Application of novel oligomeric Co(II) complexes of 4,4′-bipyridine and 1,10-phenanthroline modified glassy carbon electrode for differential pulse voltammetric determination of ciprofloxacin
{"title":"Application of novel oligomeric Co(II) complexes of 4,4′-bipyridine and 1,10-phenanthroline modified glassy carbon electrode for differential pulse voltammetric determination of ciprofloxacin","authors":"Mezgebu Biresaw , Adane Kassa , Getinet Tamiru Tigineh , Atakilt Abebe","doi":"10.1016/j.sbsr.2024.100721","DOIUrl":null,"url":null,"abstract":"<div><div>Two new oligomer mixed ligand complexes, comprising 21 ([Co<sub>21</sub>(phen)<sub>42</sub>(bipy)<sub>21</sub>]Cl<sub>42</sub> (C2)) and 100 monomer units ([Co<sub>100</sub>(phen)<sub>200</sub>(bipy)<sub>100</sub>]Cl<sub>200</sub> (C3)) were synthesized. These complexes, designated as [Co<sub>21</sub>(phen)<sub>42</sub>(bipy)<sub>21</sub>]Cl<sub>42</sub> (C2) and [Co<sub>100</sub>(phen)<sub>200</sub>(bipy)<sub>100</sub>]Cl<sub>200</sub> (C3), were employed for the modification of a glassy carbon electrode (GCE) to detect ciprofloxacin (CPF) in tablet formulations and human urine samples. By potentiodynamic deposition, the modified electrodes (poly(C2)/GCE) and (poly(C3)/GCE) were prepared, forming a conductive electroactive film on the GCE surface. The modified electrodes were characterized using cyclic voltammetry and electrochemical impedance spectroscopy, which revealed an increased effective surface area and a significant reduction in charge transfer resistance of the electrode. An oxidative peak at a lower potential with a six-fold increase in peak current was observed at the poly(C2)/GCE. The absence of a reductive peak in the reverse scan indicated the irreversibility of the electrochemical oxidation of CPF. The correlation coefficient between the peak current and the square root of the scan rate indicated that CPF oxidation at the poly(C2)/GCE was primarily controlled by diffusion mass transport. With a detection limit of 3.4 × 10<sup>−9</sup> M, the voltammetric current response of CPF at the poly(C2)/GCE under optimal circumstances showed a linear trend with concentrations ranging from 5.0 × 10<sup>−8</sup> to 2.0 × 10<sup>−4</sup> M. It was discovered that the CPF levels in the examined tablet brands fell between 98.35 % and 101.30 % of their stated ranges. The recovery results for tablet and urine samples ranged from 99.44 % to 99.95 % and 99.25 % to 100.51 %, respectively, with interference recovery showing an error of less than 4.73 %. When it came to determining CPF in tablet formulations and human urine samples, the new approach outperformed recently published voltammetric methods. This superiority can be attributed to the simplicity of the electrode modification step, the lowest limit of detection, and a reasonably wide linear dynamic range.</div></div>","PeriodicalId":424,"journal":{"name":"Sensing and Bio-Sensing Research","volume":"47 ","pages":"Article 100721"},"PeriodicalIF":5.4000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensing and Bio-Sensing Research","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S221418042400103X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Two new oligomer mixed ligand complexes, comprising 21 ([Co21(phen)42(bipy)21]Cl42 (C2)) and 100 monomer units ([Co100(phen)200(bipy)100]Cl200 (C3)) were synthesized. These complexes, designated as [Co21(phen)42(bipy)21]Cl42 (C2) and [Co100(phen)200(bipy)100]Cl200 (C3), were employed for the modification of a glassy carbon electrode (GCE) to detect ciprofloxacin (CPF) in tablet formulations and human urine samples. By potentiodynamic deposition, the modified electrodes (poly(C2)/GCE) and (poly(C3)/GCE) were prepared, forming a conductive electroactive film on the GCE surface. The modified electrodes were characterized using cyclic voltammetry and electrochemical impedance spectroscopy, which revealed an increased effective surface area and a significant reduction in charge transfer resistance of the electrode. An oxidative peak at a lower potential with a six-fold increase in peak current was observed at the poly(C2)/GCE. The absence of a reductive peak in the reverse scan indicated the irreversibility of the electrochemical oxidation of CPF. The correlation coefficient between the peak current and the square root of the scan rate indicated that CPF oxidation at the poly(C2)/GCE was primarily controlled by diffusion mass transport. With a detection limit of 3.4 × 10−9 M, the voltammetric current response of CPF at the poly(C2)/GCE under optimal circumstances showed a linear trend with concentrations ranging from 5.0 × 10−8 to 2.0 × 10−4 M. It was discovered that the CPF levels in the examined tablet brands fell between 98.35 % and 101.30 % of their stated ranges. The recovery results for tablet and urine samples ranged from 99.44 % to 99.95 % and 99.25 % to 100.51 %, respectively, with interference recovery showing an error of less than 4.73 %. When it came to determining CPF in tablet formulations and human urine samples, the new approach outperformed recently published voltammetric methods. This superiority can be attributed to the simplicity of the electrode modification step, the lowest limit of detection, and a reasonably wide linear dynamic range.
期刊介绍:
Sensing and Bio-Sensing Research is an open access journal dedicated to the research, design, development, and application of bio-sensing and sensing technologies. The editors will accept research papers, reviews, field trials, and validation studies that are of significant relevance. These submissions should describe new concepts, enhance understanding of the field, or offer insights into the practical application, manufacturing, and commercialization of bio-sensing and sensing technologies.
The journal covers a wide range of topics, including sensing principles and mechanisms, new materials development for transducers and recognition components, fabrication technology, and various types of sensors such as optical, electrochemical, mass-sensitive, gas, biosensors, and more. It also includes environmental, process control, and biomedical applications, signal processing, chemometrics, optoelectronic, mechanical, thermal, and magnetic sensors, as well as interface electronics. Additionally, it covers sensor systems and applications, µTAS (Micro Total Analysis Systems), development of solid-state devices for transducing physical signals, and analytical devices incorporating biological materials.