn, A. Zwergal, M. Wuehr
{"title":"Precision Balance Assessment in Parkinson’s Disease: Utilizing Vision-Based 3D Pose Tracking for Pull Test Analysis","authors":"Nina Ellrich, Kasimir Niermeyer, D. Peto, Julian Decker, Urban M. Fietzek, S. Katzdobler, Günter U. Höglinger, Klaus Jahn, A. Zwergal, M. Wuehr","doi":"10.3390/s24113673","DOIUrl":null,"url":null,"abstract":"Postural instability is a common complication in advanced Parkinson’s disease (PD) associated with recurrent falls and fall-related injuries. The test of retropulsion, consisting of a rapid balance perturbation by a pull in the backward direction, is regarded as the gold standard for evaluating postural instability in PD and is a key component of the neurological examination and clinical rating in PD (e.g., MDS-UPDRS). However, significant variability in test execution and interpretation contributes to a low intra- and inter-rater test reliability. Here, we explore the potential for objective, vision-based assessment of the pull test (vPull) using 3D pose tracking applied to single-sensor RGB-Depth recordings of clinical assessments. The initial results in a cohort of healthy individuals (n = 15) demonstrate overall excellent agreement of vPull-derived metrics with the gold standard marker-based motion capture. Subsequently, in a cohort of PD patients and controls (n = 15 each), we assessed the inter-rater reliability of vPull and analyzed PD-related impairments in postural response (including pull-to-step latency, number of steps, retropulsion angle). These quantitative metrics effectively distinguish healthy performance from and within varying degrees of postural impairment in PD. vPull shows promise for straightforward clinical implementation with the potential to enhance the sensitivity and specificity of postural instability assessment and fall risk prediction in PD.","PeriodicalId":221960,"journal":{"name":"Sensors (Basel, Switzerland)","volume":"26 7","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensors (Basel, Switzerland)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/s24113673","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Postural instability is a common complication in advanced Parkinson’s disease (PD) associated with recurrent falls and fall-related injuries. The test of retropulsion, consisting of a rapid balance perturbation by a pull in the backward direction, is regarded as the gold standard for evaluating postural instability in PD and is a key component of the neurological examination and clinical rating in PD (e.g., MDS-UPDRS). However, significant variability in test execution and interpretation contributes to a low intra- and inter-rater test reliability. Here, we explore the potential for objective, vision-based assessment of the pull test (vPull) using 3D pose tracking applied to single-sensor RGB-Depth recordings of clinical assessments. The initial results in a cohort of healthy individuals (n = 15) demonstrate overall excellent agreement of vPull-derived metrics with the gold standard marker-based motion capture. Subsequently, in a cohort of PD patients and controls (n = 15 each), we assessed the inter-rater reliability of vPull and analyzed PD-related impairments in postural response (including pull-to-step latency, number of steps, retropulsion angle). These quantitative metrics effectively distinguish healthy performance from and within varying degrees of postural impairment in PD. vPull shows promise for straightforward clinical implementation with the potential to enhance the sensitivity and specificity of postural instability assessment and fall risk prediction in PD.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
帕金森病的精准平衡评估:利用基于视觉的三维姿势跟踪进行拉力测试分析
姿势不稳定是帕金森病(PD)晚期的常见并发症,与反复跌倒和跌倒相关的伤害有关。后推力测试是通过向后拉的方式快速扰乱平衡,被认为是评估帕金森病患者姿势不稳的黄金标准,也是帕金森病神经系统检查和临床评分(如 MDS-UPDRS)的关键组成部分。然而,由于测试的执行和解释存在很大的差异,导致测试的内部和评分者之间的可靠性较低。在此,我们将三维姿势跟踪应用于临床评估的单传感器 RGB 深度记录,探索基于视觉的拉力测试(vPull)客观评估的潜力。在一组健康人(n = 15)中得出的初步结果表明,vPull 得出的指标与基于黄金标准标记的运动捕捉总体上非常吻合。随后,在一组帕金森病患者和对照组(各 15 人)中,我们评估了 vPull 的评分者间可靠性,并分析了与帕金森病相关的姿势反应障碍(包括拉到步延迟、步数、后推角度)。这些定量指标可有效区分健康表现与不同程度的帕金森病姿势障碍。vPull有望直接应用于临床,并有可能提高帕金森病姿势不稳定性评估和跌倒风险预测的灵敏度和特异性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Flexible Ammonia Gas Sensor Based on a Grafted Polyaniline Grown on a Polyethylene Terephthalate Film Investigation of Appropriate Scaling of Networks and Images for Convolutional Neural Network-Based Nerve Detection in Ultrasound-Guided Nerve Blocks EMR-HRNet: A Multi-Scale Feature Fusion Network for Landslide Segmentation from Remote Sensing Images Measuring DNI with a New Radiometer Based on an Optical Fiber and Photodiode Highly Sensitive Balloon-like Fiber Interferometer Based on Ethanol Coated for Temperature Measurement
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1