Integration of Group A Streptococcus Rapid Tests with the Open Fluidic CandyCollect Device

Juan Carlos Sanchez, Ingrid H Robertson, Victoria A.M. Shinakawa, Xiaojing Su, Wan-chen Tu, Timothy R. Robinson, Megan M. Chang, Andrea Blom, Elena Alfaro, Daniel B. Hatchett, Ayokunle O. Olanrewaju, Ellen R. Wald, Gregory P. DeMuri, Erwin Erwin Berthier, Sanitta Thongpang, Ashleigh B Theberge
{"title":"Integration of Group A Streptococcus Rapid Tests with the Open Fluidic CandyCollect Device","authors":"Juan Carlos Sanchez, Ingrid H Robertson, Victoria A.M. Shinakawa, Xiaojing Su, Wan-chen Tu, Timothy R. Robinson, Megan M. Chang, Andrea Blom, Elena Alfaro, Daniel B. Hatchett, Ayokunle O. Olanrewaju, Ellen R. Wald, Gregory P. DeMuri, Erwin Erwin Berthier, Sanitta Thongpang, Ashleigh B Theberge","doi":"10.1101/2024.09.16.24312510","DOIUrl":null,"url":null,"abstract":"The CandyCollect device is a lollipop-inspired open fluidic oral sampling device designed to provide a comfortable user sampling experience. We demonstrate that the CandyCollect device can be coupled with a rapid antigen detection test (RADT) kit designed for Group A Streptococcus (GAS). Through <em>in vitro</em> experiments with pooled saliva spiked with <em>Streptococcus pyogenes</em> we tested various reagents and elution volumes to optimize the RADT readout from CandyCollect device samples. The resulting optimized protocol uses the kit-provided reagents and lateral flow assay (LFA) while replacing the kit′s pharyngeal swab with the CandyCollect device, reducing the elution solution volume, and substituting the tube used for elution to accommodate the CandyCollect device. Positive test results were detected by eye with bacterial concentrations as low as the manufacturer′s ″minimal detection limit″ - 1.5x10<sup>5</sup> CFU/mL. LFA strips were also scanned and quantified with image analysis software to determine the signal-to-baseline ratio (SBR) and categorize positive test results without human bias. We tested our optimized protocol for integrating CandyCollect and RADT using CandyCollect clinical samples from pediatric patients (n=6) who were previously diagnosed with GAS pharyngitis via pharyngeal swabs tested with RADT as part of their clinical care. The LFA results of these CandyCollect devices and interspersed negative controls were determined by independent observers, with positive results obtained in four of the six participants on at least one LFA replicate. Taken together, our results show that CandyCollect devices from children with GAS pharyngitis can be tested using LFA rapid tests.","PeriodicalId":501509,"journal":{"name":"medRxiv - Infectious Diseases","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-09-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"medRxiv - Infectious Diseases","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1101/2024.09.16.24312510","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The CandyCollect device is a lollipop-inspired open fluidic oral sampling device designed to provide a comfortable user sampling experience. We demonstrate that the CandyCollect device can be coupled with a rapid antigen detection test (RADT) kit designed for Group A Streptococcus (GAS). Through in vitro experiments with pooled saliva spiked with Streptococcus pyogenes we tested various reagents and elution volumes to optimize the RADT readout from CandyCollect device samples. The resulting optimized protocol uses the kit-provided reagents and lateral flow assay (LFA) while replacing the kit′s pharyngeal swab with the CandyCollect device, reducing the elution solution volume, and substituting the tube used for elution to accommodate the CandyCollect device. Positive test results were detected by eye with bacterial concentrations as low as the manufacturer′s ″minimal detection limit″ - 1.5x105 CFU/mL. LFA strips were also scanned and quantified with image analysis software to determine the signal-to-baseline ratio (SBR) and categorize positive test results without human bias. We tested our optimized protocol for integrating CandyCollect and RADT using CandyCollect clinical samples from pediatric patients (n=6) who were previously diagnosed with GAS pharyngitis via pharyngeal swabs tested with RADT as part of their clinical care. The LFA results of these CandyCollect devices and interspersed negative controls were determined by independent observers, with positive results obtained in four of the six participants on at least one LFA replicate. Taken together, our results show that CandyCollect devices from children with GAS pharyngitis can be tested using LFA rapid tests.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
将 A 群链球菌快速检测与开放式流体糖果采集装置相结合
CandyCollect 设备是一种受棒棒糖启发设计的开放式流体口腔采样设备,旨在为用户提供舒适的采样体验。我们证明了 CandyCollect 设备可与针对 A 群链球菌 (GAS) 设计的快速抗原检测试剂盒 (RADT) 结合使用。通过对添加了化脓性链球菌的集合唾液进行体外实验,我们测试了各种试剂和洗脱体积,以优化 CandyCollect 设备样本的 RADT 读数。最终的优化方案使用了试剂盒提供的试剂和侧流检测法 (LFA),同时用 CandyCollect 设备取代了试剂盒的咽拭子,减少了洗脱液的体积,并更换了用于洗脱的试管以适应 CandyCollect 设备。用眼睛检测细菌浓度低至制造商规定的 "最低检测限" - 1.5x105 CFU/mL,即可检测出阳性结果。我们还使用图像分析软件对 LFA 试纸条进行扫描和量化,以确定信号与基线比 (SBR),并对阳性检测结果进行分类,避免人为偏见。我们使用 CandyCollect 临床样本测试了 CandyCollect 和 RADT 的优化整合方案,这些样本来自儿科患者(6 人),他们之前通过 RADT 检测咽拭子被诊断为 GAS 咽炎,这也是他们临床治疗的一部分。这些 CandyCollect 设备和穿插的阴性对照的 LFA 结果由独立观察者确定,六名参与者中有四人至少在一次 LFA 复制中获得了阳性结果。综上所述,我们的研究结果表明,可以使用 LFA 快速检测法对来自儿童 GAS 咽炎患者的 CandyCollect 装置进行检测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Reactogenicity and immunogenicity against MPXV of the intradermal administration of Modified V Vaccinia Ankara compared to the standard subcutaneous route. A next generation CRISPR diagnostic tool to survey drug resistance in Human African Trypanosomiasis. Hospital-onset bacteraemia and fungaemia as a novel automated surveillance indicator: results from four European university hospitals Integration of Group A Streptococcus Rapid Tests with the Open Fluidic CandyCollect Device Deep Learning Models for Predicting the Nugent Score to Diagnose Bacterial Vaginosis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1