Design of a compact, high-resolution velocity-map imaging spectrometer for attosecond spectroscopy.

IF 1.7 4区 工程技术 Q3 INSTRUMENTS & INSTRUMENTATION Review of Scientific Instruments Pub Date : 2025-01-01 DOI:10.1063/5.0240707
D Platzer, A Autuori, C Schouder, M Lejman, L Maëder, H J B Marroux, C Pothier, P Salières, L Poisson
{"title":"Design of a compact, high-resolution velocity-map imaging spectrometer for attosecond spectroscopy.","authors":"D Platzer, A Autuori, C Schouder, M Lejman, L Maëder, H J B Marroux, C Pothier, P Salières, L Poisson","doi":"10.1063/5.0240707","DOIUrl":null,"url":null,"abstract":"<p><p>We present the design of a VMI spectrometer optimized for attosecond spectroscopy in the 0-40 eV energy range. It is based on a compact three-electrode configuration where the lens shape, size, and material have been optimized using numerical simulations to improve the spectral resolution by a factor of ∼5 relative to the initial design [Eppink and Parker, Rev. Sci. Instrum. 68, 3477-3484 (1997)] while keeping a flat spectral response in the 10-40 eV range. The experimental performance is tested using an attosecond source based on high-order harmonic generation. A good agreement is observed between the measured and simulated spectral resolution. At low kinetic energy, the electrostatic lens remains the limiting factor, while the high energy range is mostly affected by the resolution of the camera objective.</p>","PeriodicalId":21111,"journal":{"name":"Review of Scientific Instruments","volume":"96 1","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Review of Scientific Instruments","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1063/5.0240707","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

Abstract

We present the design of a VMI spectrometer optimized for attosecond spectroscopy in the 0-40 eV energy range. It is based on a compact three-electrode configuration where the lens shape, size, and material have been optimized using numerical simulations to improve the spectral resolution by a factor of ∼5 relative to the initial design [Eppink and Parker, Rev. Sci. Instrum. 68, 3477-3484 (1997)] while keeping a flat spectral response in the 10-40 eV range. The experimental performance is tested using an attosecond source based on high-order harmonic generation. A good agreement is observed between the measured and simulated spectral resolution. At low kinetic energy, the electrostatic lens remains the limiting factor, while the high energy range is mostly affected by the resolution of the camera objective.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于阿秒光谱学的紧凑、高分辨率速度图成像光谱仪的设计。
我们设计了一个在0-40 eV能量范围内优化了阿秒光谱的VMI光谱仪。它基于紧凑的三电极配置,其中透镜形状、尺寸和材料已经使用数值模拟进行了优化,以相对于初始设计提高光谱分辨率约5倍[Eppink和Parker, Rev. Sci]。仪器学报,68,3477-3484(1997)],同时在10-40 eV范围内保持平坦的光谱响应。利用基于高次谐波产生的阿秒源测试了实验性能。实测的光谱分辨率和模拟的光谱分辨率有很好的一致性。在低动能下,静电透镜仍然是限制因素,而在高能量范围内,主要受相机物镜分辨率的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Review of Scientific Instruments
Review of Scientific Instruments 工程技术-物理:应用
CiteScore
3.00
自引率
12.50%
发文量
758
审稿时长
2.6 months
期刊介绍: Review of Scientific Instruments, is committed to the publication of advances in scientific instruments, apparatuses, and techniques. RSI seeks to meet the needs of engineers and scientists in physics, chemistry, and the life sciences.
期刊最新文献
Design and performance of an illumination-based hyperspectral laparoscopic system. Luminescence of bandpass dichroic filters within their transmission band can result in misinterpretation of experimental data. Improvements in optical metrology for high-performance variable-line-spacing x-ray gratings. Research on a valve-positioner pilot valve driven by a piezoelectric stack with self-sensing feedback. Stray light correction for measurements of comet 67P acquired by Rosetta's Visible and InfraRed Thermal Imaging Spectrometer, IR Mapping channel (VIRTIS-M-IR), based on inflight data.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1