Comparison of amount of noise and elimination strategies for noise in neonatal intensive care units of government and private hospitals in the Jodhpur district of India.

IF 1.8 4区 医学 Q2 PEDIATRICS Journal of Tropical Pediatrics Pub Date : 2024-08-10 DOI:10.1093/tropej/fmae032
Prateek Lokwani, Niharika Mathur, Neeraj Gupta, Sushil Kumar Choudhary, Arun Kumarendu Singh
{"title":"Comparison of amount of noise and elimination strategies for noise in neonatal intensive care units of government and private hospitals in the Jodhpur district of India.","authors":"Prateek Lokwani, Niharika Mathur, Neeraj Gupta, Sushil Kumar Choudhary, Arun Kumarendu Singh","doi":"10.1093/tropej/fmae032","DOIUrl":null,"url":null,"abstract":"<p><p>With technological advancement, neonatal intensive care units (NICUs) have become noisier than ever. Studies have shown the detrimental effects of increasing noise in NICU on growing pre-term and sick neonates. The present study aimed primarily to compare the amount of noise in NICUs of private and government hospitals. The secondary aim was to compare the strategies adopted by these hospitals to control the detrimental effects of noise on newborns. A detailed noise survey was conducted in the NICUs of two private and two government hospitals in the Jodhpur district, India. The noise survey was performed for a duration of 48 h using \"Sound Ear 3-300\" noise meters. The analyses were measured in Leq (equivalent continuous sound level) A-weighted decibels (dBA). The extracted data analysis revealed that the noise measured was in the range of 61.62-82.32 dBA in four NICUs of the district. The results also revealed a statistically significant difference between the NICU noise of private and government hospitals. The levels of alarming sounds differed between the hospitals with a general trend of lesser alarming sounds in private hospitals. The major differences in strategies adopted were that both private hospitals had a protocol to purposely reduce levels of alarming sounds when heard, and purposely limited the number of staff present in certain areas of the NICU, which were correlated with reduced sound compared to the government hospitals. Strategies like these require no additional cost to make drastic changes in the average noise measured.</p>","PeriodicalId":17521,"journal":{"name":"Journal of Tropical Pediatrics","volume":null,"pages":null},"PeriodicalIF":1.8000,"publicationDate":"2024-08-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Tropical Pediatrics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/tropej/fmae032","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PEDIATRICS","Score":null,"Total":0}
引用次数: 0

Abstract

With technological advancement, neonatal intensive care units (NICUs) have become noisier than ever. Studies have shown the detrimental effects of increasing noise in NICU on growing pre-term and sick neonates. The present study aimed primarily to compare the amount of noise in NICUs of private and government hospitals. The secondary aim was to compare the strategies adopted by these hospitals to control the detrimental effects of noise on newborns. A detailed noise survey was conducted in the NICUs of two private and two government hospitals in the Jodhpur district, India. The noise survey was performed for a duration of 48 h using "Sound Ear 3-300" noise meters. The analyses were measured in Leq (equivalent continuous sound level) A-weighted decibels (dBA). The extracted data analysis revealed that the noise measured was in the range of 61.62-82.32 dBA in four NICUs of the district. The results also revealed a statistically significant difference between the NICU noise of private and government hospitals. The levels of alarming sounds differed between the hospitals with a general trend of lesser alarming sounds in private hospitals. The major differences in strategies adopted were that both private hospitals had a protocol to purposely reduce levels of alarming sounds when heard, and purposely limited the number of staff present in certain areas of the NICU, which were correlated with reduced sound compared to the government hospitals. Strategies like these require no additional cost to make drastic changes in the average noise measured.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
印度焦特布尔地区公立医院和私立医院新生儿重症监护室噪音量和消除噪音策略的比较。
随着技术的进步,新生儿重症监护室(NICU)变得比以往任何时候都更加嘈杂。研究表明,新生儿重症监护室噪音的增加会对早产儿和患病新生儿的成长造成不利影响。本研究的主要目的是比较私立医院和公立医院新生儿重症监护室的噪音量。其次是比较这些医院为控制噪音对新生儿的不利影响而采取的策略。对印度焦特布尔地区两家私立医院和两家公立医院的新生儿重症监护室进行了详细的噪音调查。噪声调查使用 "声耳 3-300 "噪声计进行,持续时间为 48 小时。分析以 Leq(等效连续声级)A 加权分贝 (dBA) 为单位进行测量。提取的数据分析显示,该区四所新生儿重症监护室测得的噪声范围为 61.62-82.32 dBA。结果还显示,私立医院和公立医院的新生儿重症监护室噪音在统计学上存在显著差异。不同医院的警报声水平不同,总体趋势是私立医院的警报声较小。所采取策略的主要区别在于,两家私立医院都制定了一项规程,在听到警报声时有意降低警报声的水平,并有意限制新生儿重症监护室某些区域的工作人员人数。这些策略无需额外成本,就能使测得的平均噪音发生巨大变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Tropical Pediatrics
Journal of Tropical Pediatrics 医学-热带医学
CiteScore
4.00
自引率
0.00%
发文量
97
审稿时长
6-12 weeks
期刊介绍: The Journal of Tropical Pediatrics provides a link between theory and practice in the field. Papers report key results of clinical and community research, and considerations of programme development. More general descriptive pieces are included when they have application to work preceeding elsewhere. The journal also presents review articles, book reviews and, occasionally, short monographs and selections of important papers delivered at relevant conferences.
期刊最新文献
SimCapture app video performance assessment versus real-time instructor-based performance evaluation of undergraduates in neonatal resuscitation-an agreement study. Duration of a standard phototherapy course in jaundiced newborns with no neurotoxicity risk. Role of aminophylline in prevention of acute kidney injury in term neonates with severe perinatal asphyxia: a randomized open-label controlled trial. A systematic review of pelvic infective osteomyelitis in children: current state of evidence. Adenovirus respiratory infection with severe pneumonia in hospitalized children: a case series.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1