{"title":"The properties of LGAD with different sensitive areas","authors":"Jiaying Zhou , Mengzhao Li , Yuekun Heng , Weimin Song , Weiyi Sun , Tianyuan Zhang , Mei Zhao , Zhijun Liang","doi":"10.1016/j.nima.2024.170074","DOIUrl":null,"url":null,"abstract":"<div><div>The Low Gain Avalanche Diode (LGAD) is a high-precision silicon-based timing sensor, with pixel sizes of 1.3 <span><math><mrow><mo>×</mo><mspace></mspace><mn>1</mn><mo>.</mo><mn>3</mn><mspace></mspace><msup><mrow><mtext>mm</mtext></mrow><mrow><mn>2</mn></mrow></msup></mrow></math></span> utilized in the High Granularity Timing Detector (HGTD) project at ATLAS. However, in future lepton colliders and space based experiments, the particle density is much lower than in Hadron colliders. Therefore, increasing the pixel area of the LGAD could lead to a reduction in the channel density of the readout electronics, resulting in cost and power consumption savings for experiments with low particle densities. It is essential to conduct detailed studies on the impact of area expansion on the time resolution and Signal-to-Noise Ratio (SNR) of LGAD need to be studied in detail to provide a reference for the application of large-area LGADs. Different-area sensors are obtained by connecting different numbers of pixels in parallel within the LGAD array. These LGADs are designed by the Institute of High Energy Physics (IHEP, CAS) and manufactured by the Institute of Microelectronics (IME, CAS), feature an epitaxial layer thickness of <span><math><mrow><mn>50</mn><mspace></mspace><mi>μ</mi><mi>m</mi></mrow></math></span>. This paper studies the breakdown voltage, leakage current, and depletion process of devices with different areas, while also examining the time resolution, SNR, rise time and other parameters of sensors with varying areas using a beta source (<span><math><mrow><msup><mrow></mrow><mrow><mn>90</mn></mrow></msup><mi>Sr</mi></mrow></math></span>) test system. The test results indicate that as the area of devices increases from 1.69 <span><math><msup><mrow><mtext>mm</mtext></mrow><mrow><mn>2</mn></mrow></msup></math></span> to 42.25 <span><math><msup><mrow><mtext>mm</mtext></mrow><mrow><mn>2</mn></mrow></msup></math></span>, the time resolution deteriorates significantly from 37 ps to 65 ps. The depletion capacitance of the device increases with the area, resulting in a slower <span><math><mrow><mi>R</mi><mi>C</mi></mrow></math></span> process for signal formation, longer signal rise time, and decreased SNR ratio, leading to a deterioration of time resolution.</div></div>","PeriodicalId":19359,"journal":{"name":"Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment","volume":"1071 ","pages":"Article 170074"},"PeriodicalIF":1.5000,"publicationDate":"2024-11-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment","FirstCategoryId":"101","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0168900224010003","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0
Abstract
The Low Gain Avalanche Diode (LGAD) is a high-precision silicon-based timing sensor, with pixel sizes of 1.3 utilized in the High Granularity Timing Detector (HGTD) project at ATLAS. However, in future lepton colliders and space based experiments, the particle density is much lower than in Hadron colliders. Therefore, increasing the pixel area of the LGAD could lead to a reduction in the channel density of the readout electronics, resulting in cost and power consumption savings for experiments with low particle densities. It is essential to conduct detailed studies on the impact of area expansion on the time resolution and Signal-to-Noise Ratio (SNR) of LGAD need to be studied in detail to provide a reference for the application of large-area LGADs. Different-area sensors are obtained by connecting different numbers of pixels in parallel within the LGAD array. These LGADs are designed by the Institute of High Energy Physics (IHEP, CAS) and manufactured by the Institute of Microelectronics (IME, CAS), feature an epitaxial layer thickness of . This paper studies the breakdown voltage, leakage current, and depletion process of devices with different areas, while also examining the time resolution, SNR, rise time and other parameters of sensors with varying areas using a beta source () test system. The test results indicate that as the area of devices increases from 1.69 to 42.25 , the time resolution deteriorates significantly from 37 ps to 65 ps. The depletion capacitance of the device increases with the area, resulting in a slower process for signal formation, longer signal rise time, and decreased SNR ratio, leading to a deterioration of time resolution.
期刊介绍:
Section A of Nuclear Instruments and Methods in Physics Research publishes papers on design, manufacturing and performance of scientific instruments with an emphasis on large scale facilities. This includes the development of particle accelerators, ion sources, beam transport systems and target arrangements as well as the use of secondary phenomena such as synchrotron radiation and free electron lasers. It also includes all types of instrumentation for the detection and spectrometry of radiations from high energy processes and nuclear decays, as well as instrumentation for experiments at nuclear reactors. Specialized electronics for nuclear and other types of spectrometry as well as computerization of measurements and control systems in this area also find their place in the A section.
Theoretical as well as experimental papers are accepted.