Xiang Cheng , Jin Lin , Mingjun Zhang , Liandong Sha , Bosen Yang , Feng Liu , Yonghua Song
{"title":"Power controller design for electrolysis systems with DC/DC interface supporting fast dynamic operation: A model-based and experimental study","authors":"Xiang Cheng , Jin Lin , Mingjun Zhang , Liandong Sha , Bosen Yang , Feng Liu , Yonghua Song","doi":"10.1016/j.apenergy.2024.124848","DOIUrl":null,"url":null,"abstract":"<div><div>The ability of the electrolysis system, powered by fluctuating and intermittent renewable sources, to rapidly and accurately track power signals is crucial for energy management in renewable power-to-hydrogen (ReP2H) plants and for providing grid frequency regulation as a virtual power plant (VPP). However, there is a considerable lag (several seconds or even more than 20 s) between the changes of the stack power compared with the stack current, mainly due to the existence of the electric double-layer (EDL) effect. This characteristic hinders the further application of electrolysis systems as flexible loads in power grids. By designing a suitable power controller in the power-electronics interface directly connected to the stack to replace the traditional current controller, it is expected to improve the fast dynamic response of the stack power. This paper proposes a unified electrical equivalent circuit for alkaline water electrolysis (AWE) systems and proton exchange membrane (PEM) electrolysis system with detailed parallel Buck type DC/DC interface, which considers the EDL effect and nonlinear behaviors of electrolysis systems and is suitable for controller design. A power controller design and robust parameter tuning method without excessive current overshoot based on frequency-domain analysis is proposed. The accuracy and effectiveness of the proposed model and method are verified by the experimental test on the 2 N m<span><math><msup><mrow></mrow><mrow><mn>3</mn></mrow></msup></math></span>/h(10 kW) AWE system and the 1 N m<span><math><msup><mrow></mrow><mrow><mn>3</mn></mrow></msup></math></span>/h(5 kW) PEM electrolysis system. With the proposed power controller, the AWE and PEM electrolysis system can change the stack power within 0.266s and 0.21s respectively, meeting the requirements of energy management and frequency regulation. Additionally, the temperature stability and the sensitivity of the proposed method to parameter fluctuations in the stack and DC/DC interface are analyzed.</div></div>","PeriodicalId":246,"journal":{"name":"Applied Energy","volume":"378 ","pages":"Article 124848"},"PeriodicalIF":10.1000,"publicationDate":"2024-11-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Energy","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0306261924022311","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0
Abstract
The ability of the electrolysis system, powered by fluctuating and intermittent renewable sources, to rapidly and accurately track power signals is crucial for energy management in renewable power-to-hydrogen (ReP2H) plants and for providing grid frequency regulation as a virtual power plant (VPP). However, there is a considerable lag (several seconds or even more than 20 s) between the changes of the stack power compared with the stack current, mainly due to the existence of the electric double-layer (EDL) effect. This characteristic hinders the further application of electrolysis systems as flexible loads in power grids. By designing a suitable power controller in the power-electronics interface directly connected to the stack to replace the traditional current controller, it is expected to improve the fast dynamic response of the stack power. This paper proposes a unified electrical equivalent circuit for alkaline water electrolysis (AWE) systems and proton exchange membrane (PEM) electrolysis system with detailed parallel Buck type DC/DC interface, which considers the EDL effect and nonlinear behaviors of electrolysis systems and is suitable for controller design. A power controller design and robust parameter tuning method without excessive current overshoot based on frequency-domain analysis is proposed. The accuracy and effectiveness of the proposed model and method are verified by the experimental test on the 2 N m/h(10 kW) AWE system and the 1 N m/h(5 kW) PEM electrolysis system. With the proposed power controller, the AWE and PEM electrolysis system can change the stack power within 0.266s and 0.21s respectively, meeting the requirements of energy management and frequency regulation. Additionally, the temperature stability and the sensitivity of the proposed method to parameter fluctuations in the stack and DC/DC interface are analyzed.
期刊介绍:
Applied Energy serves as a platform for sharing innovations, research, development, and demonstrations in energy conversion, conservation, and sustainable energy systems. The journal covers topics such as optimal energy resource use, environmental pollutant mitigation, and energy process analysis. It welcomes original papers, review articles, technical notes, and letters to the editor. Authors are encouraged to submit manuscripts that bridge the gap between research, development, and implementation. The journal addresses a wide spectrum of topics, including fossil and renewable energy technologies, energy economics, and environmental impacts. Applied Energy also explores modeling and forecasting, conservation strategies, and the social and economic implications of energy policies, including climate change mitigation. It is complemented by the open-access journal Advances in Applied Energy.