Daher Antonio Queiroz, Mariana Itaborai Moreira Freitas, Kaden Thomas Ockey, Damian Jaewhan Lee, Fengyuan Zheng
{"title":"Reverse Torque and Wear of Internal Connections of Metal-Based Abutments Under Cyclic Loading.","authors":"Daher Antonio Queiroz, Mariana Itaborai Moreira Freitas, Kaden Thomas Ockey, Damian Jaewhan Lee, Fengyuan Zheng","doi":"10.1111/jerd.13425","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Evaluate the reverse torque values and wear of internal connections caused by metal-based zirconia abutments under cyclic loading.</p><p><strong>Material and methods: </strong>Thirty implants were divided into three groups (n = 10), based on connection systems: Interference-fit cone-screw (Cortical Master Flash MI Fit-MTA and Cortical Master Flash MI RP-MTB), and Internal hexagon (Cortical Titanium Master Connect AR-IH). Metal-based zirconia abutments were tightened into the implant, and zirconia crowns were bonded using resin cement. All specimens underwent cyclic loading at 300 N and 9 Hz for 1,000,000 cycles. Reverse torques were assessed postloading, and wear was analyzed using scanning electron microscopy (SEM). Statistical analysis employed one-way ANOVA for reverse torque and wear values, with significant differences assessed via the Tukey test (α = 0.05).</p><p><strong>Results: </strong>Significant differences in reverse torque values were found among groups: MTA (24.9 N), MTB (24.1 N), and IH (14.4 N). The IH group showed higher mean wear values on the tension side (121.0) and compression side (112.6), with a wear difference of 8.4.</p><p><strong>Conclusion: </strong>The interference-fit cone-screw abutments demonstrated significantly reduced torque loss and morphology after cyclic loading, reflecting enhanced performance.</p><p><strong>Clinical significance: </strong>Although the stability of the metal base zirconia abutments to the implants was accurate, clinicians should be cautious about torque loss and more wear when using internal hexagon connections.</p>","PeriodicalId":15988,"journal":{"name":"Journal of Esthetic and Restorative Dentistry","volume":" ","pages":""},"PeriodicalIF":3.2000,"publicationDate":"2025-01-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Esthetic and Restorative Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/jerd.13425","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: Evaluate the reverse torque values and wear of internal connections caused by metal-based zirconia abutments under cyclic loading.
Material and methods: Thirty implants were divided into three groups (n = 10), based on connection systems: Interference-fit cone-screw (Cortical Master Flash MI Fit-MTA and Cortical Master Flash MI RP-MTB), and Internal hexagon (Cortical Titanium Master Connect AR-IH). Metal-based zirconia abutments were tightened into the implant, and zirconia crowns were bonded using resin cement. All specimens underwent cyclic loading at 300 N and 9 Hz for 1,000,000 cycles. Reverse torques were assessed postloading, and wear was analyzed using scanning electron microscopy (SEM). Statistical analysis employed one-way ANOVA for reverse torque and wear values, with significant differences assessed via the Tukey test (α = 0.05).
Results: Significant differences in reverse torque values were found among groups: MTA (24.9 N), MTB (24.1 N), and IH (14.4 N). The IH group showed higher mean wear values on the tension side (121.0) and compression side (112.6), with a wear difference of 8.4.
Conclusion: The interference-fit cone-screw abutments demonstrated significantly reduced torque loss and morphology after cyclic loading, reflecting enhanced performance.
Clinical significance: Although the stability of the metal base zirconia abutments to the implants was accurate, clinicians should be cautious about torque loss and more wear when using internal hexagon connections.
期刊介绍:
The Journal of Esthetic and Restorative Dentistry (JERD) is the longest standing peer-reviewed journal devoted solely to advancing the knowledge and practice of esthetic dentistry. Its goal is to provide the very latest evidence-based information in the realm of contemporary interdisciplinary esthetic dentistry through high quality clinical papers, sound research reports and educational features.
The range of topics covered in the journal includes:
- Interdisciplinary esthetic concepts
- Implants
- Conservative adhesive restorations
- Tooth Whitening
- Prosthodontic materials and techniques
- Dental materials
- Orthodontic, periodontal and endodontic esthetics
- Esthetics related research
- Innovations in esthetics