The anesthetic and recovery profiles of low-dose hypobaric mepivacaine and bupivacaine for spinal anesthesia in total hip and knee arthroplasty: a prospective observational study.
Joanne M H Tan, Wendy Wang, Takayuki Yoshida, Sara Abdullah, Jayanta Chowdhury, Ki Jinn Chin
{"title":"The anesthetic and recovery profiles of low-dose hypobaric mepivacaine and bupivacaine for spinal anesthesia in total hip and knee arthroplasty: a prospective observational study.","authors":"Joanne M H Tan, Wendy Wang, Takayuki Yoshida, Sara Abdullah, Jayanta Chowdhury, Ki Jinn Chin","doi":"10.1007/s12630-024-02887-y","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Same-day mobilization and early hospital discharge is increasingly emphasized following hip and knee arthroplasty. One challenge of spinal anesthesia in this setting is achieving adequate block height while avoiding excessively large local anesthetic doses and prolonged motor and sensory blockade. Using a hypobaric local anesthetic solution is one potential strategy, as its intrathecal distribution can be reliably manipulated by patient positioning to achieve adequate block height independent of dose.</p><p><strong>Methods: </strong>We conducted a prospective observational study to determine the clinical characteristics of spinal anesthesia with low-dose hypobaric mepivacaine and bupivacaine in patients undergoing hip and knee arthroplasty. Thirty patients scheduled for same-day discharge received 51 mg of hypobaric 1.5% mepivacaine and 30 patients scheduled for inpatient stay received 10 mg of hypobaric 0.33% bupivacaine.</p><p><strong>Results: </strong>The mean (standard deviation) time to achieve sensory blockade at or above L1 and T10 in the operative limb was 5.7 (1.8) and 7.3 (3.3) min with mepivacaine and 6.2 (2.6) and 8.1 (4.8) min with bupivacaine, respectively. Anesthesia was adequate for surgical commencement in all patients regardless of spinal injection level. Four patients required anesthetic supplementation for surgical completion. Sensory block duration at or above T10 and L1 in the operative limb was 97 (27) and 115 (37) min with mepivacaine and 127 (32) and 161 (34) min with bupivacaine, respectively. Motor function returned by 145 (37) and 217 (43) min in mepivacaine and bupivacaine groups, respectively.</p><p><strong>Conclusion: </strong>The anesthetic profiles of low-dose hypobaric mepivacaine and bupivacaine were favorable for fast-track hip and knee arthroplasty with short and predictable operating times.</p>","PeriodicalId":56145,"journal":{"name":"Canadian Journal of Anesthesia-Journal Canadien D Anesthesie","volume":" ","pages":""},"PeriodicalIF":3.4000,"publicationDate":"2024-12-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Canadian Journal of Anesthesia-Journal Canadien D Anesthesie","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s12630-024-02887-y","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: Same-day mobilization and early hospital discharge is increasingly emphasized following hip and knee arthroplasty. One challenge of spinal anesthesia in this setting is achieving adequate block height while avoiding excessively large local anesthetic doses and prolonged motor and sensory blockade. Using a hypobaric local anesthetic solution is one potential strategy, as its intrathecal distribution can be reliably manipulated by patient positioning to achieve adequate block height independent of dose.
Methods: We conducted a prospective observational study to determine the clinical characteristics of spinal anesthesia with low-dose hypobaric mepivacaine and bupivacaine in patients undergoing hip and knee arthroplasty. Thirty patients scheduled for same-day discharge received 51 mg of hypobaric 1.5% mepivacaine and 30 patients scheduled for inpatient stay received 10 mg of hypobaric 0.33% bupivacaine.
Results: The mean (standard deviation) time to achieve sensory blockade at or above L1 and T10 in the operative limb was 5.7 (1.8) and 7.3 (3.3) min with mepivacaine and 6.2 (2.6) and 8.1 (4.8) min with bupivacaine, respectively. Anesthesia was adequate for surgical commencement in all patients regardless of spinal injection level. Four patients required anesthetic supplementation for surgical completion. Sensory block duration at or above T10 and L1 in the operative limb was 97 (27) and 115 (37) min with mepivacaine and 127 (32) and 161 (34) min with bupivacaine, respectively. Motor function returned by 145 (37) and 217 (43) min in mepivacaine and bupivacaine groups, respectively.
Conclusion: The anesthetic profiles of low-dose hypobaric mepivacaine and bupivacaine were favorable for fast-track hip and knee arthroplasty with short and predictable operating times.
期刊介绍:
The Canadian Journal of Anesthesia (the Journal) is owned by the Canadian Anesthesiologists’
Society and is published by Springer Science + Business Media, LLM (New York). From the
first year of publication in 1954, the international exposure of the Journal has broadened
considerably, with articles now received from over 50 countries. The Journal is published
monthly, and has an impact Factor (mean journal citation frequency) of 2.127 (in 2012). Article
types consist of invited editorials, reports of original investigations (clinical and basic sciences
articles), case reports/case series, review articles, systematic reviews, accredited continuing
professional development (CPD) modules, and Letters to the Editor. The editorial content,
according to the mission statement, spans the fields of anesthesia, acute and chronic pain,
perioperative medicine and critical care. In addition, the Journal publishes practice guidelines
and standards articles relevant to clinicians. Articles are published either in English or in French,
according to the language of submission.