Accuracy of robotic computer-assisted implant surgery for immediate implant placement: A retrospective case series study.

Ping Li, Chunhui Zhao, Jiahao Chen, Shulan Xu, Shuo Yang, An Li
{"title":"Accuracy of robotic computer-assisted implant surgery for immediate implant placement: A retrospective case series study.","authors":"Ping Li, Chunhui Zhao, Jiahao Chen, Shulan Xu, Shuo Yang, An Li","doi":"10.1111/cid.13383","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>This study investigated the accuracy of robotic computer-assisted implant surgery (r-CAIS) for immediate implant placement.</p><p><strong>Methods: </strong>Twenty cases with 20 implant sites were selected based on predefined inclusion criteria. The preparation of the implant bed and implant placement followed the standardized dental implant robotic surgery protocol. Postoperative cone-beam computed tomography scans were conducted to assess possible discrepancies between actual and planned implant positions.</p><p><strong>Results: </strong>The r-CAIS technology for immediate implant placement exhibited a mean global coronal deviation of 0.71 ± 0.27 mm (95% CI: 0.58-0.83 mm), a mean global apical deviation of 0.69 ± 0.26 mm (95% CI: 0.56-0.81 mm), and an angular deviation of 1.27 ± 0.47° (95% CI: 1.05-1.49°). A substantial number of deviations were observed buccally at both coronal (90%) and apical (95%) levels, with a consistent tendency for buccal deviation.</p><p><strong>Conclusions: </strong>The r-CAIS technology proved a promising approach for immediate implantation in the anterior region, with satisfactory clinical outcomes. However, an optimized surgical protocol for r-CAIS technology is required for particular implant sites like extraction sockets or bone defects.</p>","PeriodicalId":93944,"journal":{"name":"Clinical implant dentistry and related research","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical implant dentistry and related research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1111/cid.13383","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: This study investigated the accuracy of robotic computer-assisted implant surgery (r-CAIS) for immediate implant placement.

Methods: Twenty cases with 20 implant sites were selected based on predefined inclusion criteria. The preparation of the implant bed and implant placement followed the standardized dental implant robotic surgery protocol. Postoperative cone-beam computed tomography scans were conducted to assess possible discrepancies between actual and planned implant positions.

Results: The r-CAIS technology for immediate implant placement exhibited a mean global coronal deviation of 0.71 ± 0.27 mm (95% CI: 0.58-0.83 mm), a mean global apical deviation of 0.69 ± 0.26 mm (95% CI: 0.56-0.81 mm), and an angular deviation of 1.27 ± 0.47° (95% CI: 1.05-1.49°). A substantial number of deviations were observed buccally at both coronal (90%) and apical (95%) levels, with a consistent tendency for buccal deviation.

Conclusions: The r-CAIS technology proved a promising approach for immediate implantation in the anterior region, with satisfactory clinical outcomes. However, an optimized surgical protocol for r-CAIS technology is required for particular implant sites like extraction sockets or bone defects.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
机器人计算机辅助种植手术对即刻种植体植入的准确性:回顾性病例系列研究。
研究目的本研究探讨了机器人计算机辅助种植手术(r-CAIS)在即刻种植体植入方面的准确性:根据预先确定的纳入标准,选择了 20 个病例的 20 个种植部位。种植床的准备和种植体的植入均按照标准化的牙科种植机器人手术方案进行。术后进行锥形束计算机断层扫描,以评估实际种植体位置与计划种植体位置之间可能存在的差异:r-CAIS技术用于即刻种植体植入的平均冠状偏差为0.71±0.27毫米(95% CI:0.58-0.83毫米),平均根尖偏差为0.69±0.26毫米(95% CI:0.56-0.81毫米),角度偏差为1.27±0.47°(95% CI:1.05-1.49°)。在冠状水平(90%)和根尖水平(95%)均观察到大量颊侧偏差,颊侧偏差趋势一致:r-CAIS技术被证明是前牙区即刻种植的理想方法,临床效果令人满意。然而,对于拔牙窝或骨缺损等特殊种植部位,需要对 r-CAIS 技术的手术方案进行优化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Survival and Success of 3D-Printed Versus Milled Immediate Provisional Full-Arch Restorations: A Retrospective Analysis. Accuracy of Photogrammetry, Intraoral Scanning, and Conventional Impression for Multiple Implants: An In Vitro Study. The Effect of NiTi Brush, Polishing Brush, and Chemical Agent on the Dental Implant Surface Morphology and Cytocompatibility. Transitional implants in computer-assisted implant surgery and fixed complete-arch provisionalization: A retrospective case series. Budget Impact Analysis: Digital Workflow Significantly Reduces Costs of Implant Supported Overdentures (IODs).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1