{"title":"Extended homogeneous field correction method based on oblique projection in OPM-MEG.","authors":"Fulong Wang, Fuzhi Cao, Yujie Ma, Ruochen Zhao, Ruonan Wang, Nan An, Min Xiang, Dawei Wang, Xiaolin Ning","doi":"10.1016/j.neuroimage.2024.120991","DOIUrl":null,"url":null,"abstract":"<p><p>Optically pumped magnetometer-based magnetoencephalography (OPM-MEG) is an novel non-invasive functional imaging technique that features more flexible sensor configurations and wearability; however, this also increases the requirement for environmental noise suppression. Subspace projection algorithms are widely used in MEG to suppress noise. However, in OPM-MEG systems with a limited number of channels, subspace projection methods that rely on spatial oversampling exhibit reduced performance. The homogeneous field correction (HFC) method resolves this problem by constructing a low-rank spatial model; however, it cannot address complex non-homogeneous noise. The spatiotemporal extended homogeneous field correction (teHFC) method uses multiple orthogonal projections to suppress disturbances. However, the signal and noise subspace are not completely orthogonal, limiting enhancement in the capabilities of the teHFC. Therefore, we propose an extended homogeneous field correction method based on oblique projection (opHFC), which overcomes the issue of non-orthogonality between the signal and noise subspace, enhancing the ability to suppress complex interferences. The opHFC constructs an oblique projection operator that divides the signals into internal and external components, eliminating complex interferences through temporal extension. We compared the opHFC with four benchmark methods by simulations and auditory and somatosensory evoked OPM-MEG experiments. The results demonstrate that opHFC provides superior noise suppression with minimal distortion, enhancing the signal quality at the sensor and source levels. Our method offers a novel approach to reducing interference in OPM-MEG systems, expanding their application scenarios, and providing high-quality signals for scientific research and clinical applications based on OPM-MEG.</p>","PeriodicalId":19299,"journal":{"name":"NeuroImage","volume":" ","pages":"120991"},"PeriodicalIF":4.7000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"NeuroImage","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.neuroimage.2024.120991","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/3 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"NEUROIMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Optically pumped magnetometer-based magnetoencephalography (OPM-MEG) is an novel non-invasive functional imaging technique that features more flexible sensor configurations and wearability; however, this also increases the requirement for environmental noise suppression. Subspace projection algorithms are widely used in MEG to suppress noise. However, in OPM-MEG systems with a limited number of channels, subspace projection methods that rely on spatial oversampling exhibit reduced performance. The homogeneous field correction (HFC) method resolves this problem by constructing a low-rank spatial model; however, it cannot address complex non-homogeneous noise. The spatiotemporal extended homogeneous field correction (teHFC) method uses multiple orthogonal projections to suppress disturbances. However, the signal and noise subspace are not completely orthogonal, limiting enhancement in the capabilities of the teHFC. Therefore, we propose an extended homogeneous field correction method based on oblique projection (opHFC), which overcomes the issue of non-orthogonality between the signal and noise subspace, enhancing the ability to suppress complex interferences. The opHFC constructs an oblique projection operator that divides the signals into internal and external components, eliminating complex interferences through temporal extension. We compared the opHFC with four benchmark methods by simulations and auditory and somatosensory evoked OPM-MEG experiments. The results demonstrate that opHFC provides superior noise suppression with minimal distortion, enhancing the signal quality at the sensor and source levels. Our method offers a novel approach to reducing interference in OPM-MEG systems, expanding their application scenarios, and providing high-quality signals for scientific research and clinical applications based on OPM-MEG.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于 OPM-MEG 中斜投影的扩展均质场校正方法。
基于光泵磁力仪的脑磁图(OPM-MEG)是一种新型的非侵入性功能成像技术,具有更灵活的传感器配置和可穿戴性;然而,这也增加了对环境噪声抑制的要求。子空间投影算法在MEG中被广泛应用于噪声抑制。然而,在通道数量有限的OPM-MEG系统中,依赖于空间过采样的子空间投影方法表现出性能下降。均匀场校正(HFC)方法通过构建低秩空间模型解决了这一问题;然而,它不能处理复杂的非均匀噪声。时空扩展均匀场校正(teHFC)方法利用多个正交投影来抑制干扰。然而,信号和噪声子空间不是完全正交的,限制了teHFC性能的增强。因此,我们提出了一种基于斜投影的扩展均匀场校正方法(opHFC),该方法克服了信号与噪声子空间之间的非正交性问题,增强了抑制复杂干扰的能力。opHFC构建一个斜投影算子,将信号分为内部和外部分量,通过时间扩展消除复杂的干扰。我们通过模拟实验、听觉和体感诱发的OPM-MEG实验,将opHFC与四种基准方法进行比较。结果表明,opHFC以最小的失真提供了优越的噪声抑制,提高了传感器和源级的信号质量。该方法为减少OPM-MEG系统的干扰,扩展其应用场景,并为基于OPM-MEG的科学研究和临床应用提供高质量的信号提供了新的途径。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
NeuroImage
NeuroImage 医学-核医学
CiteScore
11.30
自引率
10.50%
发文量
809
审稿时长
63 days
期刊介绍: NeuroImage, a Journal of Brain Function provides a vehicle for communicating important advances in acquiring, analyzing, and modelling neuroimaging data and in applying these techniques to the study of structure-function and brain-behavior relationships. Though the emphasis is on the macroscopic level of human brain organization, meso-and microscopic neuroimaging across all species will be considered if informative for understanding the aforementioned relationships.
期刊最新文献
Task-specific temporal prediction mechanisms revealed by motor and electroencephalographic indicators. A novel way to use cross-validation to measure connectivity by machine learning allows epilepsy surgery outcome prediction. Cardiorespiratory dynamics in the brain: Review on the significance of cardiovascular and respiratory correlates in functional MRI signal. Fast EEG/MEG BEM-based forward problem solution for high-resolution head models. Local structural-functional coupling with counterfactual explanations for epilepsy prediction.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1