Quantifying tear exchange during rigid contact lens wear using corneoscleral profilometry: A proof of concept study.

IF 2.8 3区 医学 Q1 OPHTHALMOLOGY Ophthalmic and Physiological Optics Pub Date : 2025-01-18 DOI:10.1111/opo.13450
Asif Iqbal, Damien Fisher, David Alonso-Caneiro, Michael J Collins, Stephen J Vincent
{"title":"Quantifying tear exchange during rigid contact lens wear using corneoscleral profilometry: A proof of concept study.","authors":"Asif Iqbal, Damien Fisher, David Alonso-Caneiro, Michael J Collins, Stephen J Vincent","doi":"10.1111/opo.13450","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Tear exchange during contact lens wear is essential for ocular surface integrity, facilitating debris removal, and maintaining corneal metabolism. Fluorophotometry and fluorogram methods are typically used to measure tear exchange, which require hardware modifications to a slit lamp biomicroscope. This manuscript introduces an alternative method using a corneoscleral profilometer, the Eye Surface Profiler (ESP), to quantify tear exchange during corneal and scleral rigid lens wear by assessing fluorescence intensity changes over time.</p><p><strong>Methods: </strong>As a proof of concept, a healthy participant wore a corneal and a scleral rigid lens on separate days. After lens application, 2% sodium fluorescein was instilled, and ESP images were captured at intervals over a 30-min period for corneal and a 90-min period for the scleral lens. Fluorescence intensity data were extracted and analysed using MATLAB, restricted to a region of interest centred on the contact lens. The fluorescence intensity was fitted with an exponential decay curve to quantify tear exchange.</p><p><strong>Results: </strong>Fluorescence intensity decreased over time for both lenses, with a faster decay rate being observed for the corneal lens. The scleral lens showed an initial ingress of fluorescein into the fluid reservoir, then a slow decay in fluorescence intensity due to limited tear exchange. The decay rate for the corneal lens was approximately four times faster than the scleral lens, with the time to reach 50% decay of ~42 min for the corneal lens compared to ~157 min for the scleral lens.</p><p><strong>Conclusion: </strong>A new method was developed to quantify tear exchange using a commercially available corneoscleral profilometer, offering a wider field of view than existing techniques. This approach has clinical potential in scleral lens practice for identifying landing zone misalignment and improving the understanding of post-lens tear dynamics, particularly in cases involving scleral lens modifications or patients experiencing midday fogging.</p>","PeriodicalId":19522,"journal":{"name":"Ophthalmic and Physiological Optics","volume":" ","pages":""},"PeriodicalIF":2.8000,"publicationDate":"2025-01-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ophthalmic and Physiological Optics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/opo.13450","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Tear exchange during contact lens wear is essential for ocular surface integrity, facilitating debris removal, and maintaining corneal metabolism. Fluorophotometry and fluorogram methods are typically used to measure tear exchange, which require hardware modifications to a slit lamp biomicroscope. This manuscript introduces an alternative method using a corneoscleral profilometer, the Eye Surface Profiler (ESP), to quantify tear exchange during corneal and scleral rigid lens wear by assessing fluorescence intensity changes over time.

Methods: As a proof of concept, a healthy participant wore a corneal and a scleral rigid lens on separate days. After lens application, 2% sodium fluorescein was instilled, and ESP images were captured at intervals over a 30-min period for corneal and a 90-min period for the scleral lens. Fluorescence intensity data were extracted and analysed using MATLAB, restricted to a region of interest centred on the contact lens. The fluorescence intensity was fitted with an exponential decay curve to quantify tear exchange.

Results: Fluorescence intensity decreased over time for both lenses, with a faster decay rate being observed for the corneal lens. The scleral lens showed an initial ingress of fluorescein into the fluid reservoir, then a slow decay in fluorescence intensity due to limited tear exchange. The decay rate for the corneal lens was approximately four times faster than the scleral lens, with the time to reach 50% decay of ~42 min for the corneal lens compared to ~157 min for the scleral lens.

Conclusion: A new method was developed to quantify tear exchange using a commercially available corneoscleral profilometer, offering a wider field of view than existing techniques. This approach has clinical potential in scleral lens practice for identifying landing zone misalignment and improving the understanding of post-lens tear dynamics, particularly in cases involving scleral lens modifications or patients experiencing midday fogging.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
定量泪液交换在硬性隐形眼镜佩戴期间使用角膜巩膜轮廓术:概念研究的证明。
导言:隐形眼镜佩戴过程中的泪液交换对于眼表完整性、促进碎片清除和维持角膜代谢至关重要。荧光光度法和荧光图法通常用于测量泪液交换,这需要对裂隙灯生物显微镜进行硬件修改。本文介绍了一种使用角膜巩膜轮廓仪的替代方法,即眼表面轮廓仪(ESP),通过评估荧光强度随时间的变化来量化角膜和巩膜刚性晶状体磨损期间的泪液交换。方法:作为概念的证明,一个健康的参与者在不同的日子佩戴角膜和巩膜刚性晶状体。应用晶状体后,注入2%荧光素钠,每隔30分钟采集角膜和90分钟巩膜晶状体的ESP图像。使用MATLAB提取和分析荧光强度数据,仅限于以隐形眼镜为中心的感兴趣区域。荧光强度用指数衰减曲线拟合,定量测定泪液交换。结果:两种晶状体的荧光强度随着时间的推移而下降,角膜晶状体的衰减速度更快。巩膜晶状体显示荧光素最初进入液体储层,然后由于有限的泪液交换,荧光强度缓慢衰减。角膜晶状体的衰减速度约为巩膜晶状体的4倍,达到50%的衰减时间为~42分钟,而巩膜晶状体为~157分钟。结论:我们开发了一种新的方法来量化泪液交换,使用市售的角膜巩膜轮廓仪,提供了比现有技术更广阔的视野。该方法在巩膜晶状体实践中具有临床潜力,可用于识别着落区错位和提高对晶状体后撕裂动力学的理解,特别是在涉及巩膜晶状体修饰或患者中午雾蒙蒙的情况下。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
5.10
自引率
13.80%
发文量
135
审稿时长
6-12 weeks
期刊介绍: Ophthalmic & Physiological Optics, first published in 1925, is a leading international interdisciplinary journal that addresses basic and applied questions pertinent to contemporary research in vision science and optometry. OPO publishes original research papers, technical notes, reviews and letters and will interest researchers, educators and clinicians concerned with the development, use and restoration of vision.
期刊最新文献
Evaluation of the perception of information from ChatGPT in myopia education: Perspectives of students and professionals. Authors' reply: Cross-population validation of the PreMO risk indicator for predicting myopia onset in children. Quantifying tear exchange during rigid contact lens wear using corneoscleral profilometry: A proof of concept study. Repeatability of lipid layer thickness using LipiView® following removal of contact lenses and its relationship to comfort. The repeatability of macular and peripapillary vessel density in participants with different severities of glaucoma.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1