Comparison of lung volumes measured with computed tomography and whole-body plethysmography - a systematic review.

IF 1.8 Q3 RESPIRATORY SYSTEM European Clinical Respiratory Journal Pub Date : 2024-07-29 eCollection Date: 2024-01-01 DOI:10.1080/20018525.2024.2381898
Høgni Janus Bjarnason Olsen, Jann Mortensen
{"title":"Comparison of lung volumes measured with computed tomography and whole-body plethysmography - a systematic review.","authors":"Høgni Janus Bjarnason Olsen, Jann Mortensen","doi":"10.1080/20018525.2024.2381898","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Whole-body plethysmography is the preferred method for measuring the static lung volumes: total lung capacity (TLC), functional residual capacity (FRC) and residual volume (RV), as it also incorporates trapped gas - a common finding in chronic obstructive pulmonary disease (COPD). Quantitative computed tomography (CT) is a promising alternative to plethysmography, which can be challenging to perform for patients with severely impaired lung function. The present systematic review explores the agreement between lung volumes measured by plethysmography and CT, as well as the attempts being made to optimize alignment between these two methods.</p><p><strong>Methods: </strong>A literature search was performed on the PubMed database using the block search strategy. Articles were included if they provided both CT based and plethysmography based TLC. Risk of bias was evaluated using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) checklist.</p><p><strong>Results: </strong>22 articles were included. On average, CT-derived TLC (CT-TLC) was 709 mL lower compared to plethysmography TLC (p-TLC) with a 12.1% deviation from the reference standard, p-TLC. This discrepancy (ΔTLC) appeared slightly larger in obstructive patients (obstructive: 781 mL, non-obstructive: 609 mL), whereas percent deviation was slightly smaller (obstructive: 11.4%, non-obstructive: 13.5%). CT-based RV analyses primarily based on COPD patients measured 603 mL higher than plethysmography (p-RV) with 17.8% deviation from p-RV. Studies utilizing spirometry-gating for CT acquisition reported good agreement between modalities (ΔTLC: 70-280 mL), and one study demonstrated noticeable improvements compared to conventional breath-hold instructions in an otherwise identical study setting.</p><p><strong>Conclusion: </strong>CT quantifications routinely underestimate TLC and overestimate RV in comparison to plethysmography. Spirometry gating reduces the level of disagreement and can be of assistance when patients are already undergoing CT. However, further studies are needed to confirm these results.</p>","PeriodicalId":11872,"journal":{"name":"European Clinical Respiratory Journal","volume":null,"pages":null},"PeriodicalIF":1.8000,"publicationDate":"2024-07-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11288198/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Clinical Respiratory Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/20018525.2024.2381898","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"RESPIRATORY SYSTEM","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Whole-body plethysmography is the preferred method for measuring the static lung volumes: total lung capacity (TLC), functional residual capacity (FRC) and residual volume (RV), as it also incorporates trapped gas - a common finding in chronic obstructive pulmonary disease (COPD). Quantitative computed tomography (CT) is a promising alternative to plethysmography, which can be challenging to perform for patients with severely impaired lung function. The present systematic review explores the agreement between lung volumes measured by plethysmography and CT, as well as the attempts being made to optimize alignment between these two methods.

Methods: A literature search was performed on the PubMed database using the block search strategy. Articles were included if they provided both CT based and plethysmography based TLC. Risk of bias was evaluated using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) checklist.

Results: 22 articles were included. On average, CT-derived TLC (CT-TLC) was 709 mL lower compared to plethysmography TLC (p-TLC) with a 12.1% deviation from the reference standard, p-TLC. This discrepancy (ΔTLC) appeared slightly larger in obstructive patients (obstructive: 781 mL, non-obstructive: 609 mL), whereas percent deviation was slightly smaller (obstructive: 11.4%, non-obstructive: 13.5%). CT-based RV analyses primarily based on COPD patients measured 603 mL higher than plethysmography (p-RV) with 17.8% deviation from p-RV. Studies utilizing spirometry-gating for CT acquisition reported good agreement between modalities (ΔTLC: 70-280 mL), and one study demonstrated noticeable improvements compared to conventional breath-hold instructions in an otherwise identical study setting.

Conclusion: CT quantifications routinely underestimate TLC and overestimate RV in comparison to plethysmography. Spirometry gating reduces the level of disagreement and can be of assistance when patients are already undergoing CT. However, further studies are needed to confirm these results.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
计算机断层扫描和全身胸透测量肺容量的比较--系统综述。
简介全身胸透是测量静态肺容量:总肺活量(TLC)、功能性残余肺活量(FRC)和残余容积(RV)的首选方法,因为它还包括慢性阻塞性肺病(COPD)中常见的滞留气体。定量计算机断层扫描(CT)是一种很有前景的胸透替代方法,但对于肺功能严重受损的患者来说,进行胸透具有挑战性。本系统性综述探讨了胸透和 CT 测量的肺容积之间的一致性,以及为优化这两种方法之间的一致性所做的尝试:采用分块检索策略在 PubMed 数据库中进行文献检索。同时提供基于 CT 和基于胸压测量的 TLC 的文章均被纳入。采用诊断准确性研究质量评估2(QUADAS-2)核对表对偏倚风险进行评估。与胸透 TLC(p-TLC)相比,CT 导出的 TLC(CT-TLC)平均低 709 mL,与参考标准 p-TLC 的偏差为 12.1%。这一差异(ΔTLC)在阻塞性患者中稍大(阻塞性:781 mL,非阻塞性:609 mL),而偏差百分比稍小(阻塞性:11.4%,非阻塞性:13.5%)。基于 CT 的 RV 分析主要基于 COPD 患者,测量结果比胸膜透射法(p-RV)高 603 毫升,与 p-RV 的偏差为 17.8%。在 CT 采集过程中使用肺活量门控技术的研究报告显示,不同模式之间的一致性很好(ΔTLC:70-280 mL),其中一项研究显示,在相同的研究环境下,与传统的屏气指导相比,CT 定量有明显改善:结论:与血气分析相比,CT 定量通常会低估 TLC 和高估 RV。肺活量门控可减少分歧程度,并可在患者已接受 CT 检查时提供帮助。不过,还需要进一步的研究来证实这些结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.80
自引率
0.00%
发文量
15
审稿时长
16 weeks
期刊最新文献
Factors behind favorable long-term lung cancer survival in Norway compared to Denmark: a retrospective cohort study. Socioeconomic status and emergency department visits in adults with a history of severe childhood asthma: a register-based study. Comorbid allergy and rhinitis and patient-related outcomes in asthma and COPD: a cross-sectional study. Lung function measurements in the Greenlandic Inuit population: results from the Greenlandic health survey 2017-2019. Asthma severity: the patient's point of view.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1