{"title":"Design and validation of an In Vitro test bench for the investigation of cardiopulmonary resuscitation procedure","authors":"Andréa El-Khoury ,&nbsp;Lawrence Leroux ,&nbsp;Julien Dupuis Desroches ,&nbsp;Giuseppe Di Labbio ,&nbsp;Lyes Kadem","doi":"10.1016/j.jbiomech.2024.112324","DOIUrl":null,"url":null,"abstract":"<div><p>Despite recent clinical and technological advancements, the cardiac arrest survival rate remains as low as 10%. To enhance patient outcomes, it is crucial to deepen the understanding of cardiopulmonary resuscitation (CPR) at a fundamental level. Currently, there is a lack of knowledge on the physiological effects of CPR, in particular on the hemodynamics in the heart and the great vessels. The design and validation of a dedicated in vitro heart simulator, capable of replicating the physiological response to CPR, holds the potential to provide valuable insights into the fluid dynamics in the heart during CPR but also to be used as a platform for the development and testing of mechanical CPR machines. The main objective of this study is to design and validate the first in vitro heart simulator that can replicate the physiological response during CPR. For that, a custom-made heart simulator is designed consisting of an elastic model of the complete heart and a controllable linear actuator. The heart model is positioned in an anatomical position, and the linear actuator compresses the model at specific rates and depths. Flow and pressure waveforms are recorded on the newly developed simulator at 60 contractions per minute and results are validated against reported in vivo data in the literature. Finally, the system’s capabilities are evaluated by considering several combinations of compression rates and depths.</p></div>","PeriodicalId":15168,"journal":{"name":"Journal of biomechanics","volume":"176 ","pages":"Article 112324"},"PeriodicalIF":2.4000,"publicationDate":"2024-09-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of biomechanics","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0021929024004020","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0

Abstract

Despite recent clinical and technological advancements, the cardiac arrest survival rate remains as low as 10%. To enhance patient outcomes, it is crucial to deepen the understanding of cardiopulmonary resuscitation (CPR) at a fundamental level. Currently, there is a lack of knowledge on the physiological effects of CPR, in particular on the hemodynamics in the heart and the great vessels. The design and validation of a dedicated in vitro heart simulator, capable of replicating the physiological response to CPR, holds the potential to provide valuable insights into the fluid dynamics in the heart during CPR but also to be used as a platform for the development and testing of mechanical CPR machines. The main objective of this study is to design and validate the first in vitro heart simulator that can replicate the physiological response during CPR. For that, a custom-made heart simulator is designed consisting of an elastic model of the complete heart and a controllable linear actuator. The heart model is positioned in an anatomical position, and the linear actuator compresses the model at specific rates and depths. Flow and pressure waveforms are recorded on the newly developed simulator at 60 contractions per minute and results are validated against reported in vivo data in the literature. Finally, the system’s capabilities are evaluated by considering several combinations of compression rates and depths.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
设计和验证用于研究心肺复苏程序的体外试验台
尽管近年来临床和技术不断进步,但心脏骤停患者的存活率仍然低至 10%。为了提高患者的治疗效果,从根本上加深对心肺复苏(CPR)的理解至关重要。目前,人们对心肺复苏的生理效应,尤其是对心脏和大血管的血流动力学缺乏了解。专用体外心脏模拟器能够复制心肺复苏术的生理反应,其设计和验证不仅有可能为心肺复苏术期间的心脏流体动力学提供有价值的见解,还可用作开发和测试机械心肺复苏机的平台。本研究的主要目的是设计和验证第一个体外心脏模拟器,该模拟器可以复制心肺复苏过程中的生理反应。为此,我们设计了一个定制的心脏模拟器,由一个完整心脏的弹性模型和一个可控线性致动器组成。将心脏模型置于解剖位置,线性推杆以特定速率和深度压缩模型。在新开发的模拟器上以每分钟 60 次收缩的速度记录流量和压力波形,并根据文献中报告的体内数据对结果进行验证。最后,通过考虑压缩率和深度的几种组合,对系统的能力进行了评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of biomechanics
Journal of biomechanics 生物-工程:生物医学
CiteScore
5.10
自引率
4.20%
发文量
345
审稿时长
1 months
期刊介绍: The Journal of Biomechanics publishes reports of original and substantial findings using the principles of mechanics to explore biological problems. Analytical, as well as experimental papers may be submitted, and the journal accepts original articles, surveys and perspective articles (usually by Editorial invitation only), book reviews and letters to the Editor. The criteria for acceptance of manuscripts include excellence, novelty, significance, clarity, conciseness and interest to the readership. Papers published in the journal may cover a wide range of topics in biomechanics, including, but not limited to: -Fundamental Topics - Biomechanics of the musculoskeletal, cardiovascular, and respiratory systems, mechanics of hard and soft tissues, biofluid mechanics, mechanics of prostheses and implant-tissue interfaces, mechanics of cells. -Cardiovascular and Respiratory Biomechanics - Mechanics of blood-flow, air-flow, mechanics of the soft tissues, flow-tissue or flow-prosthesis interactions. -Cell Biomechanics - Biomechanic analyses of cells, membranes and sub-cellular structures; the relationship of the mechanical environment to cell and tissue response. -Dental Biomechanics - Design and analysis of dental tissues and prostheses, mechanics of chewing. -Functional Tissue Engineering - The role of biomechanical factors in engineered tissue replacements and regenerative medicine. -Injury Biomechanics - Mechanics of impact and trauma, dynamics of man-machine interaction. -Molecular Biomechanics - Mechanical analyses of biomolecules. -Orthopedic Biomechanics - Mechanics of fracture and fracture fixation, mechanics of implants and implant fixation, mechanics of bones and joints, wear of natural and artificial joints. -Rehabilitation Biomechanics - Analyses of gait, mechanics of prosthetics and orthotics. -Sports Biomechanics - Mechanical analyses of sports performance.
期刊最新文献
Effects of knee joint position on the triceps Suræ torque-size relationship during plantarflexion in healthy young adults. Differential T2* changes in tibialis anterior and soleus: Influence of exercise type and perceived exertion. Shear viscoelastic properties of human orbital fat. Société de Biomécanique young investigator award 2023: Estimation of intersegmental load at L5-S1 during lifting/lowering tasks using force plate free markerless motion capture. Changes in lower extremity muscle coordination over a 30-minute walk do not differ by muscle fatigability
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1