Concentric Ring Trajectory Sampling With k-Space Reordering Enables Assessment of Tissue-Specific T1 and T2 Relaxation for 2H-Labeled Substrates in the Human Brain at 7 T.

IF 2.7 4区 医学 Q2 BIOPHYSICS NMR in Biomedicine Pub Date : 2025-02-01 DOI:10.1002/nbm.5311
Viola Bader, Bernhard Strasser, Wolfgang Bogner, Lukas Hingerl, Sabina Frese, Anna Duguid, Aaron Osburg, William T Clarke, Stanislav Motyka, Martin Krssak, Siegfried Trattnig, Thomas Scherer, Rupert Lanzenberger, Fabian Niess
{"title":"Concentric Ring Trajectory Sampling With k-Space Reordering Enables Assessment of Tissue-Specific T<sub>1</sub> and T<sub>2</sub> Relaxation for <sup>2</sup>H-Labeled Substrates in the Human Brain at 7 T.","authors":"Viola Bader, Bernhard Strasser, Wolfgang Bogner, Lukas Hingerl, Sabina Frese, Anna Duguid, Aaron Osburg, William T Clarke, Stanislav Motyka, Martin Krssak, Siegfried Trattnig, Thomas Scherer, Rupert Lanzenberger, Fabian Niess","doi":"10.1002/nbm.5311","DOIUrl":null,"url":null,"abstract":"<p><p>Deuterium metabolic imaging (DMI) is an emerging Magnetic Resonance technique providing valuable insight into the dynamics of cellular glucose (Glc) metabolism of the human brain in vivo using deuterium-labeled (<sup>2</sup>H) glucose as non-invasive tracer. Reliable concentration estimation of <sup>2</sup>H-Glc and downstream synthesized neurotransmitters glutamate + glutamine (Glx) requires accurate knowledge of relaxation times, but so far tissue-specific T<sub>1</sub> and T<sub>2</sub> relaxation times (e.g., in gray and white matter) have not been determined. Such measurements are time-consuming and particularly challenging in the presence of dynamically changing metabolite levels (e.g. <sup>2</sup>H Glc and <sup>2</sup>H Glx). This study aimed to assess T<sub>1</sub> and T<sub>2</sub> relaxation times of deuterated resonances, i.e., water, Glc and Glx in human gray and white matter using inversion recovery and Hahn spin-echo <sup>2</sup>H MRSI (magnetic resonance spectroscopic imaging), respectively, with non-Cartesian concentric ring trajectory readout (CRT) including specific k-space reordering at 7 T. The sequence was validated using phantom measurements and all results were compared to unlocalized acquisitions. Thirteen healthy volunteers participated in the study, with 10 of them scanned ~90 min after oral administration of 0.8 g/kg [6,6'-<sup>2</sup>H]-glucose. Significantly different T<sub>1</sub> and T<sub>2</sub> relaxation was observed between GM and WM for <sup>2</sup>H water (T<sub>1</sub> <sup>GM/WM/unlocalized</sup> = 358 ± 21/328 ± 12/335 m ± 6 ms, p = 0.01) and <sup>2</sup>H Glx (T<sub>2</sub> <sup>GM/WM/unlocalized</sup> = 37 ± 2/35 ± 2/33 ± 3 ms, p = 0.02), respectively, consistent with unlocalized acquisitions. No significant regional differences were found for <sup>2</sup>H water (T<sub>2</sub> <sup>GM/WM/unlocalized</sup> = 36 ± 2/34 ± 2/31 ± 2 ms, p = 0.08), <sup>2</sup>H Glc (T<sub>1</sub> <sup>GM/WM/unlocalized</sup> = 70 ± 5/73 ± 4/80 ± 5 ms, p = 0.13; T<sub>2</sub> <sup>GM/WM/unlocalized</sup> = 36 ± 1/34 ± 2/34 ± 2 ms, p = 0.24) and Glx (T<sub>1</sub> <sup>GM/WM/unlocalized</sup> = 172 ± 15/172 ± 12/165 ± 11 ms, p = 1.00). Knowledge of tissue-specific relaxation times can enhance the accuracy of concentration estimation and metabolic flux rates in future studies, potentially improving our understanding of various brain diseases such as cancer, neurodegenerative diseases or diabetes, which are often linked to impaired glucose metabolism.</p>","PeriodicalId":19309,"journal":{"name":"NMR in Biomedicine","volume":"38 2","pages":"e5311"},"PeriodicalIF":2.7000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11659634/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"NMR in Biomedicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/nbm.5311","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0

