A filter calibration method for laser-scanned weld toe geometries

IF 2.2 Q2 ENGINEERING, MULTIDISCIPLINARY Applications in engineering science Pub Date : 2024-11-06 DOI:10.1016/j.apples.2024.100200
Finn Renken , Matthias Jung , Sören Ehlers , Moritz Braun
{"title":"A filter calibration method for laser-scanned weld toe geometries","authors":"Finn Renken ,&nbsp;Matthias Jung ,&nbsp;Sören Ehlers ,&nbsp;Moritz Braun","doi":"10.1016/j.apples.2024.100200","DOIUrl":null,"url":null,"abstract":"<div><div>The scanning of weld seams can be used to evaluate the local weld toe geometry for fatigue assessments. Laser scanned weld seam profiles often contain noise which complicates the accurate measurement of the weld toe geometry. For that reason, filtering of the scanned data is necessary. The issue at hand is that a filtering method can significantly affect the measurement results. Therefore, a calibration of the filter input parameters is needed. In this study, a calibration method for filtered laser-scanned weld profiles is presented by using artificial weld toe geometries. The adjustment of different filter functions is achieved by using an optimization method on predefined weld toes with an artificial noise. The resulting input data for the filter functions is tested on a real specimen to verify the method. Through the calibration method it is possible to achieve satisfactory measurement results with precisely set input parameters for the filter functions. The most suitable filter functions for the measurement of the weld toe are the Gaussian and the Lowpass filter. Both functions are adequate as a universally applicable filter. For the evaluation of the measurement results of the radii and angles, a tolerance range is introduced, which is defined by the theoretically minimum measurable radii and angles. Using an adjusted Lowpass filter and a point distance of 0.07 mm set by the laser scanner, a measurement within the tolerance range of 0.2 mm is achievable for the weld toe radius. For the weld toe angle, the tolerance range of 1.5° is achieved for the majority of measurements.</div></div>","PeriodicalId":72251,"journal":{"name":"Applications in engineering science","volume":"20 ","pages":"Article 100200"},"PeriodicalIF":2.2000,"publicationDate":"2024-11-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applications in engineering science","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666496824000268","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

The scanning of weld seams can be used to evaluate the local weld toe geometry for fatigue assessments. Laser scanned weld seam profiles often contain noise which complicates the accurate measurement of the weld toe geometry. For that reason, filtering of the scanned data is necessary. The issue at hand is that a filtering method can significantly affect the measurement results. Therefore, a calibration of the filter input parameters is needed. In this study, a calibration method for filtered laser-scanned weld profiles is presented by using artificial weld toe geometries. The adjustment of different filter functions is achieved by using an optimization method on predefined weld toes with an artificial noise. The resulting input data for the filter functions is tested on a real specimen to verify the method. Through the calibration method it is possible to achieve satisfactory measurement results with precisely set input parameters for the filter functions. The most suitable filter functions for the measurement of the weld toe are the Gaussian and the Lowpass filter. Both functions are adequate as a universally applicable filter. For the evaluation of the measurement results of the radii and angles, a tolerance range is introduced, which is defined by the theoretically minimum measurable radii and angles. Using an adjusted Lowpass filter and a point distance of 0.07 mm set by the laser scanner, a measurement within the tolerance range of 0.2 mm is achievable for the weld toe radius. For the weld toe angle, the tolerance range of 1.5° is achieved for the majority of measurements.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
激光扫描焊趾几何形状的滤波器校准方法
焊缝扫描可用于评估局部焊趾的几何形状,以进行疲劳评估。激光扫描的焊缝轮廓通常含有噪声,这使得焊趾几何形状的精确测量变得复杂。因此,有必要对扫描数据进行过滤。目前的问题是,滤波方法会严重影响测量结果。因此,需要对滤波器输入参数进行校准。在本研究中,通过使用人工焊趾几何形状,提出了一种用于滤波激光扫描焊缝轮廓的校准方法。通过对带有人工噪声的预定义焊趾使用优化方法,实现了对不同滤波器函数的调整。滤波器函数的输入数据在真实试样上进行测试,以验证该方法。通过校准方法,可以精确设置滤波函数的输入参数,从而获得令人满意的测量结果。最适合测量焊趾的滤波器函数是高斯滤波器和低通滤波器。这两种滤波器都是通用的滤波器。为了评估半径和角度的测量结果,引入了一个公差范围,该范围由理论上可测量的最小半径和角度定义。使用调整后的低通滤波器和激光扫描仪设定的 0.07 毫米点距,可以在 0.2 毫米的公差范围内测量焊趾半径。对于焊趾角度,大部分测量都能达到 1.5° 的公差范围。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Applications in engineering science
Applications in engineering science Mechanical Engineering
CiteScore
3.60
自引率
0.00%
发文量
0
审稿时长
68 days
期刊最新文献
A filter calibration method for laser-scanned weld toe geometries Numerical simulation of open channel basaltic lava flow through topographical bends An experimental study on heat transfer using electrohydrodynamics (EHD) over a heated vertical plate. Lattice Boltzmann simulations of unsteady Bingham fluid flows Thermo-fluid performance of axially perforated multiple rectangular flow deflector-type baffle plate in an tubular heat exchanger
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1