Jon F Rischewski, Florian T Gassert, Theresa Urban, Johannes Hammel, Alexander Kufner, Christian Braun, Maximilian Lochschmidt, Marcus R Makowski, Daniela Pfeiffer, Alexandra S Gersing, Franz Pfeiffer
{"title":"Dark-field radiography for the detection of bone microstructure changes in osteoporotic human lumbar spine specimens.","authors":"Jon F Rischewski, Florian T Gassert, Theresa Urban, Johannes Hammel, Alexander Kufner, Christian Braun, Maximilian Lochschmidt, Marcus R Makowski, Daniela Pfeiffer, Alexandra S Gersing, Franz Pfeiffer","doi":"10.1186/s41747-024-00524-3","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Dark-field radiography imaging exploits the wave character of x-rays to measure small-angle scattering on material interfaces, providing structural information with low radiation exposure. We explored the potential of dark-field imaging of bone microstructure to improve the assessment of bone strength in osteoporosis.</p><p><strong>Methods: </strong>We prospectively examined 14 osteoporotic/osteopenic and 21 non-osteoporotic/osteopenic human cadaveric vertebrae (L2-L4) with a clinical dark-field radiography system, micro-computed tomography (CT), and spectral CT. Dark-field images were obtained in both vertical and horizontal sample positions. Bone microstructural parameters (trabecular number, Tb.N; trabecular thickness, Tb.Th; bone volume fraction, BV/TV; degree of anisotropy, DA) were measured using standard ex vivo micro-CT, while hydroxyapatite density was measured using spectral CT. Correlations were assessed using Spearman rank correlation coefficients.</p><p><strong>Results: </strong>The measured dark-field signal was lower in osteoporotic/osteopenic vertebrae (vertical position, 0.23 ± 0.05 versus 0.29 ± 0.04, p < 0.001; horizontal position, 0.28 ± 0.06 versus 0.34 ± 0.04, p = 0.003). The dark-field signal from the vertical position correlated significantly with Tb.N (ρ = 0.46, p = 0.005), BV/TV (ρ = 0.45, p = 0.007), DA (ρ = -0.43, p = 0.010), and hydroxyapatite density (ρ = 0.53, p = 0.010). The calculated ratio of vertical/horizontal dark-field signal correlated significantly with Tb.N (ρ = 0.43, p = 0.011), BV/TV (ρ = 0.36, p = 0.032), DA (ρ = -0.51, p = 0.002), and hydroxyapatite density (ρ = 0.42, p = 0.049).</p><p><strong>Conclusion: </strong>Dark-field radiography is a feasible modality for drawing conclusions on bone microarchitecture in human cadaveric vertebral bone.</p><p><strong>Relevance statement: </strong>Gaining knowledge of the microarchitecture of bone contributes crucially to predicting bone strength in osteoporosis. This novel radiographic approach based on dark-field x-rays provides insights into bone microstructure at a lower radiation exposure than that of CT modalities.</p><p><strong>Key points: </strong>Dark-field radiography can give information on bone microstructure with low radiation exposure. The dark-field signal correlated positively with bone microstructure parameters. Dark-field signal correlated negatively with the degree of anisotropy. Dark-field radiography helps to determine the directionality of trabecular loss.</p>","PeriodicalId":36926,"journal":{"name":"European Radiology Experimental","volume":"8 1","pages":"125"},"PeriodicalIF":3.7000,"publicationDate":"2024-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11534944/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Radiology Experimental","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s41747-024-00524-3","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Dark-field radiography imaging exploits the wave character of x-rays to measure small-angle scattering on material interfaces, providing structural information with low radiation exposure. We explored the potential of dark-field imaging of bone microstructure to improve the assessment of bone strength in osteoporosis.
Methods: We prospectively examined 14 osteoporotic/osteopenic and 21 non-osteoporotic/osteopenic human cadaveric vertebrae (L2-L4) with a clinical dark-field radiography system, micro-computed tomography (CT), and spectral CT. Dark-field images were obtained in both vertical and horizontal sample positions. Bone microstructural parameters (trabecular number, Tb.N; trabecular thickness, Tb.Th; bone volume fraction, BV/TV; degree of anisotropy, DA) were measured using standard ex vivo micro-CT, while hydroxyapatite density was measured using spectral CT. Correlations were assessed using Spearman rank correlation coefficients.
Results: The measured dark-field signal was lower in osteoporotic/osteopenic vertebrae (vertical position, 0.23 ± 0.05 versus 0.29 ± 0.04, p < 0.001; horizontal position, 0.28 ± 0.06 versus 0.34 ± 0.04, p = 0.003). The dark-field signal from the vertical position correlated significantly with Tb.N (ρ = 0.46, p = 0.005), BV/TV (ρ = 0.45, p = 0.007), DA (ρ = -0.43, p = 0.010), and hydroxyapatite density (ρ = 0.53, p = 0.010). The calculated ratio of vertical/horizontal dark-field signal correlated significantly with Tb.N (ρ = 0.43, p = 0.011), BV/TV (ρ = 0.36, p = 0.032), DA (ρ = -0.51, p = 0.002), and hydroxyapatite density (ρ = 0.42, p = 0.049).
Conclusion: Dark-field radiography is a feasible modality for drawing conclusions on bone microarchitecture in human cadaveric vertebral bone.
Relevance statement: Gaining knowledge of the microarchitecture of bone contributes crucially to predicting bone strength in osteoporosis. This novel radiographic approach based on dark-field x-rays provides insights into bone microstructure at a lower radiation exposure than that of CT modalities.
Key points: Dark-field radiography can give information on bone microstructure with low radiation exposure. The dark-field signal correlated positively with bone microstructure parameters. Dark-field signal correlated negatively with the degree of anisotropy. Dark-field radiography helps to determine the directionality of trabecular loss.