{"title":"Preventing troublesome variability in clinical blood pressure measurement.","authors":"Chengyu Liu, Jian Liu, Jianqing Li, Alan Murray","doi":"10.1038/s41371-024-00978-3","DOIUrl":null,"url":null,"abstract":"<p><p>The importance of accurate blood pressure (BP) measurement is well-established. However, there is little quantitative comparative data on the influence of different measurement conditions on BP or the stability of the oscillometric pulse waveform from which BP is calculated. This study investigates the effect of six different measurement conditions (Quiet, Reading, Speaking, Deep Breathing, Moving, and Tapping) on BP readings in 30 healthy normotensive subjects. We hypothesize that non-standard conditions will result in significant deviations in BP measurements compared to the Quiet condition. Additionally, the quality and stability of the oscillometric waveform were assessed by evaluating the smoothness of the oscillometric pulse waveform characteristics during cuff deflation. Compared with the Quiet condition, all others resulted in significantly higher blood pressures, except for the respiratory condition, which resulted in significantly lower BPs. Average subject systolic BP (SBP) rose from 117.4 ± 6.0 mmHg for the Quiet condition to 129.7 ± 7.2 mmHg for the light finger tapping condition, P < 0.00001. Overall, changes for diastolic BP (DBP) were not significant. For the quality Noise indicator, all conditions in comparison with the Quiet condition were significantly noisier, increasing from 0.144 ± 0.024 to 1.055 ± 0.308 mmHg, P < 0.00001. Changes in SBP were significantly correlated to changes in quality Noise (r = 0.965, P < 0.001). This study confirms the importance of following international BP measurement guidelines, providing quantitative data showing significant changes in BP when guidelines are not followed. A method for assessing the quality of the measurement is also demonstrated, and shows that BP changes are significantly related to changes in the quality indicator.</p>","PeriodicalId":16070,"journal":{"name":"Journal of Human Hypertension","volume":" ","pages":""},"PeriodicalIF":2.7000,"publicationDate":"2024-11-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Human Hypertension","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1038/s41371-024-00978-3","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0
Abstract
The importance of accurate blood pressure (BP) measurement is well-established. However, there is little quantitative comparative data on the influence of different measurement conditions on BP or the stability of the oscillometric pulse waveform from which BP is calculated. This study investigates the effect of six different measurement conditions (Quiet, Reading, Speaking, Deep Breathing, Moving, and Tapping) on BP readings in 30 healthy normotensive subjects. We hypothesize that non-standard conditions will result in significant deviations in BP measurements compared to the Quiet condition. Additionally, the quality and stability of the oscillometric waveform were assessed by evaluating the smoothness of the oscillometric pulse waveform characteristics during cuff deflation. Compared with the Quiet condition, all others resulted in significantly higher blood pressures, except for the respiratory condition, which resulted in significantly lower BPs. Average subject systolic BP (SBP) rose from 117.4 ± 6.0 mmHg for the Quiet condition to 129.7 ± 7.2 mmHg for the light finger tapping condition, P < 0.00001. Overall, changes for diastolic BP (DBP) were not significant. For the quality Noise indicator, all conditions in comparison with the Quiet condition were significantly noisier, increasing from 0.144 ± 0.024 to 1.055 ± 0.308 mmHg, P < 0.00001. Changes in SBP were significantly correlated to changes in quality Noise (r = 0.965, P < 0.001). This study confirms the importance of following international BP measurement guidelines, providing quantitative data showing significant changes in BP when guidelines are not followed. A method for assessing the quality of the measurement is also demonstrated, and shows that BP changes are significantly related to changes in the quality indicator.
期刊介绍:
Journal of Human Hypertension is published monthly and is of interest to health care professionals who deal with hypertension (specialists, internists, primary care physicians) and public health workers. We believe that our patients benefit from robust scientific data that are based on well conducted clinical trials. We also believe that basic sciences are the foundations on which we build our knowledge of clinical conditions and their management. Towards this end, although we are primarily a clinical based journal, we also welcome suitable basic sciences studies that promote our understanding of human hypertension.
The journal aims to perform the dual role of increasing knowledge in the field of high blood pressure as well as improving the standard of care of patients. The editors will consider for publication all suitable papers dealing directly or indirectly with clinical aspects of hypertension, including but not limited to epidemiology, pathophysiology, therapeutics and basic sciences involving human subjects or tissues. We also consider papers from all specialties such as ophthalmology, cardiology, nephrology, obstetrics and stroke medicine that deal with the various aspects of hypertension and its complications.