Multiphoton scaling of femtosecond laser-induced refractive index change (LIRIC) in hydrogels and rabbit cornea.

IF 2.9 2区 医学 Q2 BIOCHEMICAL RESEARCH METHODS Biomedical optics express Pub Date : 2024-10-08 eCollection Date: 2024-11-01 DOI:10.1364/BOE.537705
Kaitlin T Wozniak, Zachary A Manning, Ruiting Huang, Steven Cox, Sam C Butler, Sebastian Ferlo, Len Zheleznyak, Lisen Xu, Jonathan D Ellis, Krystel R Huxlin, Wayne H Knox
{"title":"Multiphoton scaling of femtosecond laser-induced refractive index change (LIRIC) in hydrogels and rabbit cornea.","authors":"Kaitlin T Wozniak, Zachary A Manning, Ruiting Huang, Steven Cox, Sam C Butler, Sebastian Ferlo, Len Zheleznyak, Lisen Xu, Jonathan D Ellis, Krystel R Huxlin, Wayne H Knox","doi":"10.1364/BOE.537705","DOIUrl":null,"url":null,"abstract":"<p><p>To find optimal conditions for performing laser induced refractive index change (LIRIC) in living eyes with both safety and efficacy, we investigated multiphoton excitation scaling of this procedure in hydrogel and excised corneal tissue. Three distinct wavelength modalities were examined: high-repetition-rate (HRR) and low-repetition-rate (LRR) 405 nm systems, as well as 800 nm and 1035 nm systems, whose LIRIC-inducing properties are described for the first time. Of all the systems, LRR 405 nm-LIRIC was able to produce the highest phase shifts at the lowest average laser powers. Relative merits and drawbacks to each modality are discussed as they relate to future efforts towards LIRIC-based refractive error correction in humans.</p>","PeriodicalId":8969,"journal":{"name":"Biomedical optics express","volume":"15 11","pages":"6242-6258"},"PeriodicalIF":2.9000,"publicationDate":"2024-10-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11563327/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical optics express","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1364/BOE.537705","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/11/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

To find optimal conditions for performing laser induced refractive index change (LIRIC) in living eyes with both safety and efficacy, we investigated multiphoton excitation scaling of this procedure in hydrogel and excised corneal tissue. Three distinct wavelength modalities were examined: high-repetition-rate (HRR) and low-repetition-rate (LRR) 405 nm systems, as well as 800 nm and 1035 nm systems, whose LIRIC-inducing properties are described for the first time. Of all the systems, LRR 405 nm-LIRIC was able to produce the highest phase shifts at the lowest average laser powers. Relative merits and drawbacks to each modality are discussed as they relate to future efforts towards LIRIC-based refractive error correction in humans.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
水凝胶和兔子角膜中飞秒激光诱导折射率变化(LIRIC)的多光子缩放。
为了找到在活体眼球中进行激光诱导屈光度变化(LIRIC)的最佳条件,并确保其安全性和有效性,我们研究了在水凝胶和切除角膜组织中进行该过程的多光子激发缩放。我们研究了三种不同的波长模式:高重复率(HRR)和低重复率(LRR)405 nm 系统,以及 800 nm 和 1035 nm 系统。在所有系统中,LRR 405 nm-LIRIC 能够以最低的平均激光功率产生最大的相移。本文讨论了每种模式的相对优点和缺点,它们关系到未来基于 LIRIC 的人类屈光不正矫正工作。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Biomedical optics express
Biomedical optics express BIOCHEMICAL RESEARCH METHODS-OPTICS
CiteScore
6.80
自引率
11.80%
发文量
633
审稿时长
1 months
期刊介绍: The journal''s scope encompasses fundamental research, technology development, biomedical studies and clinical applications. BOEx focuses on the leading edge topics in the field, including: Tissue optics and spectroscopy Novel microscopies Optical coherence tomography Diffuse and fluorescence tomography Photoacoustic and multimodal imaging Molecular imaging and therapies Nanophotonic biosensing Optical biophysics/photobiology Microfluidic optical devices Vision research.
期刊最新文献
Super resolution reconstruction of fluorescence microscopy images by a convolutional network with physical priors. Physics-guided deep learning-based real-time image reconstruction of Fourier-domain optical coherence tomography. On bench evaluation of intraocular lenses: performance of a commercial interferometer. Predictive coding compressive sensing optical coherence tomography hardware implementation. Development of silicone-based phantoms for biomedical optics from 400 to 1550 nm.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1