Breath Analyzer for Real-Time Exercise Fat Burning Prediction: Oral and Alveolar Breath Insights with CNN

IF 9.1 1区 化学 Q1 CHEMISTRY, ANALYTICAL ACS Sensors Pub Date : 2024-12-23 DOI:10.1021/acssensors.4c02502
Byeongju Lee, Junyeong Lee, Hyung-Kun Lee, HyungJu Park, Myung-Joon Kwack, Do Yeob Kim, Inkyu Park, Soo Lim, Dae-Sik Lee
{"title":"Breath Analyzer for Real-Time Exercise Fat Burning Prediction: Oral and Alveolar Breath Insights with CNN","authors":"Byeongju Lee, Junyeong Lee, Hyung-Kun Lee, HyungJu Park, Myung-Joon Kwack, Do Yeob Kim, Inkyu Park, Soo Lim, Dae-Sik Lee","doi":"10.1021/acssensors.4c02502","DOIUrl":null,"url":null,"abstract":"The increasing prevalence of obesity and metabolic disorders has created a significant demand for personalized devices that can effectively monitor fat metabolism. In this study, we developed an advanced breath analyzer system designed to provide real-time monitoring of exercise-induced fat burning by analyzing volatile organic compounds (VOCs) present in both oral and alveolar breath. Acetone in exhaled breath and β-hydroxybutyric acid (BOHB) in the blood are both biomarkers closely linked to the metabolic fat burning process occurring in the liver, particularly after exercise. The breath analyzer utilizes a sensor array to detect VOC patterns, with the data analyzed using a one-dimensional convolutional neural network (1D CNN) for an accurate prediction of BOHB levels in the blood. We collected and analyzed 30 exhaled breath samples with our analyzer and blood samples for BOHB from participants before and after exercise. The results showed a strong correlation between sensor responses and BOHB levels, with Pearson correlation coefficients of 0.99 across different postexercise time points. The 1D CNN model effectively estimated BOHB concentrations, achieving Pearson coefficients of 0.96 for the training data set and 0.86 for the test data set. Additionally, our findings confirm that alveolar air samples, which contain metabolic byproducts from deeper in the lungs, offer more reliable data for fat burning analysis than oral air samples. This noninvasive, real-time breath monitoring tool offers a promising solution for individuals demanding to optimize their exercise routines and track metabolic health with high precision and accuracy.","PeriodicalId":24,"journal":{"name":"ACS Sensors","volume":"16 1","pages":""},"PeriodicalIF":9.1000,"publicationDate":"2024-12-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Sensors","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1021/acssensors.4c02502","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The increasing prevalence of obesity and metabolic disorders has created a significant demand for personalized devices that can effectively monitor fat metabolism. In this study, we developed an advanced breath analyzer system designed to provide real-time monitoring of exercise-induced fat burning by analyzing volatile organic compounds (VOCs) present in both oral and alveolar breath. Acetone in exhaled breath and β-hydroxybutyric acid (BOHB) in the blood are both biomarkers closely linked to the metabolic fat burning process occurring in the liver, particularly after exercise. The breath analyzer utilizes a sensor array to detect VOC patterns, with the data analyzed using a one-dimensional convolutional neural network (1D CNN) for an accurate prediction of BOHB levels in the blood. We collected and analyzed 30 exhaled breath samples with our analyzer and blood samples for BOHB from participants before and after exercise. The results showed a strong correlation between sensor responses and BOHB levels, with Pearson correlation coefficients of 0.99 across different postexercise time points. The 1D CNN model effectively estimated BOHB concentrations, achieving Pearson coefficients of 0.96 for the training data set and 0.86 for the test data set. Additionally, our findings confirm that alveolar air samples, which contain metabolic byproducts from deeper in the lungs, offer more reliable data for fat burning analysis than oral air samples. This noninvasive, real-time breath monitoring tool offers a promising solution for individuals demanding to optimize their exercise routines and track metabolic health with high precision and accuracy.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
呼吸分析仪实时运动脂肪燃烧预测:口腔和肺泡呼吸洞察与CNN
随着肥胖和代谢紊乱的日益流行,对能够有效监测脂肪代谢的个性化设备产生了巨大的需求。在这项研究中,我们开发了一种先进的呼吸分析仪系统,旨在通过分析口腔和肺泡呼吸中存在的挥发性有机化合物(VOCs),实时监测运动引起的脂肪燃烧。呼出气体中的丙酮和血液中的β-羟基丁酸(BOHB)都是与肝脏代谢脂肪燃烧过程密切相关的生物标志物,尤其是在运动后。呼气分析仪利用传感器阵列来检测VOC模式,并使用一维卷积神经网络(1D CNN)分析数据,以准确预测血液中的BOHB水平。我们用分析仪收集并分析了30个呼气样本和参与者在运动前后的BOHB血液样本。结果显示,传感器反应与BOHB水平之间存在很强的相关性,在不同运动后时间点的Pearson相关系数为0.99。1D CNN模型有效地估计了BOHB浓度,训练数据集的Pearson系数为0.96,测试数据集的Pearson系数为0.86。此外,我们的研究结果证实,肺泡空气样本含有来自肺部深处的代谢副产物,为脂肪燃烧分析提供了比口腔空气样本更可靠的数据。这种无创、实时呼吸监测工具为需要优化锻炼习惯和高精度跟踪代谢健康的个人提供了一个有前途的解决方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
ACS Sensors
ACS Sensors Chemical Engineering-Bioengineering
CiteScore
14.50
自引率
3.40%
发文量
372
期刊介绍: ACS Sensors is a peer-reviewed research journal that focuses on the dissemination of new and original knowledge in the field of sensor science, particularly those that selectively sense chemical or biological species or processes. The journal covers a broad range of topics, including but not limited to biosensors, chemical sensors, gas sensors, intracellular sensors, single molecule sensors, cell chips, and microfluidic devices. It aims to publish articles that address conceptual advances in sensing technology applicable to various types of analytes or application papers that report on the use of existing sensing concepts in new ways or for new analytes.
期刊最新文献
Correction to: "Hollow Microstructure-Based Iontronic Pressure Sensors with High Sensitivity and High Linearity over a Broad Range". Bioinspired Hydrogel-Functionalized Microchannel-Gated Junction Field-Effect Transistor for Highly Sensitive Glutathione Detection. Explosive-Copper-Liposome-Based Click Amplification for Non-Invasive Quantification of Trace Biomarkers Microwave Cytometry with Machine Learning for Shape-Resolved Microplastic Detection Advancing Point-of-Care Testing for Helicobacter pylori toward CRISPR-Cas-Enabled Diagnostics
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1