Nanoscale Analysis of Frozen Water by Atom Probe Tomography Using Graphene Encapsulation and Cryo-Workflows.

IF 2.9 4区 工程技术 Q3 MATERIALS SCIENCE, MULTIDISCIPLINARY Microscopy and Microanalysis Pub Date : 2024-06-21 DOI:10.1093/mam/ozae054
Florant Exertier, Levi Tegg, Adam Taylor, Julie M Cairney, Jing Fu, Ross K W Marceau
{"title":"Nanoscale Analysis of Frozen Water by Atom Probe Tomography Using Graphene Encapsulation and Cryo-Workflows.","authors":"Florant Exertier, Levi Tegg, Adam Taylor, Julie M Cairney, Jing Fu, Ross K W Marceau","doi":"10.1093/mam/ozae054","DOIUrl":null,"url":null,"abstract":"<p><p>There has been an increasing interest in atom probe tomography (APT) to characterize hydrated and biological materials. A major benefit of APT compared to microscopy techniques more commonly used in biology is its combination of outstanding three-dimensional (3D) spatial resolution and mass sensitivity. APT has already been successfully used to characterize biominerals, revealing key structural information at the atomic scale, however there are many challenges inherent to the analysis of soft hydrated materials. New preparation protocols, often involving specimen preparation and transfer at cryogenic temperature, enable APT analysis of hydrated materials and have the potential to enable 3D atomic scale characterization of biological materials in the near-native hydrated state. In this study, samples of pure water at the tips of tungsten needle specimens were prepared at room temperature by graphene encapsulation. A comparative study was conducted where specimens were transferred at either room temperature or cryo-temperature and analyzed by APT by varying the flight path and pulsing mode. The differences between the analysis workflows are presented along with recommendations for future studies, and the compatibility between graphene coating and cryogenic workflows is demonstrated.</p>","PeriodicalId":18625,"journal":{"name":"Microscopy and Microanalysis","volume":" ","pages":""},"PeriodicalIF":2.9000,"publicationDate":"2024-06-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microscopy and Microanalysis","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1093/mam/ozae054","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MATERIALS SCIENCE, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

There has been an increasing interest in atom probe tomography (APT) to characterize hydrated and biological materials. A major benefit of APT compared to microscopy techniques more commonly used in biology is its combination of outstanding three-dimensional (3D) spatial resolution and mass sensitivity. APT has already been successfully used to characterize biominerals, revealing key structural information at the atomic scale, however there are many challenges inherent to the analysis of soft hydrated materials. New preparation protocols, often involving specimen preparation and transfer at cryogenic temperature, enable APT analysis of hydrated materials and have the potential to enable 3D atomic scale characterization of biological materials in the near-native hydrated state. In this study, samples of pure water at the tips of tungsten needle specimens were prepared at room temperature by graphene encapsulation. A comparative study was conducted where specimens were transferred at either room temperature or cryo-temperature and analyzed by APT by varying the flight path and pulsing mode. The differences between the analysis workflows are presented along with recommendations for future studies, and the compatibility between graphene coating and cryogenic workflows is demonstrated.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用石墨烯封装和低温工作流,通过原子探针断层扫描技术对冷冻水进行纳米级分析。
人们对原子探针断层成像技术(APT)用于表征水合材料和生物材料的兴趣与日俱增。与生物学中更常用的显微镜技术相比,原子探针断层成像技术的一大优势在于它结合了出色的三维(3D)空间分辨率和质量灵敏度。APT 已成功用于表征生物矿物,揭示了原子尺度上的关键结构信息,但在分析水合软材料方面还存在许多固有的挑战。新的制备规程通常涉及试样制备和低温转移,可实现水合材料的 APT 分析,并有可能实现近原生水合状态生物材料的三维原子尺度表征。在本研究中,通过石墨烯封装技术在室温下制备了钨针试样顶端的纯水样本。通过改变飞行路径和脉冲模式,在室温或低温下转移试样并用 APT 进行分析。报告介绍了分析工作流程之间的差异以及对未来研究的建议,并展示了石墨烯涂层与低温工作流程之间的兼容性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Microscopy and Microanalysis
Microscopy and Microanalysis 工程技术-材料科学:综合
CiteScore
1.10
自引率
10.70%
发文量
1391
审稿时长
6 months
期刊介绍: Microscopy and Microanalysis publishes original research papers in the fields of microscopy, imaging, and compositional analysis. This distinguished international forum is intended for microscopists in both biology and materials science. The journal provides significant articles that describe new and existing techniques and instrumentation, as well as the applications of these to the imaging and analysis of microstructure. Microscopy and Microanalysis also includes review articles, letters to the editor, and book reviews.
期刊最新文献
Retraction of: Automated Tools to Advance High-Resolution Imaging in Liquid. Retraction of: Structural Insights of the SARS-CoV-2 Nucleocapsid Protein: Implications for the Inner-workings of Rapid Antigen Tests. A Novel Self-Opening Transfer Shuttle for the Transfer of Air-Sensitive Sample to Scanning Electron Microscopy. Continuity of Mitochondrial Budding: Insights from BS-C-1 Cells by In Situ Cryo-electron Tomography. Direct Evidence of Anomalous Peierls Transition-Induced Charge Density Wave Order at Room Temperature in Metallic NaRu2O4.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1