Liu-Jia Sun, Qing-Bang Han, Cheng Yin, Qi-Lin Jin, Kao Ge
{"title":"Research on the fusion imaging method of sign coherence and time reversal for Lamb wave sparse array","authors":"Liu-Jia Sun, Qing-Bang Han, Cheng Yin, Qi-Lin Jin, Kao Ge","doi":"10.1016/j.ultras.2024.107489","DOIUrl":null,"url":null,"abstract":"<div><div>Time-reversal imaging struggles to detect plate-like structures due to interference from Lamb wave mode conversion and the processing demands, leading to less effective outcomes. This paper proposes a sign coherence factor and time reversal fusion (SCF-TR) imaging method based on amplitude and phase estimation. This method removes the coherence of array signals during signal reversal and refocusing. It reintroduces the sign coherence component to reduce interference from non-target scattered waves and partially overcome the constraints imposed by the Rayleigh criterion. The method allows imaging at a resolution smaller than the wavelength of Lamb and enhances the quality of the resulting images. In addition, a sparse array design utilizing the White Shark Optimisation Algorithm (WSO) is proposed to streamline the SCF-TR calculation process. This design utilizes sparse full matrix data to improve imaging efficiency. The experimental results show that for single blind hole defects, the SCF-TR method improves the array performance metrics and signal-to-noise ratio by 22.46% and 42.50%, respectively, compared to the TR method. For multiple asymmetric blind hole defects, when the defect size exceeds the resolution threshold, SCF-TR accurately reflects the position and morphology of defects smaller than the wavelength. When the defect size is below the resolution threshold, SCF-TR achieves super-resolution imaging. The sparse array designed using the White Shark Optimization algorithm demonstrates good sidelobe characteristics, effectively reducing sidelobe noise without reducing the array aperture. Moreover, the SCF-TR imaging time is reduced by approximately half while maintaining imaging accuracy.</div></div>","PeriodicalId":23522,"journal":{"name":"Ultrasonics","volume":null,"pages":null},"PeriodicalIF":3.8000,"publicationDate":"2024-10-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasonics","FirstCategoryId":"101","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0041624X2400252X","RegionNum":2,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0
Abstract
Time-reversal imaging struggles to detect plate-like structures due to interference from Lamb wave mode conversion and the processing demands, leading to less effective outcomes. This paper proposes a sign coherence factor and time reversal fusion (SCF-TR) imaging method based on amplitude and phase estimation. This method removes the coherence of array signals during signal reversal and refocusing. It reintroduces the sign coherence component to reduce interference from non-target scattered waves and partially overcome the constraints imposed by the Rayleigh criterion. The method allows imaging at a resolution smaller than the wavelength of Lamb and enhances the quality of the resulting images. In addition, a sparse array design utilizing the White Shark Optimisation Algorithm (WSO) is proposed to streamline the SCF-TR calculation process. This design utilizes sparse full matrix data to improve imaging efficiency. The experimental results show that for single blind hole defects, the SCF-TR method improves the array performance metrics and signal-to-noise ratio by 22.46% and 42.50%, respectively, compared to the TR method. For multiple asymmetric blind hole defects, when the defect size exceeds the resolution threshold, SCF-TR accurately reflects the position and morphology of defects smaller than the wavelength. When the defect size is below the resolution threshold, SCF-TR achieves super-resolution imaging. The sparse array designed using the White Shark Optimization algorithm demonstrates good sidelobe characteristics, effectively reducing sidelobe noise without reducing the array aperture. Moreover, the SCF-TR imaging time is reduced by approximately half while maintaining imaging accuracy.
期刊介绍:
Ultrasonics is the only internationally established journal which covers the entire field of ultrasound research and technology and all its many applications. Ultrasonics contains a variety of sections to keep readers fully informed and up-to-date on the whole spectrum of research and development throughout the world. Ultrasonics publishes papers of exceptional quality and of relevance to both academia and industry. Manuscripts in which ultrasonics is a central issue and not simply an incidental tool or minor issue, are welcomed.
As well as top quality original research papers and review articles by world renowned experts, Ultrasonics also regularly features short communications, a calendar of forthcoming events and special issues dedicated to topical subjects.