Effectiveness and safety of a thermo-mechanical action device versus thermal pulsation device in the treatment of meibomian gland dysfunction.

IF 2.6 3区 医学 Q2 OPHTHALMOLOGY Journal of cataract and refractive surgery Pub Date : 2024-12-16 DOI:10.1097/j.jcrs.0000000000001602
Ehsan Sadri, Anthony Verachtert, Gregory D Parkhurst, Julio Echegoyen, Ifat Klein, Yael G Agmon, Gregg J Berdy
{"title":"Effectiveness and safety of a thermo-mechanical action device versus thermal pulsation device in the treatment of meibomian gland dysfunction.","authors":"Ehsan Sadri, Anthony Verachtert, Gregory D Parkhurst, Julio Echegoyen, Ifat Klein, Yael G Agmon, Gregg J Berdy","doi":"10.1097/j.jcrs.0000000000001602","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the safety and effectiveness of thermo-mechanical action (Tixel C, Novoxel) compared with thermal pulsation (LipiFlow, Johnson & Johnson) in meibomian gland dysfunction (MGD).</p><p><strong>Setting: </strong>Private clinics and University clinic, USA.</p><p><strong>Design: </strong>Prospective, randomized (1:1), evaluator-masked, multicenter study.</p><p><strong>Methods: </strong>Subjects with Ocular Surface Disease Index (OSDI) between 23 and 79, fluorescein tear break-up time (TBUT) <10 s and Meibomian Gland Score (MGS) ≤12 in each eye received bilateral thermo-mechanical action (TMA) or thermal pulsation (TP). The treatment consisted of three sessions, two weeks apart, for TMA and one session for TP. TBUT, OSDI, MGS, and corneal and conjunctival staining (CCS) were assessed at baseline and at Weeks 4 and 12 post-last treatment session. The primary effectiveness endpoint was change in TBUT at Week 4.</p><p><strong>Results: </strong>Among the 106 treated subjects (N=53 per group), TBUT improved significantly (p<0.001) by 3.0±3.2 and 3.1±4.3 seconds after TMA and 2.7±2.7 and 3.3±3.6 seconds after TP, at Week 4 and Week 12, respectively. The change in TBUT for TMA was non-inferior to TP (linear mixed-effects model, p<0.001). OSDI, MGS and CCS significantly improved from baseline (p<0.001), with no significant between-group differences (p>0.05). OSDI improved by 26.4±21.1 and 28.6±22.4 after TMA and 18.8±21.0 and 21.9±18.5 after TP, at Week 4 and Week 12, respectively. No device-related adverse event occurred in either group.</p><p><strong>Conclusion: </strong>TMA safely and effectively improved clinical signs and symptoms of evaporative dry eye disease associated with MGD over a 12-week period, comparable to TP.</p>","PeriodicalId":15214,"journal":{"name":"Journal of cataract and refractive surgery","volume":" ","pages":""},"PeriodicalIF":2.6000,"publicationDate":"2024-12-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of cataract and refractive surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/j.jcrs.0000000000001602","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To evaluate the safety and effectiveness of thermo-mechanical action (Tixel C, Novoxel) compared with thermal pulsation (LipiFlow, Johnson & Johnson) in meibomian gland dysfunction (MGD).

Setting: Private clinics and University clinic, USA.

Design: Prospective, randomized (1:1), evaluator-masked, multicenter study.

Methods: Subjects with Ocular Surface Disease Index (OSDI) between 23 and 79, fluorescein tear break-up time (TBUT) <10 s and Meibomian Gland Score (MGS) ≤12 in each eye received bilateral thermo-mechanical action (TMA) or thermal pulsation (TP). The treatment consisted of three sessions, two weeks apart, for TMA and one session for TP. TBUT, OSDI, MGS, and corneal and conjunctival staining (CCS) were assessed at baseline and at Weeks 4 and 12 post-last treatment session. The primary effectiveness endpoint was change in TBUT at Week 4.

Results: Among the 106 treated subjects (N=53 per group), TBUT improved significantly (p<0.001) by 3.0±3.2 and 3.1±4.3 seconds after TMA and 2.7±2.7 and 3.3±3.6 seconds after TP, at Week 4 and Week 12, respectively. The change in TBUT for TMA was non-inferior to TP (linear mixed-effects model, p<0.001). OSDI, MGS and CCS significantly improved from baseline (p<0.001), with no significant between-group differences (p>0.05). OSDI improved by 26.4±21.1 and 28.6±22.4 after TMA and 18.8±21.0 and 21.9±18.5 after TP, at Week 4 and Week 12, respectively. No device-related adverse event occurred in either group.

Conclusion: TMA safely and effectively improved clinical signs and symptoms of evaporative dry eye disease associated with MGD over a 12-week period, comparable to TP.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
5.60
自引率
14.30%
发文量
259
审稿时长
8.5 weeks
期刊介绍: The Journal of Cataract & Refractive Surgery (JCRS), a preeminent peer-reviewed monthly ophthalmology publication, is the official journal of the American Society of Cataract and Refractive Surgery (ASCRS) and the European Society of Cataract and Refractive Surgeons (ESCRS). JCRS publishes high quality articles on all aspects of anterior segment surgery. In addition to original clinical studies, the journal features a consultation section, practical techniques, important cases, and reviews as well as basic science articles.
期刊最新文献
Digital vs manual axis marking for toric phakic intraocular lens alignment: prospective randomized intraindividual trial. Myopic shift after primary intraocular lens implantation in unilateral cataract children and its association with preoperative ocular parameters. Using first-eye early vault to determine implantable collamer lens size for the second eye: retrospective analysis of bilateral phakic intraocular lens implantation. Prediction of vaults in eyes with vertical implantable collamer lens implantation. Rotational stability of plate-haptic toric intraocular lenses implantation with a capsular tension ring: prospective randomized paired-eye study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1