{"title":"Comparison of external calibration and isotope dilution methods for iodine determination in foods by inductively coupled plasma mass spectrometry.","authors":"Juntima Photi, Premmin Srisakda, Tiyanun Jurkvon, Christophe Zeder, Kunchit Judprasong","doi":"10.1016/j.fochx.2024.102119","DOIUrl":null,"url":null,"abstract":"<p><p>This study sought to validate the external calibration curve (CAL) method for iodine analysis in 26 selected foods and then to compare the test result with the isotope dilution mass spectrometry (IDMS). Iodine was extracted by tetramethylammonium hydroxide (TMAH) and determined by ICP-MS using CAL and IDMS methods. The results showed that iodine determination using the IDMS method had higher precision than the CAL method (LOD of the method were 0.01 and 0.02 mg/kg, respectively). However, both methods showed good accuracy and precision for all SRM and the 26 food samples. Test results from both methods had a strong correlation (R<sup>2</sup> > 0.998) and no significant difference between the determination methods, even within test sample sectors based on the distribution in the AOAC food triangle (<i>p</i> > 0.970). <sup>129</sup>I spiked into the sample before or during alkaline extraction showed no significant difference in the test results (<i>p</i> = 0.989).</p>","PeriodicalId":12334,"journal":{"name":"Food Chemistry: X","volume":"25 ","pages":"102119"},"PeriodicalIF":6.5000,"publicationDate":"2024-12-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11751426/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Food Chemistry: X","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1016/j.fochx.2024.102119","RegionNum":1,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"CHEMISTRY, APPLIED","Score":null,"Total":0}
引用次数: 0
Abstract
This study sought to validate the external calibration curve (CAL) method for iodine analysis in 26 selected foods and then to compare the test result with the isotope dilution mass spectrometry (IDMS). Iodine was extracted by tetramethylammonium hydroxide (TMAH) and determined by ICP-MS using CAL and IDMS methods. The results showed that iodine determination using the IDMS method had higher precision than the CAL method (LOD of the method were 0.01 and 0.02 mg/kg, respectively). However, both methods showed good accuracy and precision for all SRM and the 26 food samples. Test results from both methods had a strong correlation (R2 > 0.998) and no significant difference between the determination methods, even within test sample sectors based on the distribution in the AOAC food triangle (p > 0.970). 129I spiked into the sample before or during alkaline extraction showed no significant difference in the test results (p = 0.989).
期刊介绍:
Food Chemistry: X, one of three Open Access companion journals to Food Chemistry, follows the same aims, scope, and peer-review process. It focuses on papers advancing food and biochemistry or analytical methods, prioritizing research novelty. Manuscript evaluation considers novelty, scientific rigor, field advancement, and reader interest. Excluded are studies on food molecular sciences or disease cure/prevention. Topics include food component chemistry, bioactives, processing effects, additives, contaminants, and analytical methods. The journal welcome Analytical Papers addressing food microbiology, sensory aspects, and more, emphasizing new methods with robust validation and applicability to diverse foods or regions.