Novel electroretinography devices to detect hydroxychloroquine retinopathy: study protocol for a diagnostic accuracy and feasibility study.

IF 2 Q2 OPHTHALMOLOGY BMJ Open Ophthalmology Pub Date : 2024-12-24 DOI:10.1136/bmjophth-2024-001898
Chan Ning Lee, Hatem A Wafa, George Murphy, James Galloway, Omar A Mahroo, Timothy L Jackson
{"title":"Novel electroretinography devices to detect hydroxychloroquine retinopathy: study protocol for a diagnostic accuracy and feasibility study.","authors":"Chan Ning Lee, Hatem A Wafa, George Murphy, James Galloway, Omar A Mahroo, Timothy L Jackson","doi":"10.1136/bmjophth-2024-001898","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Annual screening for hydroxychloroquine (HCQ) retinopathy is recommended, and electroretinography (ERG) is considered a gold-standard test, but there are screening shortfalls and standard ERG is burdensome and has limited availability. Newer, portable ERG devices using skin-based electrodes may increase screening capacity but need validation. This study aims to determine initial device accuracies and feasibility of further research.</p><p><strong>Methods and analysis: </strong>Prospective diagnostic device accuracy and feasibility study comparing novel ERG devices to standard screening tests. Three groups of 35 participants on HCQ, categorised by HCQ retinopathy (definite, possible and no retinopathy), and 35 healthy control participants, recruited by consecutive sampling, will have full field and multifocal ERG index tests, delivered using skin-contact electrodes by two devices-RETEval full-field and UTAS multifocal ERG, both manufactured by LKC Technologies (Gaithersburg, Maryland, USA), compared with spectral-domain optical coherence tomography and autofluorescence reference tests graded by two masked, independent retinal specialists. Eligible HCQ participants will either have diagnosed HCQ retinopathy or be eligible for screening per UK guidelines. Healthy control participants will have no prior HCQ exposure and be of similar age and sex to HCQ participants. Primary outcome is device-specific sensitivity and specificity. Secondary outcomes include the effect of dilation on device outputs, analysis of discriminatory waveforms, device acceptability and recruitment rate. Safety outcomes include adverse and serious adverse events and device events.</p><p><strong>Ethics and dissemination: </strong>Cambridge East ethics committee gave a favourable opinion (24/EE/0011, 23/02/2024). Results will be published in a peer-reviewed ophthalmology journal.</p><p><strong>Trial registration number: </strong>ClinicalTrials.gov NCT06035887.</p>","PeriodicalId":9286,"journal":{"name":"BMJ Open Ophthalmology","volume":"9 1","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2024-12-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11683940/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMJ Open Ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1136/bmjophth-2024-001898","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Annual screening for hydroxychloroquine (HCQ) retinopathy is recommended, and electroretinography (ERG) is considered a gold-standard test, but there are screening shortfalls and standard ERG is burdensome and has limited availability. Newer, portable ERG devices using skin-based electrodes may increase screening capacity but need validation. This study aims to determine initial device accuracies and feasibility of further research.

Methods and analysis: Prospective diagnostic device accuracy and feasibility study comparing novel ERG devices to standard screening tests. Three groups of 35 participants on HCQ, categorised by HCQ retinopathy (definite, possible and no retinopathy), and 35 healthy control participants, recruited by consecutive sampling, will have full field and multifocal ERG index tests, delivered using skin-contact electrodes by two devices-RETEval full-field and UTAS multifocal ERG, both manufactured by LKC Technologies (Gaithersburg, Maryland, USA), compared with spectral-domain optical coherence tomography and autofluorescence reference tests graded by two masked, independent retinal specialists. Eligible HCQ participants will either have diagnosed HCQ retinopathy or be eligible for screening per UK guidelines. Healthy control participants will have no prior HCQ exposure and be of similar age and sex to HCQ participants. Primary outcome is device-specific sensitivity and specificity. Secondary outcomes include the effect of dilation on device outputs, analysis of discriminatory waveforms, device acceptability and recruitment rate. Safety outcomes include adverse and serious adverse events and device events.

Ethics and dissemination: Cambridge East ethics committee gave a favourable opinion (24/EE/0011, 23/02/2024). Results will be published in a peer-reviewed ophthalmology journal.

Trial registration number: ClinicalTrials.gov NCT06035887.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
BMJ Open Ophthalmology
BMJ Open Ophthalmology OPHTHALMOLOGY-
CiteScore
3.40
自引率
4.20%
发文量
104
审稿时长
20 weeks
期刊最新文献
Efficacy and Safety of Prophylactic Agents in Prevention of Retinopathy of Prematurity: A Systematic Review and Meta-analysis of Randomised Controlled rials. Endoplasmic reticulum protein TXNDC5 modulates thyroid eye disease TGF-β1-induced myofibroblast transdifferentiation. Zoledronic acid as adjuvant therapy in neovascular age-related macular degeneration: a randomised controlled pilot study. Analysis of biofluid metabolomic profiles to the discovery of biomarkers in age-related macular degeneration. Novel electroretinography devices to detect hydroxychloroquine retinopathy: study protocol for a diagnostic accuracy and feasibility study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1