{"title":"Radiation protection and personal dosimetry in a core facility for multimodal small animal imaging.","authors":"Anna Schildt, Peter Sänger, Matthias Lütgens, Stefan Polei, Chris Lappe, Markus Joksch, Bernd Joachim Krause, Brigitte Vollmar, Marc-André Weber, Tobias Lindner","doi":"10.1055/a-2462-2419","DOIUrl":null,"url":null,"abstract":"<p><p>Clinical imaging techniques such as positron emission tomography (PET) in combination with computed tomography (CT) are increasingly being used in biomedical research involving small animal models. The handling of open radioactive substances (radiopharmaceuticals) necessary for PET imaging requires prior official authorization for handling, the application of radiation protection principles, and regular training. The overriding aim of radiation protection is to protect the personnel directly involved, other persons, and the environment from the harmful effects of ionizing radiation.This paper aims to provide an overview of the regulatory requirements of the Radiation Protection Act (StrlSchG), the Radiation Protection Ordinance (StrlSchV), and the associated standards and guidelines. Furthermore, their implementation in practical work in small animal imaging using PET/CT is shown. We will focus on the individual steps of the imaging process, from delivery of the radiopharmaceuticals to waste disposal. This should provide interested researchers with an initial overview of the safe and successful use of the method. In addition, exposure values from the last six years in the literature were analyzed. While personal dosimetric monitoring in clinical PET/CT imaging has been extensively published, there is no published data known to us for personnel for PET/CT research with small animals. The evaluation of the personal dosimetric monitoring of our small animal imaging facility with 7 employees over 4 years revealed an increased personal and finger dose normalized to the injected activity and compared to human PET/CT imaging. Nevertheless, the annual personal dose or annual finger dose in small animal imaging (Hp(10): 1.7 mSv, Hp(0.07): 64 mSv) is lower than for personnel performing human PET/CT imaging at the local University Department of Nuclear Medicine (Hp(10): 3.8 mSv, Hp(0.07): 156 mSv) or published values, and is well below the legally permissible maximum dose of 20 or 500 mSv per year.The increasing use of PET/CT in small animal research can be safely utilized if the radiation protection principles are implemented and continuously trained. · PET/CT imaging in small animals is increasingly used in biomedical research.. · Radiation protection laws and guidelines have to be known and are relevant in animal experiments.. · Compared to published values from human medicine, activity-specific employee doses are increased in the presented imaging facility.. · The legal personal dose in the studied imaging facility is below legal limits.. · Schildt A, Sänger P, Lütgens M et al. Radiation protection and personal dosimetry in a core facility for multimodal small animal imaging. Fortschr Röntgenstr 2024; DOI 10.1055/a-2462-2419.</p>","PeriodicalId":21490,"journal":{"name":"Rofo-fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren","volume":" ","pages":""},"PeriodicalIF":1.3000,"publicationDate":"2024-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Rofo-fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1055/a-2462-2419","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Clinical imaging techniques such as positron emission tomography (PET) in combination with computed tomography (CT) are increasingly being used in biomedical research involving small animal models. The handling of open radioactive substances (radiopharmaceuticals) necessary for PET imaging requires prior official authorization for handling, the application of radiation protection principles, and regular training. The overriding aim of radiation protection is to protect the personnel directly involved, other persons, and the environment from the harmful effects of ionizing radiation.This paper aims to provide an overview of the regulatory requirements of the Radiation Protection Act (StrlSchG), the Radiation Protection Ordinance (StrlSchV), and the associated standards and guidelines. Furthermore, their implementation in practical work in small animal imaging using PET/CT is shown. We will focus on the individual steps of the imaging process, from delivery of the radiopharmaceuticals to waste disposal. This should provide interested researchers with an initial overview of the safe and successful use of the method. In addition, exposure values from the last six years in the literature were analyzed. While personal dosimetric monitoring in clinical PET/CT imaging has been extensively published, there is no published data known to us for personnel for PET/CT research with small animals. The evaluation of the personal dosimetric monitoring of our small animal imaging facility with 7 employees over 4 years revealed an increased personal and finger dose normalized to the injected activity and compared to human PET/CT imaging. Nevertheless, the annual personal dose or annual finger dose in small animal imaging (Hp(10): 1.7 mSv, Hp(0.07): 64 mSv) is lower than for personnel performing human PET/CT imaging at the local University Department of Nuclear Medicine (Hp(10): 3.8 mSv, Hp(0.07): 156 mSv) or published values, and is well below the legally permissible maximum dose of 20 or 500 mSv per year.The increasing use of PET/CT in small animal research can be safely utilized if the radiation protection principles are implemented and continuously trained. · PET/CT imaging in small animals is increasingly used in biomedical research.. · Radiation protection laws and guidelines have to be known and are relevant in animal experiments.. · Compared to published values from human medicine, activity-specific employee doses are increased in the presented imaging facility.. · The legal personal dose in the studied imaging facility is below legal limits.. · Schildt A, Sänger P, Lütgens M et al. Radiation protection and personal dosimetry in a core facility for multimodal small animal imaging. Fortschr Röntgenstr 2024; DOI 10.1055/a-2462-2419.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.20
自引率
5.60%
发文量
340
期刊介绍: Die RöFo veröffentlicht Originalarbeiten, Übersichtsartikel und Fallberichte aus dem Bereich der Radiologie und den weiteren bildgebenden Verfahren in der Medizin. Es dürfen nur Arbeiten eingereicht werden, die noch nicht veröffentlicht sind und die auch nicht gleichzeitig einer anderen Zeitschrift zur Veröffentlichung angeboten wurden. Alle eingereichten Beiträge unterliegen einer sorgfältigen fachlichen Begutachtung. Gegründet 1896 – nur knapp 1 Jahr nach der Entdeckung der Röntgenstrahlen durch C.W. Röntgen – blickt die RöFo auf über 100 Jahre Erfahrung als wichtigstes Publikationsmedium in der deutschsprachigen Radiologie zurück. Sie ist damit die älteste radiologische Fachzeitschrift und schafft es erfolgreich, lange Kontinuität mit dem Anspruch an wissenschaftliches Publizieren auf internationalem Niveau zu verbinden. Durch ihren zentralen Platz im Verlagsprogramm stellte die RöFo die Basis für das heute umfassende und erfolgreiche Radiologie-Medienangebot im Georg Thieme Verlag. Besonders eng verbunden ist die RöFo mit der Geschichte der Röntgengesellschaften in Deutschland und Österreich. Sie ist offizielles Organ von DRG und ÖRG und die Mitglieder der Fachgesellschaften erhalten die Zeitschrift im Rahmen ihrer Mitgliedschaft. Mit ihrem wissenschaftlichen Kernteil und dem eigenen Mitteilungsteil der Fachgesellschaften bietet die RöFo Monat für Monat ein Forum für den Austausch von Inhalten und Botschaften der radiologischen Community im deutschsprachigen Raum.
期刊最新文献
FHIR - Overdue Standard for Radiology Data Warehouses. Prenatal imaging - role of fetal MRI. Exploring gender roles in German interventional radiology - how progressive are we? Parapharyngeal Space: Diagnostic Imaging and Intervention. Radiation protection and personal dosimetry in a core facility for multimodal small animal imaging.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1