{"title":"Uni-directional ATES in high groundwater flow aquifers","authors":"Valerio Silvestri , Giovanni Crosta , Alberto Previati , Paolo Frattini , Martin Bloemendal","doi":"10.1016/j.geothermics.2024.103152","DOIUrl":null,"url":null,"abstract":"<div><p>Aquifer thermal energy storage (ATES) is attained by storing thermal energy in aquifers, using the groundwater as a carrier for the heat. Hence, in ATES systems, the background groundwater flow velocity may affect the efficiency if a significant amount of stored heat is moved away from the storage well by advection. This paper presents an alternative solution to the typical “pump and dump” open-loop shallow geothermal system configuration using the ATES concept with a reversed extraction-injection well scheme. This particular placement is able to increase the energy efficiency of a conventional open-loop system while reducing the thermal impact downstream the system.</p><p>The uni-directional ATES pumping scheme compensates the heat transport by groundwater flow extracting the groundwater from the downstream well and re-injecting back in the upstream well. This research presents a numerical feasibility study and sensitivity analysis of the effects of the well spacing, pumping scheme and groundwater flow velocity on the efficiency of a uni-directional ATES. Optimal combinations are suggested to ensure the maximum re-capture by the downstream well of the heat injected in the upstream well in the previous season and subject to thermal transport by advection, with a maximum heat recovery between 55 and 75 % depending on the conditions. The results of the modelling analysis showed that the optimal inter-well distance depends on the groundwater flow velocity and the total annual storage volume. This paper also demonstrates the mitigation effect of the thermal perturbation downstream of a uni-directional ATES compared to a conventional open-loop scheme.</p></div>","PeriodicalId":55095,"journal":{"name":"Geothermics","volume":"125 ","pages":"Article 103152"},"PeriodicalIF":3.5000,"publicationDate":"2024-09-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0375650524002384/pdfft?md5=e73a43c1f8c2a128b35c1a153b9a8497&pid=1-s2.0-S0375650524002384-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Geothermics","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0375650524002384","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0
Abstract
Aquifer thermal energy storage (ATES) is attained by storing thermal energy in aquifers, using the groundwater as a carrier for the heat. Hence, in ATES systems, the background groundwater flow velocity may affect the efficiency if a significant amount of stored heat is moved away from the storage well by advection. This paper presents an alternative solution to the typical “pump and dump” open-loop shallow geothermal system configuration using the ATES concept with a reversed extraction-injection well scheme. This particular placement is able to increase the energy efficiency of a conventional open-loop system while reducing the thermal impact downstream the system.
The uni-directional ATES pumping scheme compensates the heat transport by groundwater flow extracting the groundwater from the downstream well and re-injecting back in the upstream well. This research presents a numerical feasibility study and sensitivity analysis of the effects of the well spacing, pumping scheme and groundwater flow velocity on the efficiency of a uni-directional ATES. Optimal combinations are suggested to ensure the maximum re-capture by the downstream well of the heat injected in the upstream well in the previous season and subject to thermal transport by advection, with a maximum heat recovery between 55 and 75 % depending on the conditions. The results of the modelling analysis showed that the optimal inter-well distance depends on the groundwater flow velocity and the total annual storage volume. This paper also demonstrates the mitigation effect of the thermal perturbation downstream of a uni-directional ATES compared to a conventional open-loop scheme.
期刊介绍:
Geothermics is an international journal devoted to the research and development of geothermal energy. The International Board of Editors of Geothermics, which comprises specialists in the various aspects of geothermal resources, exploration and development, guarantees the balanced, comprehensive view of scientific and technological developments in this promising energy field.
It promulgates the state of the art and science of geothermal energy, its exploration and exploitation through a regular exchange of information from all parts of the world. The journal publishes articles dealing with the theory, exploration techniques and all aspects of the utilization of geothermal resources. Geothermics serves as the scientific house, or exchange medium, through which the growing community of geothermal specialists can provide and receive information.