Dongqing Sun , Maryse A. van ’t Klooster , Elise M. Ringeling , Eline V. Schaft , Peter C. van Rijen , Frans S.S. Leijten , Matteo Demuru , Pierre A.J.T. Robe , Reinier G. Hoff , Maeike Zijlmans , the RESPect database group
{"title":"Pausing propofol during neurosurgery to record intraoperative electrocorticography is feasible;10 years of clinical experience","authors":"Dongqing Sun , Maryse A. van ’t Klooster , Elise M. Ringeling , Eline V. Schaft , Peter C. van Rijen , Frans S.S. Leijten , Matteo Demuru , Pierre A.J.T. Robe , Reinier G. Hoff , Maeike Zijlmans , the RESPect database group","doi":"10.1016/j.clinph.2024.08.014","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><p>Intraoperative electrocorticography (ioECoG) during neurosurgery is influenced by anesthetics. In our center we stop the propofol to enable interpretation of ioECoG. We reported our clinical experience and evaluated awareness and hemodynamic changes during the propofol-free periods (PFP).</p></div><div><h3>Methods</h3><p>We retrospectively included surgeries with paused propofol administration to record ioECoG (period: 2008–2019). Clinical reports were screened for symptoms of awareness. We compared mean arterial blood pressure (MAP; mmHg) and heart rate (HR;bpm) during PFP to baseline (ten minutes preceding PFP). An increase > 15% was defined as clinically relevant. The association between hemodynamic changes and clinical characteristics was analyzed using logistic regression models.</p></div><div><h3>Results</h3><p>Propofol administration was paused 742 times in 352 surgeries (mean PFP duration 9 ± 5 min). No signs of awareness were reported. MAP and HR increased > 15% in 54 and six PFPs. Five PFPs showed both MAP and HR increases. Prolonged PFP was associated with having MAP and HR increase during surgery (OR=1.18, 95%CI [1.12–1.26]).</p></div><div><h3>Conclusions</h3><p>Signs of inadequate sedation depth were rare. MAP and HR increases were related to the length of PFP.</p></div><div><h3>Significance</h3><p>We summarize 10 years of clinical experience with pausing propofol administration during epilepsy surgery to record ioECoG without evidence of awareness.</p></div>","PeriodicalId":10671,"journal":{"name":"Clinical Neurophysiology","volume":"167 ","pages":"Pages 84-91"},"PeriodicalIF":3.7000,"publicationDate":"2024-08-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S1388245724002414/pdfft?md5=906c52adcc1eed29a15d4e5e4fcec57f&pid=1-s2.0-S1388245724002414-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Neurophysiology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1388245724002414","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Objective
Intraoperative electrocorticography (ioECoG) during neurosurgery is influenced by anesthetics. In our center we stop the propofol to enable interpretation of ioECoG. We reported our clinical experience and evaluated awareness and hemodynamic changes during the propofol-free periods (PFP).
Methods
We retrospectively included surgeries with paused propofol administration to record ioECoG (period: 2008–2019). Clinical reports were screened for symptoms of awareness. We compared mean arterial blood pressure (MAP; mmHg) and heart rate (HR;bpm) during PFP to baseline (ten minutes preceding PFP). An increase > 15% was defined as clinically relevant. The association between hemodynamic changes and clinical characteristics was analyzed using logistic regression models.
Results
Propofol administration was paused 742 times in 352 surgeries (mean PFP duration 9 ± 5 min). No signs of awareness were reported. MAP and HR increased > 15% in 54 and six PFPs. Five PFPs showed both MAP and HR increases. Prolonged PFP was associated with having MAP and HR increase during surgery (OR=1.18, 95%CI [1.12–1.26]).
Conclusions
Signs of inadequate sedation depth were rare. MAP and HR increases were related to the length of PFP.
Significance
We summarize 10 years of clinical experience with pausing propofol administration during epilepsy surgery to record ioECoG without evidence of awareness.
期刊介绍:
As of January 1999, The journal Electroencephalography and Clinical Neurophysiology, and its two sections Electromyography and Motor Control and Evoked Potentials have amalgamated to become this journal - Clinical Neurophysiology.
Clinical Neurophysiology is the official journal of the International Federation of Clinical Neurophysiology, the Brazilian Society of Clinical Neurophysiology, the Czech Society of Clinical Neurophysiology, the Italian Clinical Neurophysiology Society and the International Society of Intraoperative Neurophysiology.The journal is dedicated to fostering research and disseminating information on all aspects of both normal and abnormal functioning of the nervous system. The key aim of the publication is to disseminate scholarly reports on the pathophysiology underlying diseases of the central and peripheral nervous system of human patients. Clinical trials that use neurophysiological measures to document change are encouraged, as are manuscripts reporting data on integrated neuroimaging of central nervous function including, but not limited to, functional MRI, MEG, EEG, PET and other neuroimaging modalities.