{"title":"Accuracy of deep learning in the differential diagnosis of coronary artery stenosis: a systematic review and meta-analysis","authors":"Li Tu, Ying Deng, Yun Chen, Yi Luo","doi":"10.1186/s12880-024-01403-4","DOIUrl":null,"url":null,"abstract":"In recent years, as deep learning has received widespread attention in the field of heart disease, some studies have explored the potential of deep learning based on coronary angiography (CAG) or coronary CT angiography (CCTA) images in detecting the extent of coronary artery stenosis. However, there is still a lack of a systematic understanding of its diagnostic accuracy, impeding the advancement of intelligent diagnosis of coronary artery stenosis. Therefore, we conducted this study to review the accuracy of image-based deep learning in detecting coronary artery stenosis. We retrieved PubMed, Cochrane, Embase, and Web of Science until April 11, 2023. The risk of bias in the included studies was appraised using the QUADAS-2 tool. We extracted the accuracy of deep learning in the test set and performed subgroup analyses by binary and multiclass classification scenarios. We performed a subgroup analysis based on different degrees of stenosis and applied a double arcsine transformation to process the data. The analysis was done by using R. Our systematic review finally included 18 studies, involving 3568 patients and 13,362 images. In the included studies, deep learning models were constructed based on CAG and CCTA. In binary classification tasks, the accuracy for detecting > 25%, > 50% and > 70% degrees of stenosis at the vessel level were 0.81 (95% CI: 0.71–0.85), 0.73 (95% CI: 0.58–0.88) and 0.61 (95% CI: 0.56–0.65), respectively. In multiclass classification tasks, the accuracy for detecting 0–25%, 25–50%, 50–70%, and 70–100% degrees of stenosis at the vessel level were 0.78 (95% CI: 0.73–0.84), 0.86 (95% CI: 0.78–0.93), 0.83 (95% CI: 0.70–0.97), and 0.70 (95% CI: 0.42–0.98), respectively. Our study shows that deep learning models based on CAG and CCTA appear to be relatively accurate in diagnosing different degrees of coronary artery stenosis. However, for various degrees of stenosis, their accuracy still needs to be further improved.","PeriodicalId":9020,"journal":{"name":"BMC Medical Imaging","volume":null,"pages":null},"PeriodicalIF":2.9000,"publicationDate":"2024-09-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Medical Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12880-024-01403-4","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
In recent years, as deep learning has received widespread attention in the field of heart disease, some studies have explored the potential of deep learning based on coronary angiography (CAG) or coronary CT angiography (CCTA) images in detecting the extent of coronary artery stenosis. However, there is still a lack of a systematic understanding of its diagnostic accuracy, impeding the advancement of intelligent diagnosis of coronary artery stenosis. Therefore, we conducted this study to review the accuracy of image-based deep learning in detecting coronary artery stenosis. We retrieved PubMed, Cochrane, Embase, and Web of Science until April 11, 2023. The risk of bias in the included studies was appraised using the QUADAS-2 tool. We extracted the accuracy of deep learning in the test set and performed subgroup analyses by binary and multiclass classification scenarios. We performed a subgroup analysis based on different degrees of stenosis and applied a double arcsine transformation to process the data. The analysis was done by using R. Our systematic review finally included 18 studies, involving 3568 patients and 13,362 images. In the included studies, deep learning models were constructed based on CAG and CCTA. In binary classification tasks, the accuracy for detecting > 25%, > 50% and > 70% degrees of stenosis at the vessel level were 0.81 (95% CI: 0.71–0.85), 0.73 (95% CI: 0.58–0.88) and 0.61 (95% CI: 0.56–0.65), respectively. In multiclass classification tasks, the accuracy for detecting 0–25%, 25–50%, 50–70%, and 70–100% degrees of stenosis at the vessel level were 0.78 (95% CI: 0.73–0.84), 0.86 (95% CI: 0.78–0.93), 0.83 (95% CI: 0.70–0.97), and 0.70 (95% CI: 0.42–0.98), respectively. Our study shows that deep learning models based on CAG and CCTA appear to be relatively accurate in diagnosing different degrees of coronary artery stenosis. However, for various degrees of stenosis, their accuracy still needs to be further improved.
期刊介绍:
BMC Medical Imaging is an open access journal publishing original peer-reviewed research articles in the development, evaluation, and use of imaging techniques and image processing tools to diagnose and manage disease.