Xiaolin Wu , Kaspar M.B. Jansen , Jos J.M. Westenberg , Hildo J. Lamb , Saša Kenjereš
{"title":"Aortic strain, flow pattern and wall shear stress in a patient-specific compliant aorta replica using Shake-the-Box","authors":"Xiaolin Wu , Kaspar M.B. Jansen , Jos J.M. Westenberg , Hildo J. Lamb , Saša Kenjereš","doi":"10.1016/j.medengphy.2024.104263","DOIUrl":null,"url":null,"abstract":"<div><div>High-fidelity <em>in vitro</em> flow simulator in combination with high-dimensional flow visualization techniques can offer precise and comprehensive evaluation of aortic hemodynamics. However, it is particularly challenging to create a fully transparent aorta replica that faithfully mimics the aortic curvature and stiffness. In this study, we successfully manufactured a patient-specific compliant aorta phantom with a dilated ascending aorta that can be used <em>in vitro</em> hemodynamic study. We conducted pulsatile flow measurement on the deformable aorta replica using advanced 4D particle tracking velocimetry – Shake-the-Box. The aortic distensibility, circumferential strain, flow pattern, wall shear stress (WSS), and turbulent kinetic energy were assessed. Furthermore, the peak velocity field and WSS distribution were compared to <em>in vivo</em> MRI measurements. We found that the distensibility and circumferential strain of our aortic replica fell within the physiological range of young patients. The aortic diameter changed as much as 5.4 mm (42 %) in a cardiac cycle and the aortic distensibility was 9.9 × 10<sup>–3</sup> mmHg<sup>-1</sup>. In addition, the obtained flow pattern and WSS distribution were found in a good agreement with <em>in vivo</em> MRI measurement. In conclusion, the compliant aorta phantom replicated the aortic wall material well. It also faithfully simulated the aortic flow and near-wall hemodynamics. The relatively large lumen dimension change (5.4 mm) in a cardiac cycle suggests the necessity of considering wall deformation in aortic flow simulations. We propose employing this approach for future studies, such as medical treatment training, validation of <em>in silico</em> fluid-structure interaction models, or as a complement to <em>in vivo</em> measurements.</div></div>","PeriodicalId":49836,"journal":{"name":"Medical Engineering & Physics","volume":"135 ","pages":"Article 104263"},"PeriodicalIF":1.7000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Engineering & Physics","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1350453324001644","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
High-fidelity in vitro flow simulator in combination with high-dimensional flow visualization techniques can offer precise and comprehensive evaluation of aortic hemodynamics. However, it is particularly challenging to create a fully transparent aorta replica that faithfully mimics the aortic curvature and stiffness. In this study, we successfully manufactured a patient-specific compliant aorta phantom with a dilated ascending aorta that can be used in vitro hemodynamic study. We conducted pulsatile flow measurement on the deformable aorta replica using advanced 4D particle tracking velocimetry – Shake-the-Box. The aortic distensibility, circumferential strain, flow pattern, wall shear stress (WSS), and turbulent kinetic energy were assessed. Furthermore, the peak velocity field and WSS distribution were compared to in vivo MRI measurements. We found that the distensibility and circumferential strain of our aortic replica fell within the physiological range of young patients. The aortic diameter changed as much as 5.4 mm (42 %) in a cardiac cycle and the aortic distensibility was 9.9 × 10–3 mmHg-1. In addition, the obtained flow pattern and WSS distribution were found in a good agreement with in vivo MRI measurement. In conclusion, the compliant aorta phantom replicated the aortic wall material well. It also faithfully simulated the aortic flow and near-wall hemodynamics. The relatively large lumen dimension change (5.4 mm) in a cardiac cycle suggests the necessity of considering wall deformation in aortic flow simulations. We propose employing this approach for future studies, such as medical treatment training, validation of in silico fluid-structure interaction models, or as a complement to in vivo measurements.
期刊介绍:
Medical Engineering & Physics provides a forum for the publication of the latest developments in biomedical engineering, and reflects the essential multidisciplinary nature of the subject. The journal publishes in-depth critical reviews, scientific papers and technical notes. Our focus encompasses the application of the basic principles of physics and engineering to the development of medical devices and technology, with the ultimate aim of producing improvements in the quality of health care.Topics covered include biomechanics, biomaterials, mechanobiology, rehabilitation engineering, biomedical signal processing and medical device development. Medical Engineering & Physics aims to keep both engineers and clinicians abreast of the latest applications of technology to health care.