{"title":"Comparison of Temporal Artery and Rectal Temperature Measurement During Cooling and Rewarming in Neonates Treated for Hypoxic Ischemic Encephalopathy.","authors":"Michelle LaBella, Karen Kelly, Kristen Carlin, Elaine Walsh","doi":"10.1097/ANC.0000000000001224","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Finding an accurate and simple method of thermometry in the neonatal intensive care unit is important. The temporal artery thermometer (TAT) has been recommended for all ages by the manufacturer; however, there is insufficient evidence for the use of TAT in infants, especially to detect hypothermia.</p><p><strong>Purpose: </strong>To assess the accuracy of the TAT in hypothermic neonates in comparison to a rectal thermometer.</p><p><strong>Methods: </strong>This study was a naturalistic, quantitative, and observational study. Temporal artery temperatures (using Exergen TemporalScanner 5000) were compared to rectal temperatures in critically ill infants in the neonatal intensive care unit undergoing therapeutic hypothermia for hypoxic ischemic encephalopathy. Temperatures were taken during a 72-hour cooling period at 33.5 °C and a 6-hour rewarming period to normothermia of 36.5 °C. Nineteen patients and 1280 temperature measurements were included in this study.</p><p><strong>Results: </strong>During the cooling period, TAT and rectal temperatures had a weak correlation (r = 0.34, P < .001). The correlation during the rewarming period was much stronger (r = 0.70, P < .001), indicating less variability in measures, but not agreement. On average, regardless of period, the TAT temperatures read 0.43 °C (95% confidence interval, 0.37-0.49, P < .001) warmer than the rectal temperatures. The cooling or warming period had no effect on this difference between temperatures.</p><p><strong>Implications for practice and research: </strong>This study found that temperatures obtained with a TAT are generally warmer than the accepted standard core rectal temperature in hypothermic neonates, and we do not recommend its use in critically ill neonates who require accurate temperature readings.</p>","PeriodicalId":48862,"journal":{"name":"Advances in Neonatal Care","volume":" ","pages":""},"PeriodicalIF":1.6000,"publicationDate":"2025-01-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Neonatal Care","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/ANC.0000000000001224","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"NURSING","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Finding an accurate and simple method of thermometry in the neonatal intensive care unit is important. The temporal artery thermometer (TAT) has been recommended for all ages by the manufacturer; however, there is insufficient evidence for the use of TAT in infants, especially to detect hypothermia.

Purpose: To assess the accuracy of the TAT in hypothermic neonates in comparison to a rectal thermometer.

Methods: This study was a naturalistic, quantitative, and observational study. Temporal artery temperatures (using Exergen TemporalScanner 5000) were compared to rectal temperatures in critically ill infants in the neonatal intensive care unit undergoing therapeutic hypothermia for hypoxic ischemic encephalopathy. Temperatures were taken during a 72-hour cooling period at 33.5 °C and a 6-hour rewarming period to normothermia of 36.5 °C. Nineteen patients and 1280 temperature measurements were included in this study.

Results: During the cooling period, TAT and rectal temperatures had a weak correlation (r = 0.34, P < .001). The correlation during the rewarming period was much stronger (r = 0.70, P < .001), indicating less variability in measures, but not agreement. On average, regardless of period, the TAT temperatures read 0.43 °C (95% confidence interval, 0.37-0.49, P < .001) warmer than the rectal temperatures. The cooling or warming period had no effect on this difference between temperatures.

Implications for practice and research: This study found that temperatures obtained with a TAT are generally warmer than the accepted standard core rectal temperature in hypothermic neonates, and we do not recommend its use in critically ill neonates who require accurate temperature readings.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.60
自引率
5.90%
发文量
101
期刊介绍: Advances in Neonatal Care takes a unique and dynamic approach to the original research and clinical practice articles it publishes. Addressing the practice challenges faced every day—caring for the 40,000-plus low-birth-weight infants in Level II and Level III NICUs each year—the journal promotes evidence-based care and improved outcomes for the tiniest patients and their families. Peer-reviewed editorial includes unique and detailed visual and teaching aids, such as Family Teaching Toolbox, Research to Practice, Cultivating Clinical Expertise, and Online Features. Each issue offers Continuing Education (CE) articles in both print and online formats.
期刊最新文献
Comparison of Temporal Artery and Rectal Temperature Measurement During Cooling and Rewarming in Neonates Treated for Hypoxic Ischemic Encephalopathy. Implementing Early Kangaroo Mother Care: A Quality Improvement Initiative. Outcomes Associated With Care Models for Neonates With Complex Medical Needs: A Scoping Review to Support Program Evaluation. Relationship Between Clinical Decision-Making and Moral Distress in Neonatal Intensive Care Unit Nurses: A Multicenter Cross-Sectional Correlational Descriptive Study. A NICU Postoperative Pain Management Improvement Project to Reduce Uncontrolled Pain and Improve Staff Satisfaction.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1