Assessing the feasibility of handheld scanning technologies in neonatal intensive care: Trueness, acceptability, and suitability for personalised medical devices.

IF 2.6 3区 医学 Q2 CRITICAL CARE MEDICINE Australian Critical Care Pub Date : 2024-12-10 DOI:10.1016/j.aucc.2024.09.012
Deanne August, Isabel Byram, David Forrestal, Mathilde Desselle, Nathan Stevenson, Kartik Iyer, Mark W Davies, Katherine White, Linda Cobbald, Lynette Chapple, Kellie McGrory, Margaret McLean, Stephanie Hall, Brittany Schoenmaker, Jackie Clement, Melissa M Lai
{"title":"Assessing the feasibility of handheld scanning technologies in neonatal intensive care: Trueness, acceptability, and suitability for personalised medical devices.","authors":"Deanne August, Isabel Byram, David Forrestal, Mathilde Desselle, Nathan Stevenson, Kartik Iyer, Mark W Davies, Katherine White, Linda Cobbald, Lynette Chapple, Kellie McGrory, Margaret McLean, Stephanie Hall, Brittany Schoenmaker, Jackie Clement, Melissa M Lai","doi":"10.1016/j.aucc.2024.09.012","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Nasal continuous positive airway pressure (CPAP) injuries are common for premature infants. Clinical use of three-dimensional (3D) scanning is established in adult medicine, but the possibilities in neonatal care are still emerging. Custom printed CPAP devices have the potential to reduce injuries and disfigurement in this vulnerable population.</p><p><strong>Aim: </strong>We sought to identify the most feasible portable 3D scanner for use in the neonatal intensive care environment towards the development of custom-fitting CPAP devices for premature infants.</p><p><strong>Methods: </strong>Four handheld 3D scanners were assessed and compared, Artec Leo, Revopoint POP 2, iPad Pro/Metascan, and iPhone/Scandy Pro. Trained neonatal clinicians (medical and nursing) undertook mock scans in a simulated neonatal intensive care environment.</p><p><strong>Results: </strong>Sixty scans were performed by 13 neonatal clinicians (four medical/nurse practitioners and nine nurses). The median mean absolute error was 0.21 mm (interquartile range [IQR]: 0.19-0.26), 0.17 mm (IQR: 0.15-0.21), and 1.08 mm (IQR: 1.0-1.63) for Artec Leo, Revopoint POP 2, and Scandy Pro, respectively. Scan times were the quickest for Artec Leo at 22.9 sec (IQR: 18.5-27), followed by Revopoint POP 2 at 25.2 sec (IQR: 22-34.4). Artec Leo was rated most expensive, but Revopoint POP 2 was rated more ergonomic. Both app-based 3D scanners (Metascan and Scandy Pro) presented data security issues.</p><p><strong>Conclusions: </strong>Artec Leo and Revopoint POP 2 were identified as most feasible for use to perform 3D scans on premature infants in the neonatal intensive care environment.</p>","PeriodicalId":51239,"journal":{"name":"Australian Critical Care","volume":" ","pages":"101127"},"PeriodicalIF":2.6000,"publicationDate":"2024-12-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Australian Critical Care","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.aucc.2024.09.012","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CRITICAL CARE MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Nasal continuous positive airway pressure (CPAP) injuries are common for premature infants. Clinical use of three-dimensional (3D) scanning is established in adult medicine, but the possibilities in neonatal care are still emerging. Custom printed CPAP devices have the potential to reduce injuries and disfigurement in this vulnerable population.

Aim: We sought to identify the most feasible portable 3D scanner for use in the neonatal intensive care environment towards the development of custom-fitting CPAP devices for premature infants.

Methods: Four handheld 3D scanners were assessed and compared, Artec Leo, Revopoint POP 2, iPad Pro/Metascan, and iPhone/Scandy Pro. Trained neonatal clinicians (medical and nursing) undertook mock scans in a simulated neonatal intensive care environment.

Results: Sixty scans were performed by 13 neonatal clinicians (four medical/nurse practitioners and nine nurses). The median mean absolute error was 0.21 mm (interquartile range [IQR]: 0.19-0.26), 0.17 mm (IQR: 0.15-0.21), and 1.08 mm (IQR: 1.0-1.63) for Artec Leo, Revopoint POP 2, and Scandy Pro, respectively. Scan times were the quickest for Artec Leo at 22.9 sec (IQR: 18.5-27), followed by Revopoint POP 2 at 25.2 sec (IQR: 22-34.4). Artec Leo was rated most expensive, but Revopoint POP 2 was rated more ergonomic. Both app-based 3D scanners (Metascan and Scandy Pro) presented data security issues.

Conclusions: Artec Leo and Revopoint POP 2 were identified as most feasible for use to perform 3D scans on premature infants in the neonatal intensive care environment.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Australian Critical Care
Australian Critical Care NURSING-NURSING
CiteScore
4.90
自引率
9.10%
发文量
148
审稿时长
>12 weeks
期刊介绍: Australian Critical Care is the official journal of the Australian College of Critical Care Nurses (ACCCN). It is a bi-monthly peer-reviewed journal, providing clinically relevant research, reviews and articles of interest to the critical care community. Australian Critical Care publishes peer-reviewed scholarly papers that report research findings, research-based reviews, discussion papers and commentaries which are of interest to an international readership of critical care practitioners, educators, administrators and researchers. Interprofessional articles are welcomed.
期刊最新文献
Expression of Concern: Comparison of different eye care methods to prevent dry eye and corneal ulcer in older critically ill patients: A randomised controlled trial. A systematic review of the comparative effects of sound and music interventions for intensive care unit patients' outcomes. An interprofessional multicomponent intervention to improve end-of-life care in intensive care: A before-and-after study. Editorial draft Volume 38, Issue 1, 2025. The clinical utility of shock index in hospitalised patients requiring activation of the rapid response team.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1