Flow-controlled expiration ventilation using a piston ventilator: effects of expiration time and speed on respiratory and pulmonary mechanics with focus on hysteresis and compliance in healthy horses.

IF 1.3 3区 农林科学 Q2 VETERINARY SCIENCES American journal of veterinary research Pub Date : 2024-06-05 DOI:10.2460/ajvr.24.02.0036
Hope F Douglas, Jerrianne Brandly, Klaus Hopster
{"title":"Flow-controlled expiration ventilation using a piston ventilator: effects of expiration time and speed on respiratory and pulmonary mechanics with focus on hysteresis and compliance in healthy horses.","authors":"Hope F Douglas, Jerrianne Brandly, Klaus Hopster","doi":"10.2460/ajvr.24.02.0036","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To investigate the effects of FLow-controlled EXpiration (FLEX) ventilation expiration time and speed on respiratory and pulmonary mechanics in anesthetized horses in dorsal recumbency.</p><p><strong>Animals: </strong>6 healthy adult research horses.</p><p><strong>Methods: </strong>In this randomized crossover experimental study, horses were anesthetized 3 times and were ventilated each time for 60 minutes using conventional volume-controlled ventilation (VCV), linear emptying of the lung over 50% of the expiratory time (FLEX50), or linear emptying of the lung over 100% of the expiratory time (FLEX100) in a randomized order. The primary outcome variables were dynamic compliance (Cdyn), hysteresis, and alveolar dead space. The data was analyzed using two-factor ANOVA. Significance was set to P < .05.</p><p><strong>Results: </strong>Horses ventilated using FLEX50 and FLEX100 showed significantly higher Cdyn and significantly lower hysteresis values compared to horses ventilated using VCV. Horses ventilated using FLEX50 had significantly lower alveolar dead space compared to horses ventilated using FLEX100 or VCV. Horses ventilated using FLEX100 had significantly lower alveolar dead space compared to VCV horses.</p><p><strong>Clinical relevance: </strong>Our results demonstrate improved Cdyn, hysteresis, and alveolar dead space in horses ventilated with either FLEX50 or FLEX100 relative to traditional VCV. The use of FLEX with a faster exhalation speed (FLEX50) offers additional respiratory advantages.</p>","PeriodicalId":7754,"journal":{"name":"American journal of veterinary research","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of veterinary research","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.2460/ajvr.24.02.0036","RegionNum":3,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To investigate the effects of FLow-controlled EXpiration (FLEX) ventilation expiration time and speed on respiratory and pulmonary mechanics in anesthetized horses in dorsal recumbency.

Animals: 6 healthy adult research horses.

Methods: In this randomized crossover experimental study, horses were anesthetized 3 times and were ventilated each time for 60 minutes using conventional volume-controlled ventilation (VCV), linear emptying of the lung over 50% of the expiratory time (FLEX50), or linear emptying of the lung over 100% of the expiratory time (FLEX100) in a randomized order. The primary outcome variables were dynamic compliance (Cdyn), hysteresis, and alveolar dead space. The data was analyzed using two-factor ANOVA. Significance was set to P < .05.

Results: Horses ventilated using FLEX50 and FLEX100 showed significantly higher Cdyn and significantly lower hysteresis values compared to horses ventilated using VCV. Horses ventilated using FLEX50 had significantly lower alveolar dead space compared to horses ventilated using FLEX100 or VCV. Horses ventilated using FLEX100 had significantly lower alveolar dead space compared to VCV horses.

Clinical relevance: Our results demonstrate improved Cdyn, hysteresis, and alveolar dead space in horses ventilated with either FLEX50 or FLEX100 relative to traditional VCV. The use of FLEX with a faster exhalation speed (FLEX50) offers additional respiratory advantages.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用活塞式呼吸机进行流量控制呼气通气:呼气时间和速度对呼吸和肺力学的影响,重点是健康马的滞后性和顺应性。
目的:研究 FLow-controlled EXpiration (FLEX) 通气呼气时间和速度对麻醉马背卧时呼吸和肺力学的影响:研究流量控制通气(FLEX)呼气时间和速度对背卧位麻醉马匹呼吸和肺力学的影响:在这项随机交叉实验研究中,对马匹进行了 3 次麻醉,并按照随机顺序使用传统的容量控制通气(VCV)、超过 50% 呼气时间的线性肺排空(FLEX50)或超过 100% 呼气时间的线性肺排空(FLEX100)进行通气,每次通气时间为 60 分钟。主要结果变量为动态顺应性(Cdyn)、滞后和肺泡死腔。数据采用双因素方差分析。显著性设定为 P < .05:结果:与使用 VCV 通气的马匹相比,使用 FLEX50 和 FLEX100 通气的马匹的 Cdyn 值明显更高,滞后值明显更低。与使用FLEX100或VCV通气的马匹相比,使用FLEX50通气的马匹肺泡死腔明显更小。与使用 VCV 通气的马匹相比,使用 FLEX100 通气的马匹肺泡死腔明显更小:我们的研究结果表明,与传统 VCV 相比,使用 FLEX50 或 FLEX100 通气的马匹的 Cdyn、滞后和肺泡死腔均有所改善。使用呼气速度更快的 FLEX(FLEX50)可带来更多的呼吸优势。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.70
自引率
10.00%
发文量
186
审稿时长
3 months
期刊介绍: The American Journal of Veterinary Research supports the collaborative exchange of information between researchers and clinicians by publishing novel research findings that bridge the gulf between basic research and clinical practice or that help to translate laboratory research and preclinical studies to the development of clinical trials and clinical practice. The journal welcomes submission of high-quality original studies and review articles in a wide range of scientific fields, including anatomy, anesthesiology, animal welfare, behavior, epidemiology, genetics, heredity, infectious disease, molecular biology, oncology, pharmacology, pathogenic mechanisms, physiology, surgery, theriogenology, toxicology, and vaccinology. Species of interest include production animals, companion animals, equids, exotic animals, birds, reptiles, and wild and marine animals. Reports of laboratory animal studies and studies involving the use of animals as experimental models of human diseases are considered only when the study results are of demonstrable benefit to the species used in the research or to another species of veterinary interest. Other fields of interest or animals species are not necessarily excluded from consideration, but such reports must focus on novel research findings. Submitted papers must make an original and substantial contribution to the veterinary medicine knowledge base; preliminary studies are not appropriate.
期刊最新文献
Effect of repeated steam sterilizations on insertional torque, torque to failure, and axial pullout strength of 3.5-mm and 2.0-mm cortical bone screws. Mineralization of equine proximal sesamoid bones precedes articular cartilage and fibrocartilaginous enthesis maturation in early postgestational development. Echocardiographic evaluation in koi carp (Cyprinus carpio) under manual restraint compared to anesthesia with isoeugenol. Rectus sheath block results in greater cranial-caudal spread whereas transversus abdominis plane block results in greater lateral spread as assessed by computed tomography in dogs. A review of the current standing of microRNA expression in canine urothelial carcinoma.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1