Feasibility of creating a daily adaptive plan using automatic DIR-created target and OARs contours in patients with prostate cancer magnetic-resonance-guided adaptive radiotherapy.

IF 1.9 4区 医学 Q2 BIOLOGY Journal of Radiation Research Pub Date : 2024-11-11 DOI:10.1093/jrr/rrae088
Makoto Saito, Kota Abe, Masato Tsuneda, Yukio Fujita, Yukinao Abe, Tsumugi Nishimura, Asuka Kodate, Aki Kanazawa, Rintaro Harada, Miho Watanabe, Takashi Uno
{"title":"Feasibility of creating a daily adaptive plan using automatic DIR-created target and OARs contours in patients with prostate cancer magnetic-resonance-guided adaptive radiotherapy.","authors":"Makoto Saito, Kota Abe, Masato Tsuneda, Yukio Fujita, Yukinao Abe, Tsumugi Nishimura, Asuka Kodate, Aki Kanazawa, Rintaro Harada, Miho Watanabe, Takashi Uno","doi":"10.1093/jrr/rrae088","DOIUrl":null,"url":null,"abstract":"<p><p>The purpose of this study was to evaluate the feasibility of treatment plans for prostate cancer with magnetic resonance (MR)-guided online adaptive radiotherapy, which are generated using deformable image registration (DIR)-created contours of the targets and organs. Totally, 150 fractions from 30 prostate cancer patients implanted with a hydrogel spacer and treated with the MR-Linac were studied. Reference treatment plans that satisfied all institutional dose constraints were initially created on planning MRI. The adaptive treatment plans were created on daily MRI based on the reference plan using the DIR-created contours, ensuring all dose constraints were met. Subsequently, a clinician manually created reference contours for each daily MRI. Finally, the dose volume histogram indices of the plan generated with DIR-created contours were re-evaluated with clinician created contours. The evaluated contours included the bladder wall, rectum wall, sigmoid, small bowel and planning target volume (PTV) for dose prescription. The PTV for dose prescription met the dose constraints in all fractions. The bladder and rectum walls met the dose constraint of maximum dose (D0.03 cc) in all fractions. Five patients failed to meet the sigmoid and small bowel dose constraints, with the largest deviation being 13.3% exceedance at D2 cc in the small bowel added 3 mm margin. This study suggests that most treatment plans created without modifying the DIR-created contours are clinically viable. However, dislodgements of the small bowel and sigmoid may exceed the extent of DIR propagation from the reference plan contours, and it is recommended that these contours be verified.</p>","PeriodicalId":16922,"journal":{"name":"Journal of Radiation Research","volume":" ","pages":""},"PeriodicalIF":1.9000,"publicationDate":"2024-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Radiation Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/jrr/rrae088","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

The purpose of this study was to evaluate the feasibility of treatment plans for prostate cancer with magnetic resonance (MR)-guided online adaptive radiotherapy, which are generated using deformable image registration (DIR)-created contours of the targets and organs. Totally, 150 fractions from 30 prostate cancer patients implanted with a hydrogel spacer and treated with the MR-Linac were studied. Reference treatment plans that satisfied all institutional dose constraints were initially created on planning MRI. The adaptive treatment plans were created on daily MRI based on the reference plan using the DIR-created contours, ensuring all dose constraints were met. Subsequently, a clinician manually created reference contours for each daily MRI. Finally, the dose volume histogram indices of the plan generated with DIR-created contours were re-evaluated with clinician created contours. The evaluated contours included the bladder wall, rectum wall, sigmoid, small bowel and planning target volume (PTV) for dose prescription. The PTV for dose prescription met the dose constraints in all fractions. The bladder and rectum walls met the dose constraint of maximum dose (D0.03 cc) in all fractions. Five patients failed to meet the sigmoid and small bowel dose constraints, with the largest deviation being 13.3% exceedance at D2 cc in the small bowel added 3 mm margin. This study suggests that most treatment plans created without modifying the DIR-created contours are clinically viable. However, dislodgements of the small bowel and sigmoid may exceed the extent of DIR propagation from the reference plan contours, and it is recommended that these contours be verified.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在前列腺癌磁共振引导自适应放疗患者中使用 DIR 自动创建的目标和 OARs 轮廓创建每日自适应计划的可行性。
这项研究的目的是评估利用磁共振(MR)引导的在线自适应放疗治疗前列腺癌计划的可行性,该计划是利用可变形图像配准(DIR)创建的目标和器官轮廓生成的。共研究了 30 名植入水凝胶垫片并接受 MR-Linac 治疗的前列腺癌患者的 150 个分段。最初在规划核磁共振成像时创建了满足所有机构剂量限制的参考治疗计划。使用 DIR 创建的轮廓,根据参考计划在每日 MRI 上创建自适应治疗计划,确保满足所有剂量限制。随后,临床医生为每台每日 MRI 手动创建参考轮廓。最后,使用临床医生创建的轮廓对使用 DIR 创建的轮廓生成的计划的剂量体积直方图指数进行重新评估。评估的轮廓包括膀胱壁、直肠壁、乙状结肠、小肠和剂量处方的规划目标体积(PTV)。用于剂量处方的 PTV 符合所有分段的剂量限制。膀胱壁和直肠壁在所有分次中都符合最大剂量(D0.03 cc)的剂量限制。有五名患者未能达到乙状结肠和小肠的剂量限制,其中最大的偏差是小肠的 D2 cc 超标了 13.3%,边缘增加了 3 毫米。这项研究表明,大多数不修改 DIR 创建轮廓的治疗方案在临床上都是可行的。但是,小肠和乙状结肠的移位可能会超出参考计划轮廓的 DIR 传播范围,因此建议对这些轮廓进行验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.60
自引率
5.00%
发文量
86
审稿时长
4-8 weeks
期刊介绍: The Journal of Radiation Research (JRR) is an official journal of The Japanese Radiation Research Society (JRRS), and the Japanese Society for Radiation Oncology (JASTRO). Since its launch in 1960 as the official journal of the JRRS, the journal has published scientific articles in radiation science in biology, chemistry, physics, epidemiology, and environmental sciences. JRR broadened its scope to include oncology in 2009, when JASTRO partnered with the JRRS to publish the journal. Articles considered fall into two broad categories: Oncology & Medicine - including all aspects of research with patients that impacts on the treatment of cancer using radiation. Papers which cover related radiation therapies, radiation dosimetry, and those describing the basis for treatment methods including techniques, are also welcomed. Clinical case reports are not acceptable. Radiation Research - basic science studies of radiation effects on livings in the area of physics, chemistry, biology, epidemiology and environmental sciences. Please be advised that JRR does not accept any papers of pure physics or chemistry. The journal is bimonthly, and is edited and published by the JRR Editorial Committee.
期刊最新文献
Characterization of acrylic phantom for use in quality assurance of BNCT beam output procedure. Cost-effectiveness analysis for multi adverse events of proton beam therapy for pediatric medulloblastoma in Japan. Feasibility of creating a daily adaptive plan using automatic DIR-created target and OARs contours in patients with prostate cancer magnetic-resonance-guided adaptive radiotherapy. Prophylactic cranial irradiation for limited-stage small-cell lung cancer in the modern magnetic resonance imaging era may be omitted: a propensity score-matched analysis. Elevated α/β ratio after hypofractionated radiotherapy correlated with DNA damage repairment in an experimental model of prostate cancer.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1