Jéssica Cordeiro Queiroz de Souza, Paula Rocha Chellini, Marcus Vinícius Nora de Souza, Marcone Augusto Leal de Oliveira
{"title":"Primaquine Analysis in Pharmaceutical Formulation Using Multiple and Short-End Injections by Capillary Zone Electrophoresis-Ultraviolet Detection","authors":"Jéssica Cordeiro Queiroz de Souza, Paula Rocha Chellini, Marcus Vinícius Nora de Souza, Marcone Augusto Leal de Oliveira","doi":"10.1002/jssc.70026","DOIUrl":null,"url":null,"abstract":"<div>\n \n <p>Novel methods were proposed for determining primaquine (PQN) in tablets by multiple-injection capillary zone electrophoresis (MI-CZE) and by short-end injection CZE (SEI-CZE), both with ultraviolet detection. The background electrolyte (BGE), consisting of 20 mmol/L of tris (hydroxymethyl) aminomethane and 30 mmol/L of hydrochloric acid at pH 2.0, was selected considering a comprehensive study involving the effective mobility versus pH curves of the analytes and BGE components. Experimental designs were applied in methods developments, showing the chemometric tool's applicability in achieving suitable electrophoretic conditions. A baseline resolution in the separation of adjacent peak pairs was obtained by injecting a spacer electrolyte for 18 s, with a voltage of + 15 kV, and the sample can be injected six consecutive times in a single run in less than 3 min, in the MI-CZE method. For the SEI-CZE method, the migration time of PQN was 0.6 min, and the method was applied to a demonstrative forced degradation study. Some validation parameters were evaluated for both methods, and all results were satisfactory, indicating that they can be implemented as PQN determination methods in routine quality control analyses.</p>\n </div>","PeriodicalId":17098,"journal":{"name":"Journal of separation science","volume":"47 22","pages":""},"PeriodicalIF":2.8000,"publicationDate":"2024-11-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of separation science","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/jssc.70026","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Novel methods were proposed for determining primaquine (PQN) in tablets by multiple-injection capillary zone electrophoresis (MI-CZE) and by short-end injection CZE (SEI-CZE), both with ultraviolet detection. The background electrolyte (BGE), consisting of 20 mmol/L of tris (hydroxymethyl) aminomethane and 30 mmol/L of hydrochloric acid at pH 2.0, was selected considering a comprehensive study involving the effective mobility versus pH curves of the analytes and BGE components. Experimental designs were applied in methods developments, showing the chemometric tool's applicability in achieving suitable electrophoretic conditions. A baseline resolution in the separation of adjacent peak pairs was obtained by injecting a spacer electrolyte for 18 s, with a voltage of + 15 kV, and the sample can be injected six consecutive times in a single run in less than 3 min, in the MI-CZE method. For the SEI-CZE method, the migration time of PQN was 0.6 min, and the method was applied to a demonstrative forced degradation study. Some validation parameters were evaluated for both methods, and all results were satisfactory, indicating that they can be implemented as PQN determination methods in routine quality control analyses.
期刊介绍:
The Journal of Separation Science (JSS) is the most comprehensive source in separation science, since it covers all areas of chromatographic and electrophoretic separation methods in theory and practice, both in the analytical and in the preparative mode, solid phase extraction, sample preparation, and related techniques. Manuscripts on methodological or instrumental developments, including detection aspects, in particular mass spectrometry, as well as on innovative applications will also be published. Manuscripts on hyphenation, automation, and miniaturization are particularly welcome. Pre- and post-separation facets of a total analysis may be covered as well as the underlying logic of the development or application of a method.