Biocompatible Heterogeneous Packaging and Laser-Assisted Fluid Interface Control for In Situ Sensor in Organ-on-a-Chip.

IF 3 3区 工程技术 Q2 CHEMISTRY, ANALYTICAL Micromachines Pub Date : 2024-12-30 DOI:10.3390/mi16010046
Yu-Hsuan Lin, Shing-Fung Lau, Yen-Pei Lu, Kuo-Cheng Huang, Chien-Fang Ding, Yu-Hsiang Tang, Hsin-Yi Tsai
{"title":"Biocompatible Heterogeneous Packaging and Laser-Assisted Fluid Interface Control for In Situ Sensor in Organ-on-a-Chip.","authors":"Yu-Hsuan Lin, Shing-Fung Lau, Yen-Pei Lu, Kuo-Cheng Huang, Chien-Fang Ding, Yu-Hsiang Tang, Hsin-Yi Tsai","doi":"10.3390/mi16010046","DOIUrl":null,"url":null,"abstract":"<p><p>The development of bionic organ-on-a-chip technology relies heavily on advancements in in situ sensors and biochip packaging. By integrating precise biological and fluid condition sensing with microfluidics and electronic components, long-term dynamic closed-loop culture systems can be achieved. This study aims to develop biocompatible heterogeneous packaging and laser surface modification techniques to enable the encapsulation of electronic components while minimizing their impact on fluid dynamics. Using a kidney-on-a-chip as a case study, a non-toxic packaging process and fluid interface control methods have been successfully developed. Experimentally, miniature pressure sensors and control circuit boards were encapsulated using parylene-C, a biocompatible material, to isolate biochemical fluids from electronic components. Ultraviolet laser processing was employed to fabricate structures on parylene-C. The results demonstrate that through precise control of processing parameters, the wettability of the material can be tuned freely within a contact angle range of 60° to 110°. Morphological observations and MTT assays confirmed that the material and the processing methods do not induce cytotoxicity. This technology will facilitate the packaging of various miniature electronic components and biochips in the future. Furthermore, laser processing enables rapid and precise control of interface conditions across different regions within the chip, demonstrating a high potential for customized mass production of biochips. The proposed innovations provide a solution for in situ sensing in organ-on-a-chip systems and advanced biochip packaging. We believe that the development of this technology is a critical step toward realizing the concept of \"organ twin\".</p>","PeriodicalId":18508,"journal":{"name":"Micromachines","volume":"16 1","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2024-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11767515/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Micromachines","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/mi16010046","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The development of bionic organ-on-a-chip technology relies heavily on advancements in in situ sensors and biochip packaging. By integrating precise biological and fluid condition sensing with microfluidics and electronic components, long-term dynamic closed-loop culture systems can be achieved. This study aims to develop biocompatible heterogeneous packaging and laser surface modification techniques to enable the encapsulation of electronic components while minimizing their impact on fluid dynamics. Using a kidney-on-a-chip as a case study, a non-toxic packaging process and fluid interface control methods have been successfully developed. Experimentally, miniature pressure sensors and control circuit boards were encapsulated using parylene-C, a biocompatible material, to isolate biochemical fluids from electronic components. Ultraviolet laser processing was employed to fabricate structures on parylene-C. The results demonstrate that through precise control of processing parameters, the wettability of the material can be tuned freely within a contact angle range of 60° to 110°. Morphological observations and MTT assays confirmed that the material and the processing methods do not induce cytotoxicity. This technology will facilitate the packaging of various miniature electronic components and biochips in the future. Furthermore, laser processing enables rapid and precise control of interface conditions across different regions within the chip, demonstrating a high potential for customized mass production of biochips. The proposed innovations provide a solution for in situ sensing in organ-on-a-chip systems and advanced biochip packaging. We believe that the development of this technology is a critical step toward realizing the concept of "organ twin".

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
芯片上器官原位传感器的生物相容性异质封装和激光辅助流体界面控制。
仿生器官芯片技术的发展在很大程度上依赖于原位传感器和生物芯片封装的进步。通过将精确的生物和流体状态传感与微流体和电子元件相结合,可以实现长期动态闭环培养系统。本研究旨在开发生物相容性异质封装和激光表面修饰技术,以实现电子元件的封装,同时最大限度地减少其对流体动力学的影响。以单片肾为例,成功开发了一种无毒封装工艺和流体界面控制方法。实验中,微型压力传感器和控制电路板用二甲苯- c(一种生物相容性材料)封装,从电子元件中分离生化流体。采用紫外激光加工技术在聚苯乙烯- c上制备结构。结果表明,通过对工艺参数的精确控制,材料的润湿性可以在60°~ 110°的接触角范围内自由调节。形态学观察和MTT实验证实,材料和处理方法不诱导细胞毒性。这项技术将有助于未来各种微型电子元件和生物芯片的封装。此外,激光加工可以快速精确地控制芯片内不同区域的界面条件,显示出定制大规模生产生物芯片的巨大潜力。提出的创新为器官芯片系统和先进的生物芯片封装中的原位传感提供了解决方案。我们相信,这项技术的发展是实现“器官双胞胎”概念的关键一步。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Micromachines
Micromachines NANOSCIENCE & NANOTECHNOLOGY-INSTRUMENTS & INSTRUMENTATION
CiteScore
5.20
自引率
14.70%
发文量
1862
审稿时长
16.31 days
期刊介绍: Micromachines (ISSN 2072-666X) is an international, peer-reviewed open access journal which provides an advanced forum for studies related to micro-scaled machines and micromachinery. It publishes reviews, regular research papers and short communications. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced.
期刊最新文献
Comparative Evaluation of Two Image-Analysis Software Platforms for Microfluidic Assessment of Red Blood Cell Deformability in Chronic Lymphocytic Leukemia. Germanium-on-Silicon Waveguide-Integrated Photodiode with Dual Optical Inputs for Datacenter Applications. Enhanced Fringing Field Micro-Moisture Sensor with Elements Optimization. Synthesis and Characterization of CNC/CNF/rGO Composite Films for Advanced Functional Applications. An Enhanced Q-Factor Cantilever Resonator in Viscous Liquids Using Strategic Perforation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1