Qinqin Cheng, Ruifeng Zhao, Xiaowa Wang, Xufei Wang
{"title":"Collimation principles of a hollow X-ray microbeam for high-contrast cytoplasm irradiation.","authors":"Qinqin Cheng, Ruifeng Zhao, Xiaowa Wang, Xufei Wang","doi":"10.1093/jrr/rrae046","DOIUrl":null,"url":null,"abstract":"<p><p>A Monte Carlo simulation was used to assess the performance of a collimated hollow X-ray microbeam for subcellular cytoplasm irradiation. A high-Z coaxial collimation structure with an inner core for nucleus shielding was investigated. Two key performances, the extraction efficiency (cytoplasm dose per unit incident fluence) and the dose contrast (cytoplasm-to-nucleus dose ratio), were evaluated regarding the influences of the material, geometry and physical arrangements of the collimator, target dish and incident beam source. Simulation results demonstrate that a gold coaxial structure with a practical collimation geometry of a 1-mm length, 10-μm inner diameter and 200-μm outer diameter, with the top exit closely attached (with a minimized air gap) to the bottom of a cell dish with a 3-μm thick Mylar film is recommended for cytoplasm irradiation of adherent mammalian cells. For a synchrotron source in the energy range < 10 keV, a dose contrast of approximately 100 can be achieved. For a bremsstrahlung source <30-kV tube voltage, a dose contrast of approximately 50-100 can still be achieved. General principles are summarized with further explanations of the performance of the hollow X-ray microbeam.</p>","PeriodicalId":16922,"journal":{"name":"Journal of Radiation Research","volume":" ","pages":"591-602"},"PeriodicalIF":1.9000,"publicationDate":"2024-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11420837/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Radiation Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/jrr/rrae046","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
A Monte Carlo simulation was used to assess the performance of a collimated hollow X-ray microbeam for subcellular cytoplasm irradiation. A high-Z coaxial collimation structure with an inner core for nucleus shielding was investigated. Two key performances, the extraction efficiency (cytoplasm dose per unit incident fluence) and the dose contrast (cytoplasm-to-nucleus dose ratio), were evaluated regarding the influences of the material, geometry and physical arrangements of the collimator, target dish and incident beam source. Simulation results demonstrate that a gold coaxial structure with a practical collimation geometry of a 1-mm length, 10-μm inner diameter and 200-μm outer diameter, with the top exit closely attached (with a minimized air gap) to the bottom of a cell dish with a 3-μm thick Mylar film is recommended for cytoplasm irradiation of adherent mammalian cells. For a synchrotron source in the energy range < 10 keV, a dose contrast of approximately 100 can be achieved. For a bremsstrahlung source <30-kV tube voltage, a dose contrast of approximately 50-100 can still be achieved. General principles are summarized with further explanations of the performance of the hollow X-ray microbeam.
期刊介绍:
The Journal of Radiation Research (JRR) is an official journal of The Japanese Radiation Research Society (JRRS), and the Japanese Society for Radiation Oncology (JASTRO).
Since its launch in 1960 as the official journal of the JRRS, the journal has published scientific articles in radiation science in biology, chemistry, physics, epidemiology, and environmental sciences. JRR broadened its scope to include oncology in 2009, when JASTRO partnered with the JRRS to publish the journal.
Articles considered fall into two broad categories:
Oncology & Medicine - including all aspects of research with patients that impacts on the treatment of cancer using radiation. Papers which cover related radiation therapies, radiation dosimetry, and those describing the basis for treatment methods including techniques, are also welcomed. Clinical case reports are not acceptable.
Radiation Research - basic science studies of radiation effects on livings in the area of physics, chemistry, biology, epidemiology and environmental sciences.
Please be advised that JRR does not accept any papers of pure physics or chemistry.
The journal is bimonthly, and is edited and published by the JRR Editorial Committee.