Construction of in situ modulated controlled growth of MOF-on-mof impedimetric assembly for the practical minimal level assessment of anti-mullerian hormone

IF 10.7 1区 生物学 Q1 BIOPHYSICS Biosensors and Bioelectronics Pub Date : 2024-12-30 DOI:10.1016/j.bios.2024.117113
Wan-Zheng Fang , Sathyadevi Palanisamy , Priya Vijayaraghavan , Chiao-Yun Chen , Shun-Long Weng , Chung-Shi Yang , Yun-Ming Wang
{"title":"Construction of in situ modulated controlled growth of MOF-on-mof impedimetric assembly for the practical minimal level assessment of anti-mullerian hormone","authors":"Wan-Zheng Fang ,&nbsp;Sathyadevi Palanisamy ,&nbsp;Priya Vijayaraghavan ,&nbsp;Chiao-Yun Chen ,&nbsp;Shun-Long Weng ,&nbsp;Chung-Shi Yang ,&nbsp;Yun-Ming Wang","doi":"10.1016/j.bios.2024.117113","DOIUrl":null,"url":null,"abstract":"<div><div>Anti-mullerian hormone (AMH) detection receives much attention since it is used as an ideal biomarker for quantitative assessment of ovarian reserve. The present study proposed a first report on the use of MOF-on-MOF as an electrochemical sensor for recognizing AMH in buffer and serum media. The MOF-on-MOF, MIL-88 B@UiO66NH<sub>2</sub> was synthesized by the internal extended growth method (IEGM) involving MIL-88 B on UiO66NH<sub>2</sub> by <em>in situ</em> method for the first time. MOF matrix could be established to form a three-dimensional (3D) core-shell hybrid unit using MOFs with distinct characteristics. The morphology, structural characteristics, and electrochemical performance of MIL-88 B@UiO66NH<sub>2</sub> were studied. It was successfully used for AMH sensing to demonstrate the detection performance of the internal extended growth method (IEGM) grown MIL-88 B@UiO66NH<sub>2</sub> made immunosensor. The electrochemical results indicated that MOF-on-MOF exhibited linear EIS response for AMH concentration varying from 100 ng/mL to 1 fg/mL. Further, the immunosensor displayed high specificity and sensitivity for AMH detection. The fabricated sensor attained a remarkable limit of detection (LOD) of 1.07 fg/mL and 0.82 fg/mL, when studied in PBS and 10% serum buffer media, respectively. The biosensor achieved the limit of quantification (LOQ) of 3.25 fg/mL and 2.5 fg/mL, respectively, when analyzed in PBS buffer and 10% serum buffer. The significant results emphasized that the fabricated biosensor holds a promising potential to act as an appropriate tool for rapid assessment of AMH levels.</div></div>","PeriodicalId":259,"journal":{"name":"Biosensors and Bioelectronics","volume":"272 ","pages":"Article 117113"},"PeriodicalIF":10.7000,"publicationDate":"2024-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosensors and Bioelectronics","FirstCategoryId":"1","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0956566324011205","RegionNum":1,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0

Abstract

Anti-mullerian hormone (AMH) detection receives much attention since it is used as an ideal biomarker for quantitative assessment of ovarian reserve. The present study proposed a first report on the use of MOF-on-MOF as an electrochemical sensor for recognizing AMH in buffer and serum media. The MOF-on-MOF, MIL-88 B@UiO66NH2 was synthesized by the internal extended growth method (IEGM) involving MIL-88 B on UiO66NH2 by in situ method for the first time. MOF matrix could be established to form a three-dimensional (3D) core-shell hybrid unit using MOFs with distinct characteristics. The morphology, structural characteristics, and electrochemical performance of MIL-88 B@UiO66NH2 were studied. It was successfully used for AMH sensing to demonstrate the detection performance of the internal extended growth method (IEGM) grown MIL-88 B@UiO66NH2 made immunosensor. The electrochemical results indicated that MOF-on-MOF exhibited linear EIS response for AMH concentration varying from 100 ng/mL to 1 fg/mL. Further, the immunosensor displayed high specificity and sensitivity for AMH detection. The fabricated sensor attained a remarkable limit of detection (LOD) of 1.07 fg/mL and 0.82 fg/mL, when studied in PBS and 10% serum buffer media, respectively. The biosensor achieved the limit of quantification (LOQ) of 3.25 fg/mL and 2.5 fg/mL, respectively, when analyzed in PBS buffer and 10% serum buffer. The significant results emphasized that the fabricated biosensor holds a promising potential to act as an appropriate tool for rapid assessment of AMH levels.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于抗苗勒管激素最低水平评估的MOF-on-mof阻抗体原位调控生长的构建。
抗苗勒管激素(Anti-mullerian hormone, AMH)检测作为一种理想的卵巢储备定量评价生物标志物,受到了广泛的关注。本研究首次报道了利用MOF-on-MOF作为一种电化学传感器来识别缓冲液和血清介质中的AMH。首次在UiO66NH2上原位合成了MIL-88 B的MOF-on-MOF, MIL-88 B@UiO66NH2。利用具有不同特性的MOF,可以建立MOF矩阵,形成三维核壳杂化单元。研究了MIL-88 B@UiO66NH2的形貌、结构特征和电化学性能。成功地用于AMH的检测,证明了内部扩展生长法(IEGM)生长的MIL-88 B@UiO66NH2制成的免疫传感器的检测性能。电化学结果表明,MOF-on-MOF对AMH浓度在100 ng/mL ~ 1 fg/mL范围内呈线性EIS响应。此外,该免疫传感器对AMH检测具有较高的特异性和敏感性。在PBS和10%血清缓冲液中,传感器的检出限分别为1.07 fg/mL和0.82 fg/mL。当在PBS缓冲液和10%血清缓冲液中分析时,生物传感器的定量限分别为3.25 fg/mL和2.5 fg/mL。重要的结果强调,制造的生物传感器具有良好的潜力,可作为快速评估AMH水平的适当工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Biosensors and Bioelectronics
Biosensors and Bioelectronics 工程技术-电化学
CiteScore
20.80
自引率
7.10%
发文量
1006
审稿时长
29 days
期刊介绍: Biosensors & Bioelectronics, along with its open access companion journal Biosensors & Bioelectronics: X, is the leading international publication in the field of biosensors and bioelectronics. It covers research, design, development, and application of biosensors, which are analytical devices incorporating biological materials with physicochemical transducers. These devices, including sensors, DNA chips, electronic noses, and lab-on-a-chip, produce digital signals proportional to specific analytes. Examples include immunosensors and enzyme-based biosensors, applied in various fields such as medicine, environmental monitoring, and food industry. The journal also focuses on molecular and supramolecular structures for enhancing device performance.
期刊最新文献
Editorial Board Supercapacitor-powered wearable biosensor for continuous lactate monitoring from sweat A self-powered biosensor with cascade amplification capability facilitates ultra-sensitive detection of microRNA biomarkers Highly integrated and compact transduction strategy for multidimensional sensing: Near infrared light mediated transmission of optical, electrical and visual signals for ovarian cancer marker assay. A HClO-activated BODIPY based ratiometric fluorescent probe with dual near-infrared channels for differentiating cancerous cells from normal cells and surgical guidance of tumor resection
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1