Apparent local anesthetic systemic toxicity following activation of an epidural catheter for cesarean delivery: diagnosis and management of an uncommon obstetric anesthesia complication.

Q3 Medicine Baylor University Medical Center Proceedings Pub Date : 2024-05-28 eCollection Date: 2024-01-01 DOI:10.1080/08998280.2024.2357522
Youstina Soliman, Angelica A Hatfield, Russell K McAllister, Michael R Fettiplace, Michael P Hofkamp
{"title":"Apparent local anesthetic systemic toxicity following activation of an epidural catheter for cesarean delivery: diagnosis and management of an uncommon obstetric anesthesia complication.","authors":"Youstina Soliman, Angelica A Hatfield, Russell K McAllister, Michael R Fettiplace, Michael P Hofkamp","doi":"10.1080/08998280.2024.2357522","DOIUrl":null,"url":null,"abstract":"<p><p>We present a 25-year-old, gravida 2, para 1 woman who developed apparent local anesthetic systemic toxicity (LAST) following activation of an epidural catheter for an urgent cesarean delivery. The patient had a height of 150 cm, weight of 92 kg, body mass index of 41 kg/m<sup>2</sup>, and calculated ideal body weight of 40 kg. A combined spinal epidural anesthetic was placed and the spinal component did not provide anesthesia to clamping of the abdomen. Subsequently, 300 mg of lidocaine was administered through the epidural catheter in three 5 mL doses over 8 minutes and surgery commenced. Approximately 30 minutes following the final 5 mL dose of epidural lidocaine, the patient had progressive loss of consciousness and was difficult to arouse. A presumptive diagnosis of LAST was made, and 60 mL of 20% intravenous lipid emulsion was administered. The patient's mental status improved to baseline within 5 minutes of lipid emulsion administration, and she made a complete recovery. Anesthesiologists should consider using ideal body weight when calculating the maximum dosage of local anesthetics, and LAST should be part of the differential diagnosis when patients have altered mental status in the setting of local anesthetic administration that exceeds recommended dosages.</p>","PeriodicalId":8828,"journal":{"name":"Baylor University Medical Center Proceedings","volume":"37 5","pages":"874-876"},"PeriodicalIF":0.0000,"publicationDate":"2024-05-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11332648/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Baylor University Medical Center Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/08998280.2024.2357522","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

We present a 25-year-old, gravida 2, para 1 woman who developed apparent local anesthetic systemic toxicity (LAST) following activation of an epidural catheter for an urgent cesarean delivery. The patient had a height of 150 cm, weight of 92 kg, body mass index of 41 kg/m2, and calculated ideal body weight of 40 kg. A combined spinal epidural anesthetic was placed and the spinal component did not provide anesthesia to clamping of the abdomen. Subsequently, 300 mg of lidocaine was administered through the epidural catheter in three 5 mL doses over 8 minutes and surgery commenced. Approximately 30 minutes following the final 5 mL dose of epidural lidocaine, the patient had progressive loss of consciousness and was difficult to arouse. A presumptive diagnosis of LAST was made, and 60 mL of 20% intravenous lipid emulsion was administered. The patient's mental status improved to baseline within 5 minutes of lipid emulsion administration, and she made a complete recovery. Anesthesiologists should consider using ideal body weight when calculating the maximum dosage of local anesthetics, and LAST should be part of the differential diagnosis when patients have altered mental status in the setting of local anesthetic administration that exceeds recommended dosages.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
剖宫产硬膜外导管激活后明显的局麻药全身中毒:一种不常见的产科麻醉并发症的诊断和处理。
我们为您介绍一位 25 岁、孕期 2、产次 1 的产妇,她在紧急剖宫产时使用硬膜外导管后出现了明显的局麻药全身毒性(LAST)。患者身高 150 厘米,体重 92 千克,体重指数为 41 千克/平方米,理想体重为 40 千克。患者接受了脊髓硬膜外联合麻醉,但脊髓部分没有为夹紧腹部提供麻醉。随后,通过硬膜外导管在 8 分钟内分三次注射了 5 毫升 300 毫克利多卡因,手术开始。最后一次硬膜外注射 5 毫升利多卡因约 30 分钟后,患者逐渐失去知觉,难以唤醒。推测诊断为 LAST,于是静脉注射了 60 毫升 20% 的脂质乳剂。注射脂质乳剂后 5 分钟内,患者的精神状态改善至基线,并完全康复。麻醉医师在计算局麻药的最大剂量时应考虑使用理想体重,如果患者在使用超过推荐剂量的局麻药时出现精神状态改变,则应将 LAST 作为鉴别诊断的一部分。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.30
自引率
0.00%
发文量
245
期刊最新文献
The importance of screening and surveillance: Barrett's esophagus and esophageal cancer. A brief descriptive analysis of a pilot study of peer support training and supervision for Texas firefighters. Contrast-associated acute kidney injury: How can we do better? "In a word, partnership"-lessons from a student-led health fair. A review of professionalism in surgery.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1