{"title":"Validity of IMU sensors for assessing features of walking in laboratory and outdoor environments among older adults","authors":"Emmi Matikainen-Tervola , Neil Cronin , Eeva Aartolahti , Sanna Sihvonen , Sailee Sansgiri , Taija Finni , Olli-Pekka Mattila , Merja Rantakokko","doi":"10.1016/j.gaitpost.2024.10.013","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><div>IMU sensors (three-dimensional accelerometer, gyroscope and magnetometer) enable assessment of walking in older adults outside the laboratory. We studied whether IMUs are valid for detecting walking parameters (step events, time, length, and cadence) in a laboratory and outdoors on a level surface in older adults.</div></div><div><h3>Methods</h3><div>This validation study is part of a larger cross-sectional study. Twenty-six participants (mean age 76 years, 65 % female) walked on a treadmill indoors and on a sport track outdoors at self-selected speed. IMUs were attached laterally on the shanks and on the lower back at the level of L3-L4. Initial contact (IC) and step lengths were also estimated using acceleration signals (vertical, antero-posterior) from the pelvic IMU. Terminal contact (TC) was determined from the shank IMU sagittal angular velocity. For step length, inverted pendulum model and participant’s leg length (0.53 x height) was used. Step duration was calculated from IC to the opposite leg IC and stride duration from IC to next ipsilateral IC. Cadence was calculated as steps/min. As reference data, 3D motion capture was used in the laboratory and a high-speed video camera outdoors. Intraclass correlation coefficients (ICC), root mean squared errors (RMSE), typical errors and Bland-Altman plots were calculated and drawn.</div></div><div><h3>Results</h3><div>When comparing IC timing between IMU and reference data, mean bias was 0.031 s in the laboratory and −0.004 s outdoors, and for TC −0.057 s and −0.070 s respectively. Step and stride duration and cadence showed ICC values >0.80 and mean bias was <0.005 s for step and stride durations and <0.05 steps/min for cadence in both environments. Step length ICC values were <0.40 in the laboratory and outdoors.</div></div><div><h3>Significance</h3><div>IMUs can be used to monitor temporal walking variables in older adults and may be useful for rehabilitation interventions and functional capacity assessment.</div></div>","PeriodicalId":12496,"journal":{"name":"Gait & posture","volume":"114 ","pages":"Pages 277-283"},"PeriodicalIF":2.2000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Gait & posture","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0966636224006416","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"NEUROSCIENCES","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction
IMU sensors (three-dimensional accelerometer, gyroscope and magnetometer) enable assessment of walking in older adults outside the laboratory. We studied whether IMUs are valid for detecting walking parameters (step events, time, length, and cadence) in a laboratory and outdoors on a level surface in older adults.
Methods
This validation study is part of a larger cross-sectional study. Twenty-six participants (mean age 76 years, 65 % female) walked on a treadmill indoors and on a sport track outdoors at self-selected speed. IMUs were attached laterally on the shanks and on the lower back at the level of L3-L4. Initial contact (IC) and step lengths were also estimated using acceleration signals (vertical, antero-posterior) from the pelvic IMU. Terminal contact (TC) was determined from the shank IMU sagittal angular velocity. For step length, inverted pendulum model and participant’s leg length (0.53 x height) was used. Step duration was calculated from IC to the opposite leg IC and stride duration from IC to next ipsilateral IC. Cadence was calculated as steps/min. As reference data, 3D motion capture was used in the laboratory and a high-speed video camera outdoors. Intraclass correlation coefficients (ICC), root mean squared errors (RMSE), typical errors and Bland-Altman plots were calculated and drawn.
Results
When comparing IC timing between IMU and reference data, mean bias was 0.031 s in the laboratory and −0.004 s outdoors, and for TC −0.057 s and −0.070 s respectively. Step and stride duration and cadence showed ICC values >0.80 and mean bias was <0.005 s for step and stride durations and <0.05 steps/min for cadence in both environments. Step length ICC values were <0.40 in the laboratory and outdoors.
Significance
IMUs can be used to monitor temporal walking variables in older adults and may be useful for rehabilitation interventions and functional capacity assessment.
期刊介绍:
Gait & Posture is a vehicle for the publication of up-to-date basic and clinical research on all aspects of locomotion and balance.
The topics covered include: Techniques for the measurement of gait and posture, and the standardization of results presentation; Studies of normal and pathological gait; Treatment of gait and postural abnormalities; Biomechanical and theoretical approaches to gait and posture; Mathematical models of joint and muscle mechanics; Neurological and musculoskeletal function in gait and posture; The evolution of upright posture and bipedal locomotion; Adaptations of carrying loads, walking on uneven surfaces, climbing stairs etc; spinal biomechanics only if they are directly related to gait and/or posture and are of general interest to our readers; The effect of aging and development on gait and posture; Psychological and cultural aspects of gait; Patient education.