{"title":"Investigation and insights on the on-demand generation of monodispersed emulsion droplets from a floating capillary-based open microfluidic device.","authors":"Yueming Deng, Shuting Xie, Zhengguang Li, Ruizhi Yang, Zhenping Liu, Jiyuan Yao, Haopeng Zhang, Mingliang Jin, Lingling Shui","doi":"10.1063/5.0234937","DOIUrl":null,"url":null,"abstract":"<p><p>Simple and stable generation of monodispersed droplets with volume from picolitre to nanoliter is one of the key factors in high-throughput quantitative microreactors for chemical and biomedical applications. In this work, an efficient method that could realize simple manipulating microflow with a broad operation window for preparing monodispersed droplets with controllable diameter is developed. The microfluidic device is constructed by inserting a capillary with an oblique angle (α) into the continuous phase, named a floating capillary-based open microfluidic device (FCOMD). The transition of droplet-generating mode between dripping and jetting can be achieved by changing capillary number and α. A computational model based on the volume-of-fluid/continuum-surface-force method to explain the controllability of α on the droplet formation regime and droplet breakage, verifying the synergistic effect of ΔP and Fb, facilitates the droplet pinching. A descending order of Pn of capillary with different α is that 45° > 30° > 15° > 60° > 75°, leading to the same order of generated droplet's D. When compared with the traditional capillary co-flow device, the generating throughput of the integrated FCOMD obtained by integrating different numbers of capillaries is at least ten times. Moreover, water in oil, oil in water double-emulsion, colloidal dispersed droplets, and liquid crystal droplets with diameters ranging from 25 to 800 μm are prepared on-demand by the FCOMD, indicating the universality of the microfluidic device. Thus, the FCOMD shows the features of simplicity, practicability, and flexibility, offering valuable guidance for generating controllable droplets with wide size change and showing a great potential application in material science, foods, pharmaceuticals, and cosmetics.</p>","PeriodicalId":15313,"journal":{"name":"Journal of Chemical Physics","volume":"161 19","pages":""},"PeriodicalIF":3.1000,"publicationDate":"2024-11-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Chemical Physics","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1063/5.0234937","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Simple and stable generation of monodispersed droplets with volume from picolitre to nanoliter is one of the key factors in high-throughput quantitative microreactors for chemical and biomedical applications. In this work, an efficient method that could realize simple manipulating microflow with a broad operation window for preparing monodispersed droplets with controllable diameter is developed. The microfluidic device is constructed by inserting a capillary with an oblique angle (α) into the continuous phase, named a floating capillary-based open microfluidic device (FCOMD). The transition of droplet-generating mode between dripping and jetting can be achieved by changing capillary number and α. A computational model based on the volume-of-fluid/continuum-surface-force method to explain the controllability of α on the droplet formation regime and droplet breakage, verifying the synergistic effect of ΔP and Fb, facilitates the droplet pinching. A descending order of Pn of capillary with different α is that 45° > 30° > 15° > 60° > 75°, leading to the same order of generated droplet's D. When compared with the traditional capillary co-flow device, the generating throughput of the integrated FCOMD obtained by integrating different numbers of capillaries is at least ten times. Moreover, water in oil, oil in water double-emulsion, colloidal dispersed droplets, and liquid crystal droplets with diameters ranging from 25 to 800 μm are prepared on-demand by the FCOMD, indicating the universality of the microfluidic device. Thus, the FCOMD shows the features of simplicity, practicability, and flexibility, offering valuable guidance for generating controllable droplets with wide size change and showing a great potential application in material science, foods, pharmaceuticals, and cosmetics.
期刊介绍:
The Journal of Chemical Physics publishes quantitative and rigorous science of long-lasting value in methods and applications of chemical physics. The Journal also publishes brief Communications of significant new findings, Perspectives on the latest advances in the field, and Special Topic issues. The Journal focuses on innovative research in experimental and theoretical areas of chemical physics, including spectroscopy, dynamics, kinetics, statistical mechanics, and quantum mechanics. In addition, topical areas such as polymers, soft matter, materials, surfaces/interfaces, and systems of biological relevance are of increasing importance.
Topical coverage includes:
Theoretical Methods and Algorithms
Advanced Experimental Techniques
Atoms, Molecules, and Clusters
Liquids, Glasses, and Crystals
Surfaces, Interfaces, and Materials
Polymers and Soft Matter
Biological Molecules and Networks.