Boj Friedrich Hoppe, Johannes Rueckel, Jan Rudolph, Nicola Fink, Simon Weidert, Wolf Hohlbein, Adrian Cavalcanti-Kußmaul, Lena Trappmann, Basel Munawwar, Jens Ricke, Bastian Oliver Sabel
{"title":"Automated spinopelvic measurements on radiographs with artificial intelligence: a multi-reader study.","authors":"Boj Friedrich Hoppe, Johannes Rueckel, Jan Rudolph, Nicola Fink, Simon Weidert, Wolf Hohlbein, Adrian Cavalcanti-Kußmaul, Lena Trappmann, Basel Munawwar, Jens Ricke, Bastian Oliver Sabel","doi":"10.1007/s11547-025-01957-5","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To develop an artificial intelligence (AI) algorithm for automated measurements of spinopelvic parameters on lateral radiographs and compare its performance to multiple experienced radiologists and surgeons.</p><p><strong>Methods: </strong>On lateral full-spine radiographs of 295 consecutive patients, a two-staged region-based convolutional neural network (R-CNN) was trained to detect anatomical landmarks and calculate thoracic kyphosis (TK), lumbar lordosis (LL), sacral slope (SS), and sagittal vertical axis (SVA). Performance was evaluated on 65 radiographs not used for training, which were measured independently by 6 readers (3 radiologists, 3 surgeons), and the median per measurement was set as the reference standard. Intraclass correlation coefficient (ICC), mean absolute error (MAE), and standard deviation (SD) were used for statistical analysis; while, ANOVA was used to search for significant differences between the AI and human readers.</p><p><strong>Results: </strong>Automatic measurements (AI) showed excellent correlation with the reference standard, with all ICCs within the range of the readers (TK: 0.92 [AI] vs. 0.85-0.96 [readers]; LL: 0.95 vs. 0.87-0.98; SS: 0.93 vs. 0.89-0.98; SVA: 1.00 vs. 0.99-1.00; all p < 0.001). Analysis of the MAE (± SD) revealed comparable results to the six readers (TK: 3.71° (± 4.24) [AI] v.s 1.86-5.88° (± 3.48-6.17) [readers]; LL: 4.53° ± 4.68 vs. 2.21-5.34° (± 2.60-7.38); SS: 4.56° (± 6.10) vs. 2.20-4.76° (± 3.15-7.37); SVA: 2.44 mm (± 3.93) vs. 1.22-2.79 mm (± 2.42-7.11)); while, ANOVA confirmed no significant difference between the errors of the AI and any human reader (all p > 0.05). Human reading time was on average 139 s per case (range: 86-231 s).</p><p><strong>Conclusion: </strong>Our AI algorithm provides spinopelvic measurements accurate within the variability of experienced readers, but with the potential to save time and increase reproducibility.</p>","PeriodicalId":20817,"journal":{"name":"Radiologia Medica","volume":" ","pages":""},"PeriodicalIF":9.7000,"publicationDate":"2025-01-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiologia Medica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s11547-025-01957-5","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: To develop an artificial intelligence (AI) algorithm for automated measurements of spinopelvic parameters on lateral radiographs and compare its performance to multiple experienced radiologists and surgeons.
Methods: On lateral full-spine radiographs of 295 consecutive patients, a two-staged region-based convolutional neural network (R-CNN) was trained to detect anatomical landmarks and calculate thoracic kyphosis (TK), lumbar lordosis (LL), sacral slope (SS), and sagittal vertical axis (SVA). Performance was evaluated on 65 radiographs not used for training, which were measured independently by 6 readers (3 radiologists, 3 surgeons), and the median per measurement was set as the reference standard. Intraclass correlation coefficient (ICC), mean absolute error (MAE), and standard deviation (SD) were used for statistical analysis; while, ANOVA was used to search for significant differences between the AI and human readers.
Results: Automatic measurements (AI) showed excellent correlation with the reference standard, with all ICCs within the range of the readers (TK: 0.92 [AI] vs. 0.85-0.96 [readers]; LL: 0.95 vs. 0.87-0.98; SS: 0.93 vs. 0.89-0.98; SVA: 1.00 vs. 0.99-1.00; all p < 0.001). Analysis of the MAE (± SD) revealed comparable results to the six readers (TK: 3.71° (± 4.24) [AI] v.s 1.86-5.88° (± 3.48-6.17) [readers]; LL: 4.53° ± 4.68 vs. 2.21-5.34° (± 2.60-7.38); SS: 4.56° (± 6.10) vs. 2.20-4.76° (± 3.15-7.37); SVA: 2.44 mm (± 3.93) vs. 1.22-2.79 mm (± 2.42-7.11)); while, ANOVA confirmed no significant difference between the errors of the AI and any human reader (all p > 0.05). Human reading time was on average 139 s per case (range: 86-231 s).
Conclusion: Our AI algorithm provides spinopelvic measurements accurate within the variability of experienced readers, but with the potential to save time and increase reproducibility.
期刊介绍:
Felice Perussia founded La radiologia medica in 1914. It is a peer-reviewed journal and serves as the official journal of the Italian Society of Medical and Interventional Radiology (SIRM). The primary purpose of the journal is to disseminate information related to Radiology, especially advancements in diagnostic imaging and related disciplines. La radiologia medica welcomes original research on both fundamental and clinical aspects of modern radiology, with a particular focus on diagnostic and interventional imaging techniques. It also covers topics such as radiotherapy, nuclear medicine, radiobiology, health physics, and artificial intelligence in the context of clinical implications. The journal includes various types of contributions such as original articles, review articles, editorials, short reports, and letters to the editor. With an esteemed Editorial Board and a selection of insightful reports, the journal is an indispensable resource for radiologists and professionals in related fields. Ultimately, La radiologia medica aims to serve as a platform for international collaboration and knowledge sharing within the radiological community.