Bone Health Deterioration in Transfemoral Prosthetic Users: An Analytical Biomechanical Explanation

IF 2.2 4区 医学 Q3 ENGINEERING, BIOMEDICAL International Journal for Numerical Methods in Biomedical Engineering Pub Date : 2025-02-03 DOI:10.1002/cnm.70014
Jose L. Zavaleta-Ruiz, Matthew J. Major, Pankaj Pankaj
{"title":"Bone Health Deterioration in Transfemoral Prosthetic Users: An Analytical Biomechanical Explanation","authors":"Jose L. Zavaleta-Ruiz,&nbsp;Matthew J. Major,&nbsp;Pankaj Pankaj","doi":"10.1002/cnm.70014","DOIUrl":null,"url":null,"abstract":"<p>There is a five-decade recorded history indicating that persons with transfemoral amputation experience bone loss in their amputated femur at levels seen in bedridden and post-menopausal individuals, irrespective of age or mobility levels. We used computer simulation to recreate the mechanical environment created by the mechanical design of a prosthetic device in the surviving femur of individuals with transfemoral amputations. Finite element models of gait instances were developed from the hip joint computerized tomography scan of a subject along with a coupled ischial containment prosthetic socket fitted as per standard clinical guidelines. Accompanying mirror models, assembled similarly but without the prosthetic socket were used for stimulus comparison. Simulation showed that more than 90% of the trabecular bone volume in the amputated femur with an ischial containment socket registered compressive strain magnitudes below 300με. These strain magnitudes are below the threshold for bone maintenance as per mechanotransduction theory (i.e., they lie within the disuse window). Only 50% of the bone was in the disuse window for the mirror model for the gait instances considered. These results are consistent with reported in vivo evidence which shows that transfemoral prosthesis users may lose bone mass irrespective of age or mobility levels when using traditional socket designs. Clinically, this study shows that prosthetic sockets that support load through the ischium alter the kinetic chain and preclude application of mechanical stimulus that sustains healthy levels of bone mass in the proximal femur. The study also shows that femur length, prosthetic alignment and tissue tone influence this stimulus.</p>","PeriodicalId":50349,"journal":{"name":"International Journal for Numerical Methods in Biomedical Engineering","volume":"41 2","pages":""},"PeriodicalIF":2.2000,"publicationDate":"2025-02-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/cnm.70014","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal for Numerical Methods in Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/cnm.70014","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

There is a five-decade recorded history indicating that persons with transfemoral amputation experience bone loss in their amputated femur at levels seen in bedridden and post-menopausal individuals, irrespective of age or mobility levels. We used computer simulation to recreate the mechanical environment created by the mechanical design of a prosthetic device in the surviving femur of individuals with transfemoral amputations. Finite element models of gait instances were developed from the hip joint computerized tomography scan of a subject along with a coupled ischial containment prosthetic socket fitted as per standard clinical guidelines. Accompanying mirror models, assembled similarly but without the prosthetic socket were used for stimulus comparison. Simulation showed that more than 90% of the trabecular bone volume in the amputated femur with an ischial containment socket registered compressive strain magnitudes below 300με. These strain magnitudes are below the threshold for bone maintenance as per mechanotransduction theory (i.e., they lie within the disuse window). Only 50% of the bone was in the disuse window for the mirror model for the gait instances considered. These results are consistent with reported in vivo evidence which shows that transfemoral prosthesis users may lose bone mass irrespective of age or mobility levels when using traditional socket designs. Clinically, this study shows that prosthetic sockets that support load through the ischium alter the kinetic chain and preclude application of mechanical stimulus that sustains healthy levels of bone mass in the proximal femur. The study also shows that femur length, prosthetic alignment and tissue tone influence this stimulus.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
International Journal for Numerical Methods in Biomedical Engineering
International Journal for Numerical Methods in Biomedical Engineering ENGINEERING, BIOMEDICAL-MATHEMATICAL & COMPUTATIONAL BIOLOGY
CiteScore
4.50
自引率
9.50%
发文量
103
审稿时长
3 months
期刊介绍: All differential equation based models for biomedical applications and their novel solutions (using either established numerical methods such as finite difference, finite element and finite volume methods or new numerical methods) are within the scope of this journal. Manuscripts with experimental and analytical themes are also welcome if a component of the paper deals with numerical methods. Special cases that may not involve differential equations such as image processing, meshing and artificial intelligence are within the scope. Any research that is broadly linked to the wellbeing of the human body, either directly or indirectly, is also within the scope of this journal.
期刊最新文献
Numerical Simulation of Fluid–Structure Interaction in Axillary Artery Venoarterial Extracorporeal Membrane Oxygenation for Heart Failure Patients Issue Information Coupled Finite Element Model of the Middle and Inner Ear as Virtual Test Environment for Stapes Surgery Computation of Viscoelastic Shear Shock Waves Using Finite Volume Schemes With Artificial Compressibility Bone Health Deterioration in Transfemoral Prosthetic Users: An Analytical Biomechanical Explanation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1