Minghong Qiao, Li Chang, Zili Zhou, Sam Cheng Jun, Ling He, Jing Zhang
{"title":"A two-branch framework for blood pressure estimation using photoplethysmography signals with deep learning and clinical prior physiological knowledge.","authors":"Minghong Qiao, Li Chang, Zili Zhou, Sam Cheng Jun, Ling He, Jing Zhang","doi":"10.1088/1361-6579/adae50","DOIUrl":null,"url":null,"abstract":"<p><p><i>Objective.</i>This paper presents a novel dual-branch framework for estimating blood pressure (BP) using photoplethysmography (PPG) signals. The method combines deep learning with clinical prior knowledge and models different time periods (morning, afternoon, and evening) to achieve precise, cuffless BP estimation.<i>Approach.</i>Preprocessed single-channel PPG signals are input into two feature extraction branches. The first branch converts PPG dimensions to 2D and uses pre-trained Mobile Vision Transformer-v2 (MobileViTv2) and Visual Geometry Group19 (Vgg19) backbones to extract deep PPG features based on the different mechanisms of systolic blood pressure (SBP) and diastolic blood pressure (DBP) formation. The second branch calculates multi-dimensional feature parameters based on the relationship between PPG waveforms and factors affecting BP. We fuse the features from both branches and consider diurnal BP variations, using AutoML strategy to construct specific SBP and DBP estimation models for the different periods. The algorithm was developed on the human resting state PPG and BP dataset (HRSD) and validated on the MIMIC-IV dataset for generalization performance.<i>Main results.</i>The mean absolute error (MAE) for BP estimation is 6.42 mmHg SBP and 4.96 mmHg DBP in the morning, 4.84 mmHg (SBP) and 3.73 mmHg (DBP) in the afternoon, and 2.65 mmHg (SBP) and 2.56 mmHg (DBP) in the evening. Performance on the MIMIC-IV database was 4.34 mmHg (SBP) and 3.11 mmHg (DBP). The method meets the standards of the Association for the Advancement of Medical Instrumentation and achieves Grade A of the British Hypertension Society (BHS) standards.<i>Significance</i>. This indicates that it is an accurate and reliable non-invasive BP monitoring technology, applicable for continuous health monitoring and cardiovascular disease prevention.</p>","PeriodicalId":20047,"journal":{"name":"Physiological measurement","volume":" ","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2025-02-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physiological measurement","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1361-6579/adae50","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0
Abstract
Objective.This paper presents a novel dual-branch framework for estimating blood pressure (BP) using photoplethysmography (PPG) signals. The method combines deep learning with clinical prior knowledge and models different time periods (morning, afternoon, and evening) to achieve precise, cuffless BP estimation.Approach.Preprocessed single-channel PPG signals are input into two feature extraction branches. The first branch converts PPG dimensions to 2D and uses pre-trained Mobile Vision Transformer-v2 (MobileViTv2) and Visual Geometry Group19 (Vgg19) backbones to extract deep PPG features based on the different mechanisms of systolic blood pressure (SBP) and diastolic blood pressure (DBP) formation. The second branch calculates multi-dimensional feature parameters based on the relationship between PPG waveforms and factors affecting BP. We fuse the features from both branches and consider diurnal BP variations, using AutoML strategy to construct specific SBP and DBP estimation models for the different periods. The algorithm was developed on the human resting state PPG and BP dataset (HRSD) and validated on the MIMIC-IV dataset for generalization performance.Main results.The mean absolute error (MAE) for BP estimation is 6.42 mmHg SBP and 4.96 mmHg DBP in the morning, 4.84 mmHg (SBP) and 3.73 mmHg (DBP) in the afternoon, and 2.65 mmHg (SBP) and 2.56 mmHg (DBP) in the evening. Performance on the MIMIC-IV database was 4.34 mmHg (SBP) and 3.11 mmHg (DBP). The method meets the standards of the Association for the Advancement of Medical Instrumentation and achieves Grade A of the British Hypertension Society (BHS) standards.Significance. This indicates that it is an accurate and reliable non-invasive BP monitoring technology, applicable for continuous health monitoring and cardiovascular disease prevention.
期刊介绍:
Physiological Measurement publishes papers about the quantitative assessment and visualization of physiological function in clinical research and practice, with an emphasis on the development of new methods of measurement and their validation.
Papers are published on topics including:
applied physiology in illness and health
electrical bioimpedance, optical and acoustic measurement techniques
advanced methods of time series and other data analysis
biomedical and clinical engineering
in-patient and ambulatory monitoring
point-of-care technologies
novel clinical measurements of cardiovascular, neurological, and musculoskeletal systems.
measurements in molecular, cellular and organ physiology and electrophysiology
physiological modeling and simulation
novel biomedical sensors, instruments, devices and systems
measurement standards and guidelines.