Complications of Implantation of Cardiovascular Implantable Electronic Device

Ormir Shurdha, Endri Hasimi, Mirald Gina
{"title":"Complications of Implantation of Cardiovascular Implantable Electronic Device","authors":"Ormir Shurdha, Endri Hasimi, Mirald Gina","doi":"10.32391/ajtes.v8i2.403","DOIUrl":null,"url":null,"abstract":"Introduction: Cardiovascular implantable electronic devices (CIEDs), including pacemakers, implantable cardioverter-defibrillators (ICDs), and cardiac resynchronization therapy (CRT) devices, are crucial for managing various cardiac conditions. However, their implantation is associated with a range of potential complications. \nThis article investigates the incidence, types, and risk factors of complications arising from CIED implantation. \nAround 180.000 pacemakers are implanted every year in the USA [1]. Keeping in mind that pacemakers are implanted mainly in the elderly, the increasing proportion of this age group translates to a progressive increase in yearly implantations. \nA review of pacemakers implanted in adults shows an age interval of 69-86 years old, with 30-40% of patients >80 years old [2,3]. \nIn a case series article, 218 patients were included in those undergoing permanent pacemaker implantation in the UHC \"Mother Theresa\" Tirana. \nData were retrospectively collected from patients who underwent CIED implantation. The primary complications assessed included infection, lead dislodgement, device malfunction, hematoma, and vascular complications. Statistical analysis was performed to identify significant risk factors associated with these complications. \nConclusions: This article underscores the importance of meticulous procedural techniques, thorough patient assessment, and post-implantation monitoring to minimize the risks associated with CIED implantation. Enhanced understanding of these complications can lead to improved patient outcomes and the development of strategies to mitigate risks in clinical practice. \nKeywords: permanent pacemaker implantation (ppm), cardiac implantable electronic device (cied), long-term care, postoperative complication","PeriodicalId":32905,"journal":{"name":"Albanian Journal of Trauma and Emergency Surgery","volume":"77 26","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-07-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Albanian Journal of Trauma and Emergency Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.32391/ajtes.v8i2.403","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Cardiovascular implantable electronic devices (CIEDs), including pacemakers, implantable cardioverter-defibrillators (ICDs), and cardiac resynchronization therapy (CRT) devices, are crucial for managing various cardiac conditions. However, their implantation is associated with a range of potential complications. This article investigates the incidence, types, and risk factors of complications arising from CIED implantation. Around 180.000 pacemakers are implanted every year in the USA [1]. Keeping in mind that pacemakers are implanted mainly in the elderly, the increasing proportion of this age group translates to a progressive increase in yearly implantations. A review of pacemakers implanted in adults shows an age interval of 69-86 years old, with 30-40% of patients >80 years old [2,3]. In a case series article, 218 patients were included in those undergoing permanent pacemaker implantation in the UHC "Mother Theresa" Tirana. Data were retrospectively collected from patients who underwent CIED implantation. The primary complications assessed included infection, lead dislodgement, device malfunction, hematoma, and vascular complications. Statistical analysis was performed to identify significant risk factors associated with these complications. Conclusions: This article underscores the importance of meticulous procedural techniques, thorough patient assessment, and post-implantation monitoring to minimize the risks associated with CIED implantation. Enhanced understanding of these complications can lead to improved patient outcomes and the development of strategies to mitigate risks in clinical practice. Keywords: permanent pacemaker implantation (ppm), cardiac implantable electronic device (cied), long-term care, postoperative complication
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
植入心血管植入式电子设备的并发症
导言:心血管植入式电子设备(CIED),包括起搏器、植入式心律转复除颤器(ICD)和心脏再同步化治疗(CRT)设备,对于控制各种心脏疾病至关重要。然而,这些设备的植入与一系列潜在并发症有关。本文调查了 CIED 植入并发症的发生率、类型和风险因素。美国每年植入约 180,000 个心脏起搏器[1]。考虑到心脏起搏器主要是为老年人植入的,这一年龄组所占比例的增加意味着每年植入的心脏起搏器数量也在逐渐增加。对成人心脏起搏器植入情况的回顾显示,植入者的年龄介于 69-86 岁之间,其中 30-40% 的患者年龄大于 80 岁[2,3]。在一篇病例系列文章中,地拉那 "特蕾莎修女 "联合医疗中心的 218 名患者接受了永久性心脏起搏器植入手术。文章回顾性地收集了接受 CIED 植入术的患者的数据。评估的主要并发症包括感染、导联脱落、装置故障、血肿和血管并发症。研究人员进行了统计分析,以确定与这些并发症相关的重要风险因素。结论:这篇文章强调了一丝不苟的手术技术、全面的患者评估和植入后监测对最大限度降低 CIED 植入相关风险的重要性。加强对这些并发症的了解可以改善患者的预后,并在临床实践中制定降低风险的策略。关键词:永久起搏器植入术(PPM)、心脏植入式电子设备(CIED)、长期护理、术后并发症
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
38
审稿时长
8 weeks
期刊最新文献
The Liver Abscess after Laparoscopic Cholecystectomy. A Case Report. Study Size Impact on Accuracy of the Worldwide Incidence of Pilonidal Sinus Management of Periarthritis Shoulder by Intra-Articular Steroid Injection and Shoulder Joint Manipulation Complications of Implantation of Cardiovascular Implantable Electronic Device Wernicke’s Encephalopathy from Hyperemesis Gravidarum. A Case Report
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1