Andréa El-Khoury , Lawrence Leroux , Julien Dupuis Desroches , Giuseppe Di Labbio , Lyes Kadem
{"title":"Design and validation of an In Vitro test bench for the investigation of cardiopulmonary resuscitation procedure","authors":"Andréa El-Khoury , Lawrence Leroux , Julien Dupuis Desroches , Giuseppe Di Labbio , Lyes Kadem","doi":"10.1016/j.jbiomech.2024.112324","DOIUrl":null,"url":null,"abstract":"<div><p>Despite recent clinical and technological advancements, the cardiac arrest survival rate remains as low as 10%. To enhance patient outcomes, it is crucial to deepen the understanding of cardiopulmonary resuscitation (CPR) at a fundamental level. Currently, there is a lack of knowledge on the physiological effects of CPR, in particular on the hemodynamics in the heart and the great vessels. The design and validation of a dedicated in vitro heart simulator, capable of replicating the physiological response to CPR, holds the potential to provide valuable insights into the fluid dynamics in the heart during CPR but also to be used as a platform for the development and testing of mechanical CPR machines. The main objective of this study is to design and validate the first in vitro heart simulator that can replicate the physiological response during CPR. For that, a custom-made heart simulator is designed consisting of an elastic model of the complete heart and a controllable linear actuator. The heart model is positioned in an anatomical position, and the linear actuator compresses the model at specific rates and depths. Flow and pressure waveforms are recorded on the newly developed simulator at 60 contractions per minute and results are validated against reported in vivo data in the literature. Finally, the system’s capabilities are evaluated by considering several combinations of compression rates and depths.</p></div>","PeriodicalId":15168,"journal":{"name":"Journal of biomechanics","volume":"176 ","pages":"Article 112324"},"PeriodicalIF":2.4000,"publicationDate":"2024-09-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of biomechanics","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0021929024004020","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0
Abstract
Despite recent clinical and technological advancements, the cardiac arrest survival rate remains as low as 10%. To enhance patient outcomes, it is crucial to deepen the understanding of cardiopulmonary resuscitation (CPR) at a fundamental level. Currently, there is a lack of knowledge on the physiological effects of CPR, in particular on the hemodynamics in the heart and the great vessels. The design and validation of a dedicated in vitro heart simulator, capable of replicating the physiological response to CPR, holds the potential to provide valuable insights into the fluid dynamics in the heart during CPR but also to be used as a platform for the development and testing of mechanical CPR machines. The main objective of this study is to design and validate the first in vitro heart simulator that can replicate the physiological response during CPR. For that, a custom-made heart simulator is designed consisting of an elastic model of the complete heart and a controllable linear actuator. The heart model is positioned in an anatomical position, and the linear actuator compresses the model at specific rates and depths. Flow and pressure waveforms are recorded on the newly developed simulator at 60 contractions per minute and results are validated against reported in vivo data in the literature. Finally, the system’s capabilities are evaluated by considering several combinations of compression rates and depths.
期刊介绍:
The Journal of Biomechanics publishes reports of original and substantial findings using the principles of mechanics to explore biological problems. Analytical, as well as experimental papers may be submitted, and the journal accepts original articles, surveys and perspective articles (usually by Editorial invitation only), book reviews and letters to the Editor. The criteria for acceptance of manuscripts include excellence, novelty, significance, clarity, conciseness and interest to the readership.
Papers published in the journal may cover a wide range of topics in biomechanics, including, but not limited to:
-Fundamental Topics - Biomechanics of the musculoskeletal, cardiovascular, and respiratory systems, mechanics of hard and soft tissues, biofluid mechanics, mechanics of prostheses and implant-tissue interfaces, mechanics of cells.
-Cardiovascular and Respiratory Biomechanics - Mechanics of blood-flow, air-flow, mechanics of the soft tissues, flow-tissue or flow-prosthesis interactions.
-Cell Biomechanics - Biomechanic analyses of cells, membranes and sub-cellular structures; the relationship of the mechanical environment to cell and tissue response.
-Dental Biomechanics - Design and analysis of dental tissues and prostheses, mechanics of chewing.
-Functional Tissue Engineering - The role of biomechanical factors in engineered tissue replacements and regenerative medicine.
-Injury Biomechanics - Mechanics of impact and trauma, dynamics of man-machine interaction.
-Molecular Biomechanics - Mechanical analyses of biomolecules.
-Orthopedic Biomechanics - Mechanics of fracture and fracture fixation, mechanics of implants and implant fixation, mechanics of bones and joints, wear of natural and artificial joints.
-Rehabilitation Biomechanics - Analyses of gait, mechanics of prosthetics and orthotics.
-Sports Biomechanics - Mechanical analyses of sports performance.