Abstract

Deuterium metabolic imaging (DMI) is an emerging Magnetic Resonance technique providing valuable insight into the dynamics of cellular glucose (Glc) metabolism of the human brain in vivo using deuterium-labeled (2H) glucose as non-invasive tracer. Reliable concentration estimation of 2H-Glc and downstream synthesized neurotransmitters glutamate + glutamine (Glx) requires accurate knowledge of relaxation times, but so far tissue-specific T1 and T2 relaxation times (e.g., in gray and white matter) have not been determined. Such measurements are time-consuming and particularly challenging in the presence of dynamically changing metabolite levels (e.g. 2H Glc and 2H Glx). This study aimed to assess T1 and T2 relaxation times of deuterated resonances, i.e., water, Glc and Glx in human gray and white matter using inversion recovery and Hahn spin-echo 2H MRSI (magnetic resonance spectroscopic imaging), respectively, with non-Cartesian concentric ring trajectory readout (CRT) including specific k-space reordering at 7 T. The sequence was validated using phantom measurements and all results were compared to unlocalized acquisitions. Thirteen healthy volunteers participated in the study, with 10 of them scanned ~90 min after oral administration of 0.8 g/kg [6,6'-2H]-glucose. Significantly different T1 and T2 relaxation was observed between GM and WM for 2H water (T1 GM/WM/unlocalized = 358 ± 21/328 ± 12/335 m ± 6 ms, p = 0.01) and 2H Glx (T2 GM/WM/unlocalized = 37 ± 2/35 ± 2/33 ± 3 ms, p = 0.02), respectively, consistent with unlocalized acquisitions. No significant regional differences were found for 2H water (T2 GM/WM/unlocalized = 36 ± 2/34 ± 2/31 ± 2 ms, p = 0.08), 2H Glc (T1 GM/WM/unlocalized = 70 ± 5/73 ± 4/80 ± 5 ms, p = 0.13; T2 GM/WM/unlocalized = 36 ± 1/34 ± 2/34 ± 2 ms, p = 0.24) and Glx (T1 GM/WM/unlocalized = 172 ± 15/172 ± 12/165 ± 11 ms, p = 1.00). Knowledge of tissue-specific relaxation times can enhance the accuracy of concentration estimation and metabolic flux rates in future studies, potentially improving our understanding of various brain diseases such as cancer, neurodegenerative diseases or diabetes, which are often linked to impaired glucose metabolism.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
同心环轨迹采样与 k 空间重排可在 7 T 条件下评估人脑中 2H 标记基质的组织特异性 T1 和 T2 弛豫。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
NMR in Biomedicine
NMR in Biomedicine 医学-光谱学
CiteScore
6.00
自引率
10.30%
发文量
209
审稿时长
3-8 weeks
期刊介绍: NMR in Biomedicine is a journal devoted to the publication of original full-length papers, rapid communications and review articles describing the development of magnetic resonance spectroscopy or imaging methods or their use to investigate physiological, biochemical, biophysical or medical problems. Topics for submitted papers should be in one of the following general categories: (a) development of methods and instrumentation for MR of biological systems; (b) studies of normal or diseased organs, tissues or cells; (c) diagnosis or treatment of disease. Reports may cover work on patients or healthy human subjects, in vivo animal experiments, studies of isolated organs or cultured cells, analysis of tissue extracts, NMR theory, experimental techniques, or instrumentation.
期刊最新文献
Concentric Ring Trajectory Sampling With k-Space Reordering Enables Assessment of Tissue-Specific T1 and T2 Relaxation for 2H-Labeled Substrates in the Human Brain at 7 T. Fast High-Resolution Metabolite Mapping in the rat Brain Using 1H-FID-MRSI at 14.1 T. Automated White Matter Fiber Tract Segmentation for the Brainstem. Altered Nigral Amide Proton Transfer Imaging Signal Concordant With Motor Asymmetry in Parkinson's Disease: A Multipool CEST MRI Study. Evaluation of the Glymphatic System in Rabbits Using Gadobutrol-Enhanced MR Cisternography With T1 and T2 Mapping.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1