Indoor pollution of funeral homes and potential health risk of workers: A case study in central China

IF 7.6 1区 工程技术 Q1 CONSTRUCTION & BUILDING TECHNOLOGY Building and Environment Pub Date : 2025-03-15 Epub Date: 2025-02-05 DOI:10.1016/j.buildenv.2025.112677
Jinjun Ye , Zhengtao Ai , Lup Wai Chew
{"title":"Indoor pollution of funeral homes and potential health risk of workers: A case study in central China","authors":"Jinjun Ye ,&nbsp;Zhengtao Ai ,&nbsp;Lup Wai Chew","doi":"10.1016/j.buildenv.2025.112677","DOIUrl":null,"url":null,"abstract":"<div><div>Funeral services play a vital role in the social fabric, yet the pollutants and occupational exposures in the indoor environment of funeral homes remain unknown. To address this gap, this study conducted a comprehensive screening of pollutants, including organic and inorganic chemicals, as well as bacteria, in the dressing-morgue and cremation room of a funeral home in Changsha. It was found that 151 VOCs and 29 SVOCs were detected in the dressing-morgue, while 129 VOCs and 38 SVOCs in the cremation room. Notably, these organic chemicals demonstrated saturation levels (double bond equivalent (DBE) = 3.3-3.4) that fell between outdoor air chemicals (DBE = 7.3) and those released from corpses (DBE = 1.5). In the dressing-morgue and cremation room, 4 and 3 chemicals posed a non-cancer risk (HQ) above the safety threshold (1.0), respectively; and 8 and 6 chemicals posed an incremental lifetime cancer risk (ILCR) above the safety threshold (1.0 × 10<sup>-6</sup>), respectively. In the dressing-morgue, the highest HQ and ILCR were 145.0 (Acrolein) and 1.2 × 10<sup>-4</sup> (Cobalt), respectively; while in the cremation room, there were 65.0 (Acrolein) and 2.0 × 10<sup>-5</sup> (1,2-Dibromoethane), respectively. In terms of bacteria, Alpha and Beta diversity analysis indicated that airborne bacterial community in both workspaces were highly similar, while surface-adhered bacteria displayed higher diversity. In both workspaces, Bacteroides was the predominant airborne pathogenic genus. These findings present the first disclosure of pollution conditions in funeral homes, aiming to raise societal awareness about the occupational exposure and to motivate the development of evidence-based solutions.</div></div>","PeriodicalId":9273,"journal":{"name":"Building and Environment","volume":"272 ","pages":"Article 112677"},"PeriodicalIF":7.6000,"publicationDate":"2025-03-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Building and Environment","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0360132325001593","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/2/5 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Funeral services play a vital role in the social fabric, yet the pollutants and occupational exposures in the indoor environment of funeral homes remain unknown. To address this gap, this study conducted a comprehensive screening of pollutants, including organic and inorganic chemicals, as well as bacteria, in the dressing-morgue and cremation room of a funeral home in Changsha. It was found that 151 VOCs and 29 SVOCs were detected in the dressing-morgue, while 129 VOCs and 38 SVOCs in the cremation room. Notably, these organic chemicals demonstrated saturation levels (double bond equivalent (DBE) = 3.3-3.4) that fell between outdoor air chemicals (DBE = 7.3) and those released from corpses (DBE = 1.5). In the dressing-morgue and cremation room, 4 and 3 chemicals posed a non-cancer risk (HQ) above the safety threshold (1.0), respectively; and 8 and 6 chemicals posed an incremental lifetime cancer risk (ILCR) above the safety threshold (1.0 × 10-6), respectively. In the dressing-morgue, the highest HQ and ILCR were 145.0 (Acrolein) and 1.2 × 10-4 (Cobalt), respectively; while in the cremation room, there were 65.0 (Acrolein) and 2.0 × 10-5 (1,2-Dibromoethane), respectively. In terms of bacteria, Alpha and Beta diversity analysis indicated that airborne bacterial community in both workspaces were highly similar, while surface-adhered bacteria displayed higher diversity. In both workspaces, Bacteroides was the predominant airborne pathogenic genus. These findings present the first disclosure of pollution conditions in funeral homes, aiming to raise societal awareness about the occupational exposure and to motivate the development of evidence-based solutions.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
殡仪馆室内污染与工作人员潜在健康风险:以华中地区为例
殡葬服务在社会结构中发挥着至关重要的作用,但殡仪馆室内环境中的污染物和职业暴露仍然未知。为了解决这一差距,本研究对长沙一家殡仪馆的太平间和火葬室的污染物进行了全面的筛选,包括有机和无机化学物质,以及细菌。换衣间检测到VOCs 151种、SVOCs 29种,火化室检测到VOCs 129种、SVOCs 38种。值得注意的是,这些有机化学物质的饱和水平(双键当量(DBE) = 3.3-3.4)介于室外空气化学物质(DBE = 7.3)和尸体释放的化学物质(DBE = 1.5)之间。在梳妆间和火葬室中,有4种和3种化学物质的非致癌风险(HQ)分别高于安全阈值(1.0);8种和6种化学物质的终生致癌风险(ILCR)分别高于安全阈值(1.0 × 10-6)。在敷料-停尸房,最高的HQ和ILCR分别为145.0(丙烯醛)和1.2 × 10-4(钴);火化室丙烯醛含量为65.0,二溴乙烷含量为2.0 × 10-5。在细菌方面,α和β多样性分析表明,两个工作空间的空气细菌群落高度相似,而表面粘附细菌的多样性更高。在这两个工作场所,拟杆菌属是主要的空气传播致病性属。这些发现首次披露了殡仪馆的污染状况,旨在提高社会对职业暴露的认识,并推动循证解决方案的发展。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Building and Environment
Building and Environment 工程技术-工程:环境
CiteScore
12.50
自引率
23.00%
发文量
1130
审稿时长
27 days
期刊介绍: Building and Environment, an international journal, is dedicated to publishing original research papers, comprehensive review articles, editorials, and short communications in the fields of building science, urban physics, and human interaction with the indoor and outdoor built environment. The journal emphasizes innovative technologies and knowledge verified through measurement and analysis. It covers environmental performance across various spatial scales, from cities and communities to buildings and systems, fostering collaborative, multi-disciplinary research with broader significance.
期刊最新文献
A calculation model for particulate matter concentration on subway platform based on 2D dimensionality reduction and equivalent emission rates Multi-indicator performance prediction in residential buildings: A multimodal fusion method based on cross-attention Automated IoT-based prototype for real-time equipment control and equivalent CO₂ emission monitoring Ten questions concerning digital transformation for a circular built environment Evaluation of the mechanism for enhanced particle and VOC removal using needlepoint bipolar ionization technology
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1