Observed and expected reliability of echocardiographic volumetric methods and critical change values for quantification of mitral regurgitant fraction in dogs.
Kerry A Loughran, Marc S Kraus, Erin J Achilles, Terry Huh, Éva Larouche-Lebel, Laura K Massey, Anna R Gelzer, Mark A Oyama
{"title":"Observed and expected reliability of echocardiographic volumetric methods and critical change values for quantification of mitral regurgitant fraction in dogs.","authors":"Kerry A Loughran, Marc S Kraus, Erin J Achilles, Terry Huh, Éva Larouche-Lebel, Laura K Massey, Anna R Gelzer, Mark A Oyama","doi":"10.1111/jvim.17205","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Reliability of echocardiographic calculations for stroke volume and mitral regurgitant fraction (RF<sub>MR</sub>) are affected by observer variability and lack of a gold standard. Variability is used to calculate critical change values (CCVs) that are thresholds representing real change in a measure not associated with observer variability.</p><p><strong>Hypothesis: </strong>Observed intra- and interobserver accuracy and variability in healthy dogs help model CCV for RF<sub>MR</sub>.</p><p><strong>Animals: </strong>Reliability cohort of 34 healthy dogs; allometric scaling cohort of 99 dogs with heart disease and 25 healthy dogs.</p><p><strong>Methods: </strong>Accuracy, variability, and CCV of 2 observers using geometric and flow-based echocardiography were prospectively compared against a standard of RF<sub>MR</sub> = 0% and extrapolated across a range of expected RF<sub>MR</sub> values in the reliability cohort partly derived from cardiac dimensions predicted by the allometric cohort.</p><p><strong>Results: </strong>Accuracy of methods to determine RF<sub>MR</sub> in descending order was 4-chamber bullet (Bullet<sub>4CH</sub>), mitral inflow, cube formula, and Simpson's method of disks. Intraobserver variability was relatively high. The CCV for RF<sub>MR</sub> ranged from 28% to 88% and was inversely related to RF<sub>MR</sub> when extrapolated for use in affected dogs. For both observers, the Bullet<sub>4CH</sub> method had the lowest intraobserver CCV (Operator 1:28%, Operator 2:41%). Interobserver strength of agreement was low with intraclass correlation coefficients ranging from 0.210 to 0.413.</p><p><strong>Conclusions and clinical importance: </strong>Echocardiographic volumetric methods used to calculate stroke volume and RF<sub>MR</sub> have low accuracy and high variability in healthy dogs. Extrapolation of observed CCV to a range of expected RF<sub>MR</sub> suggests observers and methods are not interchangeable and variability might hinder routine clinical usage. Individual observers should be aware of their own variability and CCV.</p>","PeriodicalId":17462,"journal":{"name":"Journal of Veterinary Internal Medicine","volume":" ","pages":""},"PeriodicalIF":2.6000,"publicationDate":"2024-09-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Veterinary Internal Medicine","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1111/jvim.17205","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Reliability of echocardiographic calculations for stroke volume and mitral regurgitant fraction (RFMR) are affected by observer variability and lack of a gold standard. Variability is used to calculate critical change values (CCVs) that are thresholds representing real change in a measure not associated with observer variability.
Hypothesis: Observed intra- and interobserver accuracy and variability in healthy dogs help model CCV for RFMR.
Animals: Reliability cohort of 34 healthy dogs; allometric scaling cohort of 99 dogs with heart disease and 25 healthy dogs.
Methods: Accuracy, variability, and CCV of 2 observers using geometric and flow-based echocardiography were prospectively compared against a standard of RFMR = 0% and extrapolated across a range of expected RFMR values in the reliability cohort partly derived from cardiac dimensions predicted by the allometric cohort.
Results: Accuracy of methods to determine RFMR in descending order was 4-chamber bullet (Bullet4CH), mitral inflow, cube formula, and Simpson's method of disks. Intraobserver variability was relatively high. The CCV for RFMR ranged from 28% to 88% and was inversely related to RFMR when extrapolated for use in affected dogs. For both observers, the Bullet4CH method had the lowest intraobserver CCV (Operator 1:28%, Operator 2:41%). Interobserver strength of agreement was low with intraclass correlation coefficients ranging from 0.210 to 0.413.
Conclusions and clinical importance: Echocardiographic volumetric methods used to calculate stroke volume and RFMR have low accuracy and high variability in healthy dogs. Extrapolation of observed CCV to a range of expected RFMR suggests observers and methods are not interchangeable and variability might hinder routine clinical usage. Individual observers should be aware of their own variability and CCV.
期刊介绍:
The mission of the Journal of Veterinary Internal Medicine is to advance veterinary medical knowledge and improve the lives of animals by publication of authoritative scientific articles of animal diseases.