Ultra-Sensitive and Selective Surface Plasmon Resonance using Ag Metal, Carbon Nanotube, and Selenium Based Biosensors for the Detection of Ascorbic Acid

IF 1.8 4区 材料科学 Q3 MATERIALS SCIENCE, MULTIDISCIPLINARY ECS Journal of Solid State Science and Technology Pub Date : 2024-08-06 DOI:10.1149/2162-8777/ad6806
Saravanan Pandiaraj, Adham Aleid, Khalid Alhussaini and Abdullah N. Alodhayb
{"title":"Ultra-Sensitive and Selective Surface Plasmon Resonance using Ag Metal, Carbon Nanotube, and Selenium Based Biosensors for the Detection of Ascorbic Acid","authors":"Saravanan Pandiaraj, Adham Aleid, Khalid Alhussaini and Abdullah N. Alodhayb","doi":"10.1149/2162-8777/ad6806","DOIUrl":null,"url":null,"abstract":"In this work, we present a novel surface plasmon resonance (SPR) sensor for ascorbic acid detection based on a borosilicate crown (BK7) prism coated with a multilayer structure made of ferric oxide (Fe2O3), silver (Ag), and carbon nanotube (CNT). The SPR sensor improves sensitivity and selectivity for ascorbic acid detection by taking advantage of the special optical characteristics of the multilayer construction. The CNT layer offers increased surface area and biocompatibility, and the Ag layer acts as a plasmonic material to promote surface plasmons. The performance of the sensor is improved by the addition of selenium (Se) and Fe2O3 layers, which provide further capabilities like photoconductivity and magnetic manipulation, respectively. Numerical analysis at the operating wavelength of 633 nm is conducted using the transfer matrix approach. For the proposed SPR sensor at room temperature, the performance characteristics, including sensitivity (274.37 degree (°)/RIU), figure of merit (40.60 RIU−1), and detection accuracy (0.189°−1), are computed. The proposed SPR sensor could be very useful in to detect ascorbic acid in the visible range.","PeriodicalId":11496,"journal":{"name":"ECS Journal of Solid State Science and Technology","volume":"27 1","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2024-08-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ECS Journal of Solid State Science and Technology","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.1149/2162-8777/ad6806","RegionNum":4,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MATERIALS SCIENCE, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

In this work, we present a novel surface plasmon resonance (SPR) sensor for ascorbic acid detection based on a borosilicate crown (BK7) prism coated with a multilayer structure made of ferric oxide (Fe2O3), silver (Ag), and carbon nanotube (CNT). The SPR sensor improves sensitivity and selectivity for ascorbic acid detection by taking advantage of the special optical characteristics of the multilayer construction. The CNT layer offers increased surface area and biocompatibility, and the Ag layer acts as a plasmonic material to promote surface plasmons. The performance of the sensor is improved by the addition of selenium (Se) and Fe2O3 layers, which provide further capabilities like photoconductivity and magnetic manipulation, respectively. Numerical analysis at the operating wavelength of 633 nm is conducted using the transfer matrix approach. For the proposed SPR sensor at room temperature, the performance characteristics, including sensitivity (274.37 degree (°)/RIU), figure of merit (40.60 RIU−1), and detection accuracy (0.189°−1), are computed. The proposed SPR sensor could be very useful in to detect ascorbic acid in the visible range.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用基于银金属、碳纳米管和硒的超灵敏和选择性表面等离子体共振生物传感器检测抗坏血酸
在这项工作中,我们提出了一种新型的表面等离子体共振(SPR)传感器,用于检测抗坏血酸,该传感器基于硼硅冠(BK7)棱镜,棱镜上镀有由氧化铁(Fe2O3)、银(Ag)和碳纳米管(CNT)组成的多层结构。SPR 传感器利用多层结构的特殊光学特性,提高了抗坏血酸检测的灵敏度和选择性。碳纳米管层增加了表面积和生物相容性,而银层则是一种促进表面等离子体的等离子体材料。通过添加硒(Se)层和 Fe2O3 层,传感器的性能得到了进一步提高,这两层分别提供了光电导和磁操控等功能。利用传递矩阵方法对工作波长为 633 纳米的传感器进行了数值分析。计算出了拟议的 SPR 传感器在室温下的性能特征,包括灵敏度(274.37 度 (°)/RIU)、优点系数(40.60 RIU-1)和检测精度(0.189°-1)。所提出的 SPR 传感器可用于检测可见光范围内的抗坏血酸。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
ECS Journal of Solid State Science and Technology
ECS Journal of Solid State Science and Technology MATERIALS SCIENCE, MULTIDISCIPLINARY-PHYSICS, APPLIED
CiteScore
4.50
自引率
13.60%
发文量
455
期刊介绍: The ECS Journal of Solid State Science and Technology (JSS) was launched in 2012, and publishes outstanding research covering fundamental and applied areas of solid state science and technology, including experimental and theoretical aspects of the chemistry and physics of materials and devices. JSS has five topical interest areas: carbon nanostructures and devices dielectric science and materials electronic materials and processing electronic and photonic devices and systems luminescence and display materials, devices and processing.
期刊最新文献
Au-free V/Al/Pt Contacts on n-Al0.85Ga0.15N:Si Surfaces of Far-UVC LEDs Structural Characteristics and Dielectric Properties of Deposited Silver Nanoparticles with Polypyrrole on PET Films for Dielectric Devices Modification of Structural, Optical, and Electrical Properties of PVA/PVP Blend Filled by Nanostructured Titanium Dioxide for Optoelectronic Applications Low Contact Resistance via Quantum Well Structure in Amorphous InMoO Thin Film Transistors Comparative Analysis of 50 MeV Li3+ and 100 MeV O7+ Ion Beam Induced Electrical Modifications in Silicon Photodetectors
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1