Effect of ambient air and ground temperatures on heat transfer in underground power cable system buried in newly developed cable bedding material

IF 3.5 2区 工程技术 Q3 ENERGY & FUELS Geothermics Pub Date : 2024-09-09 DOI:10.1016/j.geothermics.2024.103151
{"title":"Effect of ambient air and ground temperatures on heat transfer in underground power cable system buried in newly developed cable bedding material","authors":"","doi":"10.1016/j.geothermics.2024.103151","DOIUrl":null,"url":null,"abstract":"<div><p>Underground power cable systems (UPCSs) are generally buried close to the ground surface, exposing them to significant influences from ambient air and ground temperatures, which can affect heat dissipation and thermal efficiency. This study compares the heat transfer performance of UPCS with different cable bedding materials at critical current carrying capacity, considering the effects of ambient air and ground temperatures on system performance. The findings indicate that current carrying capacity decreases with higher ground temperatures, and that the critical ampacity leading to maximum cable temperature in UPCS is significantly influenced by actual ambient air and ground temperatures, rather than standard reference values like 20 °C. The newly developed cable bedding material, prepacked aggregate concrete (PAC), to enhance heat dissipation efficiency and prevent cable overheating is also proposed. Experimentally, PAC, with a higher thermal conductivity of 2.094 W/(m·K) versus 1.365 W/(m·K) for sand, lowers the maximum cable temperature to 70.6 °C, compared to 77.6 °C for sand under critical conditions. Moreover, the analytical solutions for ground temperature distribution models as boundary conditions are also highlighted, in which steady-state ground temperature analysis at the relevant depth may impact the accuracy of cable temperature predictions related to UPCS operation for both the system itself and the surrounding earth materials.</p></div>","PeriodicalId":55095,"journal":{"name":"Geothermics","volume":null,"pages":null},"PeriodicalIF":3.5000,"publicationDate":"2024-09-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0375650524002372/pdfft?md5=016e860cd05370bef667af45f898f4f3&pid=1-s2.0-S0375650524002372-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Geothermics","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0375650524002372","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

Abstract

Underground power cable systems (UPCSs) are generally buried close to the ground surface, exposing them to significant influences from ambient air and ground temperatures, which can affect heat dissipation and thermal efficiency. This study compares the heat transfer performance of UPCS with different cable bedding materials at critical current carrying capacity, considering the effects of ambient air and ground temperatures on system performance. The findings indicate that current carrying capacity decreases with higher ground temperatures, and that the critical ampacity leading to maximum cable temperature in UPCS is significantly influenced by actual ambient air and ground temperatures, rather than standard reference values like 20 °C. The newly developed cable bedding material, prepacked aggregate concrete (PAC), to enhance heat dissipation efficiency and prevent cable overheating is also proposed. Experimentally, PAC, with a higher thermal conductivity of 2.094 W/(m·K) versus 1.365 W/(m·K) for sand, lowers the maximum cable temperature to 70.6 °C, compared to 77.6 °C for sand under critical conditions. Moreover, the analytical solutions for ground temperature distribution models as boundary conditions are also highlighted, in which steady-state ground temperature analysis at the relevant depth may impact the accuracy of cable temperature predictions related to UPCS operation for both the system itself and the surrounding earth materials.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
环境空气和地面温度对埋设在新开发电缆垫层材料中的地下电力电缆系统传热的影响
地下电力电缆系统(UPCS)通常埋设在靠近地表的地方,因此会受到周围空气和地面温度的严重影响,从而影响散热和热效率。考虑到环境空气和地面温度对系统性能的影响,本研究比较了不同电缆垫层材料的 UPCS 在临界电流承载能力下的传热性能。研究结果表明,电流承载能力随着地面温度的升高而降低,导致 UPCS 中电缆温度达到最高值的临界电流承载能力受到实际环境空气和地面温度的显著影响,而不是像 20 °C 这样的标准参考值。此外,还提出了新开发的电缆垫层材料--预包装骨料混凝土(PAC),以提高散热效率,防止电缆过热。实验结果表明,PAC 的导热系数为 2.094 W/(m-K),而沙子的导热系数为 1.365 W/(m-K),在临界条件下,PAC 可将电缆的最高温度降至 70.6 °C,而沙子的最高温度为 77.6 °C。此外,还强调了作为边界条件的地温分布模型的分析解决方案,其中相关深度的稳态地温分析可能会影响与 UPCS 运行有关的电缆温度预测的准确性,包括系统本身和周围的土层材料。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Geothermics
Geothermics 工程技术-地球科学综合
CiteScore
7.70
自引率
15.40%
发文量
237
审稿时长
4.5 months
期刊介绍: Geothermics is an international journal devoted to the research and development of geothermal energy. The International Board of Editors of Geothermics, which comprises specialists in the various aspects of geothermal resources, exploration and development, guarantees the balanced, comprehensive view of scientific and technological developments in this promising energy field. It promulgates the state of the art and science of geothermal energy, its exploration and exploitation through a regular exchange of information from all parts of the world. The journal publishes articles dealing with the theory, exploration techniques and all aspects of the utilization of geothermal resources. Geothermics serves as the scientific house, or exchange medium, through which the growing community of geothermal specialists can provide and receive information.
期刊最新文献
Numerical investigation of the geometric parameters effect of helical blades installed on horizontal geo heat exchanger A segmented analytical solution heat transfer model of U-tube ground heat exchanger based on finite solid cylindrical heat source method Geothermal distribution and evolution of fault-controlled Linyi geothermal system: Constrained from hydrogeochemical composition and numerical simulation Structural controls on hydrothermal fluid flow in a carbonate geothermal reservoir: Insights from giant carbonate veins in western Germany Experiences as heuristics for geothermal public perception: Testing the correlation between thermal waters recreation and geothermal energy perception
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1