An ultra-fast green ultra-high-performance liquid chromatography-tandem mass spectrometry method for estimating the in vitro metabolic stability of zotizalkib in human liver microsomes
Mohamed W. Attwa, Ali S. Abdelhameed, Adnan A. Kadi
{"title":"An ultra-fast green ultra-high-performance liquid chromatography-tandem mass spectrometry method for estimating the in vitro metabolic stability of zotizalkib in human liver microsomes","authors":"Mohamed W. Attwa, Ali S. Abdelhameed, Adnan A. Kadi","doi":"10.1002/jssc.202400393","DOIUrl":null,"url":null,"abstract":"<p>Zotizalkib (ZTK, TPX-0131) is a fourth-generation highly effective inhibitor of wild-type anaplastic lymphoma kinase (ALK) and ALK-resistant mutations that can penetrate the central nervous system. It exhibited greater potency compared to all five officially approved ALK inhibitors. The aim of this study was to develop a rapid, accurate, eco-friendly, and highly sensitive ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method for measuring the concentration of ZTK in human liver microsomes (HLMs). The validation aspects of the current UHPLC-MS/MS methodology in the HLMs were conducted in accordance with the bioanalytical method validation standards specified by the US Food and Drug Administration. ZTK and encorafenib were separated using an Agilent C8 column (Eclipse Plus) and an isocratic mobile phase. The calibration curve for the developed ZTK exhibited a linear relationship within the concentration range of 1–3000 ng/mL. The results from the Analytical Green-ness Metric Approach program (0.76) suggested that the created method demonstrated a significant degree of environmental sustainability. The in vitro half-life (t<sub>1/2</sub>) and intrinsic clearance (Cl<sub>int</sub>) of ZTK were determined to be 15.79 min and 51.35 mL/min/kg, respectively that suggests the ZTK exhibits characteristics similar to those of a medication with a high extraction ratio. These approaches are crucial for the progress of novel pharmaceutical development, especially in improving metabolic stability.</p>","PeriodicalId":17098,"journal":{"name":"Journal of separation science","volume":"47 15","pages":""},"PeriodicalIF":2.8000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of separation science","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/jssc.202400393","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Zotizalkib (ZTK, TPX-0131) is a fourth-generation highly effective inhibitor of wild-type anaplastic lymphoma kinase (ALK) and ALK-resistant mutations that can penetrate the central nervous system. It exhibited greater potency compared to all five officially approved ALK inhibitors. The aim of this study was to develop a rapid, accurate, eco-friendly, and highly sensitive ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method for measuring the concentration of ZTK in human liver microsomes (HLMs). The validation aspects of the current UHPLC-MS/MS methodology in the HLMs were conducted in accordance with the bioanalytical method validation standards specified by the US Food and Drug Administration. ZTK and encorafenib were separated using an Agilent C8 column (Eclipse Plus) and an isocratic mobile phase. The calibration curve for the developed ZTK exhibited a linear relationship within the concentration range of 1–3000 ng/mL. The results from the Analytical Green-ness Metric Approach program (0.76) suggested that the created method demonstrated a significant degree of environmental sustainability. The in vitro half-life (t1/2) and intrinsic clearance (Clint) of ZTK were determined to be 15.79 min and 51.35 mL/min/kg, respectively that suggests the ZTK exhibits characteristics similar to those of a medication with a high extraction ratio. These approaches are crucial for the progress of novel pharmaceutical development, especially in improving metabolic stability.
期刊介绍:
The Journal of Separation Science (JSS) is the most comprehensive source in separation science, since it covers all areas of chromatographic and electrophoretic separation methods in theory and practice, both in the analytical and in the preparative mode, solid phase extraction, sample preparation, and related techniques. Manuscripts on methodological or instrumental developments, including detection aspects, in particular mass spectrometry, as well as on innovative applications will also be published. Manuscripts on hyphenation, automation, and miniaturization are particularly welcome. Pre- and post-separation facets of a total analysis may be covered as well as the underlying logic of the development or application of a method.